InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 10-14-2007, 01:00 PM
Zibby Swieca Zibby Swieca is offline
Member
 
Join Date: Sep 2007
Location: San Antonio TX
Posts: 81
Attic issues
Could I get some comments?
Thanks
Attached Images
File Type: jpg zdjecia 8-23 114.jpg (78.1 KB, 162 views)
File Type: jpg zdjecia 8-23 121.jpg (66.4 KB, 148 views)

Last edited by Zibby Swieca : 10-14-2007 at 01:08 PM.
Reply With Quote
United Infrared
  #2 (permalink)  
Old 10-14-2007, 01:17 PM
Paul Kondzich Paul Kondzich is offline
Member
 
Join Date: Mar 2007
Location: Woodland Park, CO.
Posts: 188
Re: Attic issues
In the first picture: all the yellow wires on the rear wall, are they coming from some type of outlet???
__________________
Paul Kondzich
Altitude Home Inspection INC.
Woodland Park, CO.
Reply With Quote
  #3 (permalink)  
Old 10-14-2007, 01:52 PM
Zibby Swieca Zibby Swieca is offline
Member
 
Join Date: Sep 2007
Location: San Antonio TX
Posts: 81
Re: Attic issues
They are water supply pipes.
Reply With Quote
  #4 (permalink)  
Old 10-14-2007, 02:01 PM
Paul Kondzich Paul Kondzich is offline
Member
 
Join Date: Mar 2007
Location: Woodland Park, CO.
Posts: 188
Re: Attic issues
Oh ok...
__________________
Paul Kondzich
Altitude Home Inspection INC.
Woodland Park, CO.
Reply With Quote
  #5 (permalink)  
Old 10-14-2007, 03:45 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is online now
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,797
Re: Attic issues
Uhh, the yellow lines are CSST gas lines, they are coming off a manifold. The Red and Blue are PEX water lines.

What information are you looking for?
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #6 (permalink)  
Old 10-14-2007, 04:46 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: Attic issues
Zibby,

In Picture 1 it looks like bathroom vent does not go through the roof.

It may dead end or Vent through a Soffit Vent neither is allowed.

The Gas and water service lines I'll leave to someone else.

Picture 2 The purlin,wed member,brace under the rafter is misaligned you can see the pencil marks where it should have been.
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.

Last edited by Billy Stephens : 10-14-2007 at 04:53 PM. Reason: Brace under rafter
Reply With Quote
  #7 (permalink)  
Old 10-14-2007, 05:55 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: Attic issues
As Scott asked "What information are you looking for?"

The yellow CSST gas lines are not properly supported.

That white plastic duct is not allowed for any use, much less in the attic.

The ceiling joists (based on the direction of the insulation and the boards laying on the insulation) are running perpendicular to the rafters, indicating that rafters ties will be required (but none are shown in the photo).

The PVC vent at the gable end needs to be strapped and supported.

The second photo shows a rafter only partially bearing on a 2x laid flat-wise (I am guessing that this was done to get more bearing than just the top of that 2x the flat-wise one is on). Is this at a valley?
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #8 (permalink)  
Old 10-14-2007, 06:10 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: Attic issues
Quote:
Originally Posted by Jerry Peck View Post
That white plastic duct is not allowed for any use, much less in the attic.
Your a hard man Mr. Peck.
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Reply With Quote
  #9 (permalink)  
Old 10-14-2007, 06:36 PM
Zibby Swieca Zibby Swieca is offline
Member
 
Join Date: Sep 2007
Location: San Antonio TX
Posts: 81
Re: Attic issues
Any info is a great help.
Tis is new home and there are so many items incorrectly done, for example flashing.

Thank You
Attached Images
File Type: jpg zdjecia 8-23 075.jpg (63.8 KB, 109 views)
File Type: jpg zdjecia 8-23 099.jpg (65.6 KB, 111 views)
File Type: jpg zdjecia 8-23 109.jpg (61.6 KB, 113 views)
File Type: jpg zdjecia 8-23 115.jpg (63.1 KB, 109 views)
Reply With Quote
  #10 (permalink)  
Old 10-14-2007, 06:52 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: Attic issues
Zibby,

The Gas appliance flue has Aluminum Tape instead of screws and over time will fall off.
They should be joined with 3 screws.

The bundle or bunch of improperly installed wires in contact with flue is a fire hazard.

Shoot the Builder.

Stay Tuned For Much More!
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Reply With Quote
  #11 (permalink)  
Old 10-14-2007, 08:30 PM
Richard Moore's Avatar
Richard Moore Richard Moore is offline
Member
 
Join Date: Mar 2007
Location: Seattle, WA
Posts: 349
Re: Attic issues
"Shoot the Builder."

Making the builder live in the home would be a more apt punishment!

Were the plans in crayon? If what is visible is so screwed up, do you think the covered up stuff is any better?

Report..."Builder hasn't a clue. Find another house!"
__________________
Richard Moore
Rest Assured Inspection Services - www.rainspect.com
Seattle, Washington
Reply With Quote
  #12 (permalink)  
Old 10-14-2007, 09:02 PM
Jim Luttrall Jim Luttrall is offline
Member
 
Join Date: Mar 2007
Location: Allen, Texas
Posts: 2,497
Re: Attic issues
Richard Moore, good report. This house has more problems than you can count just in the attic. RUN!
Find another house.
__________________
Jim Luttrall
www.MrInspector.net
Allen, Texas 75002
Reply With Quote
  #13 (permalink)  
Old 10-14-2007, 09:20 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: Attic issues
Zibby,

I thought the flue Pipe in the 3rd picture was on the wall.

On blowup second look it's on top of the ceiling and runs FLAT!

There is noway it's going to vent the gas exhaust and could KILL the occupants!!!!

Call the locale AHJ NOW!!!
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Reply With Quote
  #14 (permalink)  
Old 10-14-2007, 09:24 PM
Zibby Swieca Zibby Swieca is offline
Member
 
Join Date: Sep 2007
Location: San Antonio TX
Posts: 81
Re: Attic issues
Wish me luck with the report.
Its 20 minutes after 10 PM and it has to by done by tomorrow morning and Im not even half way through.
Thanks for your responses.
Zibby
Reply With Quote
HomeGauge Reports
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Attic insulation Rick Cantrell Attic Areas: Home Inspection and Commercial Inspection 11 01-19-2008 07:34 AM
Inspector should have noticed chimney issues - Contra Costa Times Brian Hannigan Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 10 10-07-2007 06:17 PM
Attic Inspection Lynn Petrie Attic Areas: Home Inspection and Commercial Inspection 36 09-26-2007 12:36 PM
Attic painted Jim Kasterko Attic Areas: Home Inspection and Commercial Inspection 3 07-10-2007 06:58 AM
Maine issues child-care swim standards after Westbrook drowning - Foster's Daily Demo Brian Hannigan Pool and Spa: Home Inspection and Commercial Inspection 0 05-18-2007 11:50 AM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 08:00 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger