PDA

View Full Version : Murder Inc. Backup Plan



Gary Burnett
02-17-2009, 11:25 AM
Makes me believe there is a real reason to protect people from themselves.
Flex connector in the wood burning firebox and just in case that doesn't kill you it's piped in in copper from under the house.
These things keep the job interesting.

A.D. Miller
02-17-2009, 11:35 AM
Makes me believe there is a real reason to protect people from themselves.
Flex connector in the wood burning firebox and just in case that doesn't kill you it's piped in in copper from under the house.
These things keep the job interesting.

Gary: As in redundant roasting?

Bob Harper
02-18-2009, 06:29 AM
They're using a sand pan type vented gas log burner as a log lighter. Also, log lighters must be piped with black iron--no flex, esp. flex connectors or copper.

Good catch.

John Arnold
02-18-2009, 06:33 AM
Hi Bob -

Re your signature, I thought we were supposed to keep the fire IN the fireplace?

Donald Merritt
02-19-2009, 10:10 PM
Boom !!! :p

Don Merritt
Germantown, Tennessee

Timothy M. Barr
02-20-2009, 07:57 AM
Was it natural gas or propane.. I see a lot of propane companies run copper feed lines then tie into black iron at the furance

Gary Burnett
02-20-2009, 10:01 AM
It was natural gas.

Mark Jones
02-20-2009, 11:11 AM
I love your title, Gary!
:D

Michael Thomas
02-20-2009, 07:00 PM
Bob,

Great to see you back!

Michael Thomas
02-20-2009, 07:02 PM
Anyone else remember the opening scene from "The Mechanic"?