Not intended for Use?
At an inspection yesterday I came across this. My concern was that the four beams being used as the lintel were not securely attached to the post.
I wrote "Observed that lintel was only secured to post by four nails which shear strength may not be adequate for the purpose. Concern for improper connection. Also, the four lintel beams are too wide for the post in use and the post was not intended to be used for four beams or an 8" lintel. The post appears to be designed to accomodate two beams or a 4" lintel, as shown by the post being installed sideways to allow all four beams to rest upon it. Recommend evaluation and any necessary mitigation by a licensed structural contractor."
How did I do? Or, is the install correct and i called out for a structural contractor for nothing?
Thanks as always gentlemen and any potential ladies.