Would like to see the whole chimney but that doesn't cut it around here. Stucco to the shingles laves no room for replacement or repair. Also it appears the stucco installer cut the ear off on the corner.

Way we do it is we pre-flash the wall with counter held up off the roof 1" so the step flashing can be slid up under it. Then barriers go over the pre-flash. which has about 1/2" gap off the surface substrate. Siding installers go first then roofers when they are finished. Saves mess on the finished roof that way.

Heck with it, this picture will explain.................