View Full Version : Heat Pump Identification
Frank Bombardiere
01-28-2013, 05:38 PM
Is a Model CKL36-1H Goodman condensing unit a heat pump? Could not see inside to see reversing valve.
I believe the second letter would be a P if it was a heat pump but I am not sure.
Vern Heiler
01-28-2013, 06:01 PM
Is a Model CKL36-1H Goodman condensing unit a heat pump? Could not see inside to see reversing valve.
I believe the second letter would be a P if it was a heat pump but I am not sure.
Trying to make sense of manufacturers model number schemes is the rock you will perish on. Google Goodman CKl36-1 and you should find that it is a condenser unit not heatpump.
Nick Ostrowski
01-28-2013, 06:12 PM
Is a Model CKL36-1H Goodman condensing unit a heat pump? Could not see inside to see reversing valve.
I believe the second letter would be a P if it was a heat pump but I am not sure.
Any pics of the unit label?
Frank Bombardiere
01-28-2013, 06:25 PM
Here is a pic. I think it is not a heat pump.
Nick Ostrowski
01-29-2013, 05:05 AM
How about the thermostat inside the house? Was it a heat pump thermostat with an emergency backup heat mode option?
Dom D'Agostino
01-29-2013, 06:09 AM
I Could not see inside to see reversing valve.
Curious, why is that?
Jeff Zehnder
01-29-2013, 06:42 AM
Reversing valve and accumulator pretty much means it is a heat pump!
Rory Hernandez
02-10-2013, 06:12 PM
I train my inspectors, that no matter what the label "implies" ALWAYS verify the condenser is running when you have the thermostat in "heat" mode as sometimes things can change. Just because you are getting heat, doesn't mean the heat pump (if one) is running properly.
Vern Heiler
02-10-2013, 10:06 PM
I train my inspectors, that no matter what the label "implies" ALWAYS verify the condenser is running when you have the thermostat in "heat" mode as sometimes things can change. Just because you are getting heat, doesn't mean the heat pump (if one) is running properly.
And just because it is not running does not mean there is anything wrong. There are multi-fuel heating systems, like mine!
Ray Thornburg
02-11-2013, 08:22 AM
Is a Model CKL36-1H Goodman condensing unit a heat pump? Could not see inside to see reversing valve.
I believe the second letter would be a P if it was a heat pump but I am not sure.
Here is a page I wrote to address this issue. Hope it helps someone. How do I know if I have a heat pump? | Blue Palmetto Home Inspection (http://www.summerville-home-inspector.com/content/how-do-i-know-if-i-have-heat-pump)