You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 01-30-2008, 09:48 AM
Zibby Swieca Zibby Swieca is offline
Member
 
Join Date: Sep 2007
Location: San Antonio TX
Posts: 72
How do I write this up?
How do I write this up?
Attached Images
File Type: jpg 3366 Tavern Oaks 030.jpg (46.8 KB, 122 views)
Reply With Quote
  #2 (permalink)  
Old 01-30-2008, 10:10 AM
Nolan Kienitz's Avatar
Nolan Kienitz Nolan Kienitz is offline
Member
 
Join Date: Mar 2007
Location: Dallas Home Inspections
Posts: 344
Re: How do I write this up?
Remove tapped drain. Not an approved connection.

Also appears to be incorrect sealing at PVC joints
__________________
Cheers - Nolan E. Kienitz, HCRI, PMP
ICC Certified Residential Plumbing Inspector (P-1)
www.NolansInspections.com
Reply With Quote
  #3 (permalink)  
Old 01-30-2008, 10:14 AM
Richard Rushing's Avatar
Richard Rushing Richard Rushing is offline
Member
 
Join Date: Mar 2007
Location: Duncanville, Tx
Posts: 1,086
Re: How do I write this up?
IRC code [1411.3] states that condensate
should have no direct connection to waste or vent pipe.
__________________
"If con is the opposite of pro, is Congress the opposite of progress?"
Richard Rushing, HCRI
Duncanville, Tx.
Reply With Quote
  #4 (permalink)  
Old 01-30-2008, 10:24 AM
John Arnold John Arnold is online now
Member
 
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,338
Re: How do I write this up?
Quote:
Originally Posted by Zibby Swieca View Post
How do I write this up?
"Insufficient silicone caulk."

I kid, as Bill Maher says.
Reply With Quote
  #5 (permalink)  
Old 01-30-2008, 02:13 PM
Inspector bob Inspector bob is offline
Member
 
Join Date: Jan 2008
Location: chandler
Posts: 1
Re: How do I write this up?
Quote:
Originally Posted by Richard Rushing View Post
IRC code [1411.3] states that condensate
should have no direct connection to waste or vent pipe.
What version of the IRC are you reading? I can't seem to find a single edition where it states what you quoted? ........

Ever seen a condensation line hooked into the tailpiece of the lav??? It is done all the time and is legal.
Is this an interpretation of that code section in your state????
Just wondering if everyone here in Az. is doing their jobs incorrectly.
Reply With Quote
  #6 (permalink)  
Old 01-30-2008, 02:35 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,790
Re: How do I write this up?
Inspector bob,

First, welcome to THE home inspectors board.

Secondly, we all use our real names here, so, if you would, please click on the 'Contact Us' link at the bottom of the page and Brian will reset your user name to your real name.

Quote:
Originally Posted by Inspector bob View Post
Ever seen a condensation line hooked into the tailpiece of the lav???
Unfortunately, yeah.

Quote:
It is done all the time and is legal.
You are so wrong there. Your first post here and you are trying to tell us that something not allowed by code is allowed, and doing so after questioning someone else about code back?

Please provide your code backup.

Here is mine.

A/C condensate is an indirect waste, and as such, is required to be connected through an indirect waste fitting, an air gap.

From the 2006 IRC. (underlining is mine)
- P2706.3 Prohibited waste receptors.
Plumbing fixtures that are used for domestic or culinary purposes shall not be used to receive the discharge of indirect waste piping.

- - Exceptions:
- - - 1. A kitchen sink trap is acceptable for use as a receptor for a dishwasher.
- - - 2. A laundry tray is acceptable for use as a receptor for a clothes washing machine.

You will, quite hopefully, have already noticed that: a) exception 1. is for kitchen sinks and ONLY allows indirect waste from a dishwasher; b) exception 2. is for a laundry tray (i.e, a laundry sink) and ONLY allows indirect waste from a clothes washer; c) that there is no 3. for anything else, not even a vanity.

My apologies for the tone of the above response, but your first post carries the same tone toward the other poster, as shown below.

Quote:
Is this an interpretation of that code section in your state????
Just wondering if everyone here in Az. is doing their jobs incorrectly.
*I* am wondering if *YOU* are doing *YOUR* job correctly ... by the way, your job is not (hopefully) as a plumbing code inspector, is it?

Hopefully, you will contact Brian and have him change your username, then continue to post here as we can all learn from each other, as long as we do it "nicely", otherwise, bad attitudes can be treated with equal responses.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
How would you write this up Zibby Swieca Electrical Systems: Home Inspection and Commercial Inspection 12 12-10-2007 12:25 PM
How to write up dan orourke Plumbing System: Home Inspection and Commercial Inspection 26 11-20-2007 09:44 AM
How to write up Clay White Roofing System: Home Inspection and Commercial Inspection 15 10-25-2007 07:39 PM
How to write this up Jeff Eastman Electrical Systems: Home Inspection and Commercial Inspection 1 07-09-2007 10:46 PM
How would you write this up wayne soper Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 5 04-05-2007 07:28 PM


All times are GMT -7. The time now is 05:51 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger