You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 04-07-2008, 07:46 PM
David Block David Block is offline
Member
 
Join Date: Mar 2007
Location: Lenexa, Ks
Posts: 35
What were they thinking?
I was inspecting this 40 year old house that had just recently been rehabbed by an investor. The roof was a couple months old. While on the roof, I didn't see a vent pipe for the furnace and no vent pipes were visible through the exterior walls...I assumed an electric furnace/heat pump system. I found a mid-efficiency gas furnace in the basement and knew right away I was about to find something interesting. In the attic space I found the vent pipe terminating in the attic space. There was a roof vent placed over top of the vent pipe. I know roofers are not HVAC guys but could you really be that dense to think that this setup is alright. Luckily the home has been unoccupied with the utilities shutoff. Who knows how long it would have taken before the roof sheathing caught fire. I love inspecting rehabbed houses...I always find the most unique things.
Attached Images
File Type: jpg Picture 106.jpg (45.3 KB, 171 views)
Reply With Quote
  #2 (permalink)  
Old 04-08-2008, 06:10 AM
Markus Keller Markus Keller is offline
Member
 
Join Date: Feb 2008
Location: Chicago IL
Posts: 373
Re: What were they thinking?
I had one like that one time. The owner actually told the roofers to leave the vent in the attic.
- He didn't like the look of the metal pipe and cap coming out of this new arch. shingle roof.
- And besides, it's a raw attic, 'Can't you feel all the breeze in here'? 'The fumes will just get blown out'. 'We don't use the furnace that much anyway'.

I swear it's true. I wish I was making it up. Maybe I should have kept my mouth shut. Him not having kids might have been better for society in the long run.
__________________
Accurate Inspections & Consulting, Inc.
847/736-9975
Markus Keller
Reply With Quote
  #3 (permalink)  
Old 04-08-2008, 08:08 AM
Jim Luttrall Jim Luttrall is offline
Member
 
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,392
Re: What were they thinking?
David, I think you are relying on facts not in evidence.

What were they thinking? Answer, they weren't.

Nobody can possibly be that ignorant... can they?
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
Reply With Quote
  #4 (permalink)  
Old 04-08-2008, 08:26 AM
Aaron Miller Aaron Miller is offline
Senior Member
 
Join Date: Mar 2007
Location: Nowhere, USA
Posts: 828
Re: What were they thinking?
Quote:
What were they thinking? Answer, they weren't.
Let's be fair now. Thinking is not always an option for tradesmen . . . It's not their fault, they just don't have any capacity . . .
Reply With Quote
  #5 (permalink)  
Old 04-08-2008, 08:42 AM
Markus Keller Markus Keller is offline
Member
 
Join Date: Feb 2008
Location: Chicago IL
Posts: 373
Re: What were they thinking?
Jim, that's a very good point. The homeowner in my post, also 'thought' it was OK, because they ran the flue over to the roof vent. I think it was about a foot below the vent.
Other than that, let's not blame it all on the tradesmen, how about just the roofers or the HGTV do it yourselfers?
Have fun.
__________________
Accurate Inspections & Consulting, Inc.
847/736-9975
Markus Keller
Reply With Quote
  #6 (permalink)  
Old 04-09-2008, 04:07 AM
Darren Miller's Avatar
Darren Miller Darren Miller is offline
Member
 
Join Date: Mar 2007
Location: Succasunna NJ
Posts: 133
Re: What were they thinking?
David;

It also looks like a single wall vent.

Double wall is needed when passing thru an unconditioned space.
__________________
Darren
Succasunna, NJ
www.aboutthehouseinspections.com
Reply With Quote
  #7 (permalink)  
Old 04-09-2008, 06:31 AM
Bob White's Avatar
Bob White Bob White is offline
Member
 
Join Date: Mar 2007
Location: Cartersville, GA
Posts: 69
Re: What were they thinking?
Quote:
Originally Posted by Darren Miller View Post
David;

It also looks like a single wall vent.

Double wall is needed when passing thru an unconditioned space.

But it's not passing through, is it?
__________________
Bob White

www.abide-able.com
Reply With Quote
  #8 (permalink)  
Old 04-09-2008, 04:32 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,395
Re: What were they thinking?
Quote:
Originally Posted by Bob White View Post
But it's not passing through, is it?
Now you are beginning to sound like Jerry, using technicalities in wording and all.

Crimeny, what's next?
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #9 (permalink)  
Old 04-10-2008, 12:17 PM
Robert Koch Robert Koch is offline
Member
 
Join Date: Mar 2007
Location: Mars, PA
Posts: 14
Re: What were they thinking?
Passing through the floor/ceiling assembly.
Reply With Quote
  #10 (permalink)  
Old 06-09-2008, 12:06 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,053
Re: What were they thinking?
I thought THIS was sorta' special: a little "ramp" catching some sort of leakage or condensation from the far side of the air handler (there is no drain for the pan, but there is a float switch at the far end of the pan, not visible in this picture),.

I presume they must have installed that elbow and vertical tube because they did not have a plug.

anyway, mu question is: can you even drain the A-coil's pan from below like that?... I've always see it done on the side on a horizontal air handler.
Attached Images
File Type: jpg a080609-1-pan.jpg (103.8 KB, 61 views)
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com

Last edited by Michael Thomas : 06-09-2008 at 01:47 PM.
Reply With Quote
  #11 (permalink)  
Old 06-10-2008, 03:37 PM
CHARLIE VAN FLEET's Avatar
CHARLIE VAN FLEET CHARLIE VAN FLEET is offline
Member
 
Join Date: Apr 2007
Location: WESTMINSTER CO
Posts: 138
Re: What were they thinking?
call the city premit department and see if a permit was pulled and if it was--did the city inspect the completion on this---highly think not
charlie
Reply With Quote
  #12 (permalink)  
Old 06-10-2008, 05:40 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,395
Re: What were they thinking?
Charlie,

It may have been a permitted job, and that ramp added later.

Regarding Michael's "I presume they must have installed that elbow and vertical tube because they did not have a plug." ... the city likely 'required' that "vent" for the auxiliary drain pan ... not that it needs one, but, I've actually seen municipal inspectors require the same thing.
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #13 (permalink)  
Old 06-10-2008, 05:45 PM
imported_John Smith imported_John Smith is offline
Member
 
Join Date: Mar 2007
Location: Alvin Texas
Posts: 348
Re: What were they thinking?
I dont know, is the "ramp" a big deal? Remember in the old days, they used to use chains for downspouts.

Interesting though
Reply With Quote
  #14 (permalink)  
Old 06-10-2008, 06:33 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,053
Re: What were they thinking?
Quote:
Originally Posted by Jerry Peck View Post
the city likely 'required' that "vent" for the auxiliary drain pan ... not that it needs one, but, I've actually seen municipal inspectors require the same thing.
In that case, they are clinically insane.

------------

To get back to my question,

1) Are there A-Coils intended to drain through the bottom like that in horizontal installations... I've never seen one with a condensate drain on the bottom before, only on the sides.

2) If so, how should the trap be laid out?
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
  #15 (permalink)  
Old 06-13-2008, 07:02 AM
Don Norman Don Norman is offline
Member
 
Join Date: Mar 2007
Posts: 3
Re: What were they thinking?
Good morning Michael,

In answer to your first question, yes, a drain pan can be drained through the bottom if designed to do that by the manufacturer but, like you, I've never seen the application.

Regarding the second question about trapping the condensate line if there is no diagram on the evaporator cabinet illustrating the trap layout you'll need to refer to the manufacturer's installation instructions.

One of the great things about the internet is that many manufacturers now put their installation manuals on the net. I've used it many times to determine what was supposed to be done.

Good luck,

Don Norman
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Just thinking Thom Walker Associations, Ethics, Standards, Licensing, Legislation:Home Inspectors & Commercial Inspectors 4 06-20-2007 11:12 AM
Thinking too hard? Jeff Eastman Building Envelope: Home Inspection and Commercial Inspection 8 06-02-2007 07:02 PM


All times are GMT -7. The time now is 12:33 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger