InspectionNews - Home Inspection


Share |

Welcome to InspectionNews.

Registration is FREE!

Why join InspectionNews? Read the Testimonials

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but you will not see any of the pictures or technical bulletins that have been uploaded.

There are over 11,850 inspectors who have already joined InspectionNews, contributing over 100,700 posts. By joining InspectionNews you will be able to see the pictures, start new threads, reply to posts, communicate privately with other members, respond to polls, upload content and access many other special features.

If you are an inspector or thinking about becoming one, InspectionNews is the place for you.

Registration is FREE because the sponsors pay your way.
Please visit all the sponsors often and let them know that you found them on InspectionNews!

How much should an inspection cost? Click the banner below to find out.
The Cost Of Business

If you have any problems with the registration process or your account login, please contact us.

Registration is easy, so please Join InspectionNews Today!

United Infrared Inc
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-30-2010, 01:49 PM
Greg Jenkins Greg Jenkins is offline
Member
 
Join Date: Mar 2007
Location: Charleston, WV
Posts: 67
Rafter Splice/Engineers comments
Inspected this attic of a modular home several months ago. I had limited access to the attic but called out the rafter splices as questionable.
Engineer comes back and says they are a "hinged roof truss framing system...and are common construction techniques in the modular home industy" and that all is ok.
The first pic is in an attic knee wall area. The other pics are of the attic.
I think the engineer looked in behind the knee walls and didn't actually enter the attic. (area above a third floor ceiling)
I am just looking for other opinions.
Attached Images
File Type: jpg DSCN3095.JPG (96.8 KB, 62 views)
File Type: jpg DSCN3091.JPG (93.7 KB, 75 views)
File Type: jpg DSCN3093.JPG (93.4 KB, 64 views)
File Type: jpg DSCN3090.JPG (93.3 KB, 64 views)
__________________
Greg Jenkins
Reply With Quote
United Infrared
  #2 (permalink)  
Old 07-30-2010, 07:10 PM
John Kogel's Avatar
John Kogel John Kogel is online now
Member
 
Join Date: Feb 2009
Location: Southern Vancouver Island
Posts: 1,213
Re: Rafter Splice/Engineers comments
Pics 2,3,and 4 show saw cuts in the rafters which have been sistered. If the scabbed-on peices are well nailed, I would be inclined to just describe them as spliced rafters. It would seem the engineer has taken on the responsibility for them.

Could they have been trying to straighten out a hump in the roofline in that area? That is what that looks like to me, some corrective surgery to improve the look of the roof after they raised it.
__________________
John Kogel, RHI, BC HI Lic #47455
www.allsafehome.ca
Reply With Quote
  #3 (permalink)  
Old 07-31-2010, 11:05 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 16,414
Re: Rafter Splice/Engineers comments
Quote:
Originally Posted by Greg Jenkins View Post
Engineer comes back and says they are a "hinged roof truss framing system...and are common construction techniques in the modular home industy" and that all is ok.

...

The first pic is in an attic knee wall area. The other pics are of the attic.
I think the engineer looked in behind the knee walls and didn't actually enter the attic. (area above a third floor ceiling)

Regarding the first part ... "and that all is ok" ... if that is what the engineer said, then you are 'off the hook' so to speak, however, like John said, but more than John said also, the rafters were saw cut ... TWO were saw cut ... and one was added, AND there looks to have been a diagonal web which was removed (based on what remains of the truss plate).

I agree with your take in that the engineer probably only looked at the knee wall area, nonetheless, though, if the engineer said that all is ok - he bought that baby.

To me, if TWO trusses were cut, the TWO repairs would need to be made, one for each cut truss, and than those removed diagonal webs should have been specifically addressed by the engineer too ... but that is "to me and in my opinion".
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #4 (permalink)  
Old 07-31-2010, 04:34 PM
Greg Jenkins Greg Jenkins is offline
Member
 
Join Date: Mar 2007
Location: Charleston, WV
Posts: 67
Re: Rafter Splice/Engineers comments
Thanks for the feedback everyone. I probably should have posted this in the "inspection blues" category.
I was comfortable with calling out the framing as questionable. I got the blues when the engineers report came back, said the framing was sufficient and that my comments were the result of an "untrained eye." However, the engineers report has no mention of the altered framing. He only indicates that the house is modular construction with a hinged trusses. So I think HE thinks that I looked at the metal gussets (visible in the first Pic) and called that out as questionable.
Here's the Kicker. The engineer is a home inspector and he did the original inspection for the current home owner. Can you say CYA.
__________________
Greg Jenkins
Reply With Quote
  #5 (permalink)  
Old 07-31-2010, 04:45 PM
Jerry McCarthy's Avatar
Jerry McCarthy Jerry McCarthy is offline
Member
 
Join Date: Mar 2007
Location: Healdsburg, CA
Posts: 1,498
Re: Rafter Splice/Engineers comments
Greg
For what its worth, you're right and EC Jerry P is right (no surprise there), and it appears the PE goofed, but as we all know he has bought the problem and it now belongs to him. Don't you love it when folks with letters after their name come along and lift the monkey off your back and put it on their own?
__________________
Jerry McCarthy
Building Code/ Construction Consultant
http://www.homeinspectorlitigation.com/
Reply With Quote
  #6 (permalink)  
Old 08-01-2010, 08:21 AM
Eric Barker's Avatar
Eric Barker Eric Barker is offline
Member
 
Join Date: Mar 2007
Location: Barrington, IL
Posts: 606
Re: Rafter Splice/Engineers comments
It's frustrating when you bust butt to find concerns then have someone who is supposedly more qualified than you give a condition the thumbs up. What really bothers me is that the person has not done his job and in some cases has tarnished my image since people will think I was wrong and he was right.
__________________
Eric Barker
Moraine Woods Consulting, Inc.
Barrington, IL
Reply With Quote
FREA Home Inspector Insurance
United Infrared Inc
Reply

Share |

Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
50% of engineers graduated in the bottom half of their class Vern Heiler Attic Areas: Home Inspection and Commercial Inspection 20 02-09-2010 06:22 PM
Rafter Splice - Staples RobertSmith Attic Areas: Home Inspection and Commercial Inspection 10 08-05-2009 04:06 AM
AHJs, Engineers, and Structural Modifications Michael Thomas Structural Components: Home Inspection and Commercial Inspection 1 02-04-2009 10:19 AM
Women as explained by engineers Jerry Peck General Chit Chat: Home Inspectors & Commercial Inspectors 5 11-01-2007 03:27 PM
Ethics and engineers Jim Luttrall Associations, Ethics, Standards, Licensing, Legislation:Home Inspectors & Commercial Inspectors 8 06-18-2007 04:19 PM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 02:19 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger