View Single Post
  #11 (permalink)  
Old 08-19-2008, 12:40 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,293
Re: A few good reasons new home buyers need us!
Quote:
Originally Posted by Scott Patterson View Post
In the second picture it shows a TJI joist that has had the top cord cut to accommodate the line for a toilet. Can't cut the top or bottom cord of a engineered joist.

This is a better picture:

Also needs to be firestopped around that pipe. And, no, more 'caulking' is not going to do it.

In fact, ... (oh, no, not this again) ... is that caulking even compatible (chemical compatibility-wise) with that PVC?

I know, the TJI cut top chord is more of a major issue, just checking to see if you got the secondary issues too.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com