PDA

View Full Version : YORK HVAC Age



ROBERT YOUNG
03-04-2017, 08:00 AM
Need help determining YORK HVAC production year.
CSA label is not legible.
3337633377

Much thanks as always.

PS: Ray back yet?

Jerry Peck
03-04-2017, 10:08 AM
Does 01/91 sound likely?

If Raymond is not back yet by Brian - that is not a good sign for this board ... and if Raymond is not back BY HIS OWN CHOICE ... then that is an even worse sign for this board.

Gary Burnett
03-04-2017, 02:42 PM
Jerry nailed it!

ROBERT YOUNG
03-04-2017, 04:33 PM
Does 01/91 sound likely?

If Raymond is not back yet by Brian - that is not a good sign for this board ... and if Raymond is not back BY HIS OWN CHOICE ... then that is an even worse sign for this board.

Thanks Jerry.
Canadian SEARS version.
MAYN101856 throws me right off.
The Building Intelligence Center under YORK year portion is a number not a letter of the alphabet. M(A?)YN101856

As for Ray.
A close friend said next week. Monday likely.
Be happy when he is back. Always good information from Ray.
If he does not post it maybe because he is preoccupied.

Much thanks!

Jerry Peck
03-04-2017, 04:34 PM
Jerry nailed it!

Look at the bottom right of the full label photo ... :D

ROBERT YOUNG
03-04-2017, 05:20 PM
Look at the bottom right of the full label photo ... :D
That is where you find the age on Canadian models?

I stared at that but did not want to guess.

You are the king and I am not worthy.:hail:

Jerry Peck
03-04-2017, 05:35 PM
That is where you find the age on Canadian models?

I stared at that but did not want to guess.

You are the king and I am not worthy.:hail:

I guessed that "MFD" stood for "manufactured", then there was what looked like a 'date of manufacture' after it.

Garry Sorrells
03-05-2017, 08:46 AM
Building Center
manufacture or age of an YORK® furnace or other manufactured YORK® HVAC unit | Building Intelligence Center (http://www.buildingcenter.org/york)

or

How To Read York Hvac Model And Serial Number; by Dadan - York Hvac Serial and Model Number How To Read York Hvac Model And Serial Number (http://www.central-air-conditioner-and-refrigeration.com/how-to-read-york-hvac-model-and-serial-number.html)
York hvac had two different serial numbers for 1971 through 2004 and 2005 through the present day.

Old Serial Number from 1971 – October, 2004

Old Serial Number format look like this: XBFM220710, EADM203490, and BKJM310394.

New Serial Number from October, 2004 to the present day

New serial number format looks like this. W0E4298223, N0D6941103, and A0E5219381. York Hvac New Serial Number (http://www.central-air-conditioner-and-refrigeration.com/how-to-read-york-hvac-model-and-serial-number.html#NewSerialNumber)


Click the link in the bottom of the pages for question

Here how to read the old serial number: X B F M 220710

1st digits X is the plant. X was made in Mexican


A = Addison
B = Blackville
C = Canada
D = Medina
E = Elyria
M = Mad’ville
N = Norman
W = Wichita
X = Mexico
Y = York

2nd digits B are the month. B is in February


A = January
B = February
C = March
D = April
E = May
F = June
G = July
H = August
“I” was skipped
“J” was skipped
K = September
L = October
M = November
N = December

3rd digits F are the year. F is in 1976 or 1997


A = 1971 or 1992
B = 1972 or 1993
C = 1973 or 1994
D = 1974 or 1995
E = 1975 or 1996
F = 1976 or 1997
G = 1977 or 1998
H = 1978 or 1999
“I” was skipped
J = 1979 or 2000
K = 1980 or 2001
L = 1981 or 2002
M = 1982 or 2003
N = 1983 or 2004
(The month October, November, and December does not count with 2004)
“O” was skipped
P = 1984
“Q” was skipped
R = 1985
S = 1986
T = 1987
“U” was skipped
V = 1988
W = 1989
X = 1990
Y = 1991