is it a requirement for the corner joints to be soldered and/or sealed?
Jim Robinson
09-03-2020, 12:10 PM
Not that I am aware of. Certainly good practice to seal them but I don't think I have ever seen a field built flashing soldered. The sealant would tend to be under the metal so mostly would not be visible.
Markus Keller
09-04-2020, 08:10 AM
That open corner should be clipped in under the other piece so that it keeps the corner closed. That's why it has that U hook type end.
Never seen anybody solder the corners. That flashing is mostly about water run off not so much sealing. The sealing is done by the stuff underneath.