You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 08-26-2008, 06:08 PM
Stephen G Sheldon Stephen G Sheldon is offline
Member
 
Join Date: Jun 2008
Location: Atlanta
Posts: 11
Main Electric Panel in Closet
How would you report this condition (major repair/safety issue) or is it even necessary? The workmanship looks good but I realize the location is not ideal.
Reply With Quote
  #2 (permalink)  
Old 08-26-2008, 06:17 PM
Vern Heiler's Avatar
Vern Heiler Vern Heiler is offline
Member
 
Join Date: Mar 2008
Location: Charlotte NC
Posts: 168
Re: Main Electric Panel in Closet
Quote:
How would you report this condition
The panel in question "is missing".
Reply With Quote
  #3 (permalink)  
Old 08-26-2008, 06:22 PM
Stephen G Sheldon Stephen G Sheldon is offline
Member
 
Join Date: Jun 2008
Location: Atlanta
Posts: 11
Re: Main Electric Panel in Closet
Cute, Vern but whats that mean?
Reply With Quote
  #4 (permalink)  
Old 08-26-2008, 06:30 PM
Ted Menelly Ted Menelly is offline
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 1,303
Re: Main Electric Panel in Closet
Quote:
Originally Posted by Stephen G Sheldon View Post
Cute, Vern but whats that mean?
You did not add a pic. You stated the question like you were going to show the panel.

Many well, thusands, who knows how many electric panels in older homes were in the closet. They never should have been there.

You have to tell your folks that it may have once been allowed but is and has not been allowed
for safety reason for, well ever.(might as well be forever.

Even if you tell them of this you have to think of the clearance to the sides and the working clearance to the front. This is one of the big working on safety issues. Hanging clothes around it is a safety issue. If they are like half of them I find near where I live the panel itself FPE and such is a write up in itself. The suggestion to the client at the minimum would be to open that end of the closet so it is no longer in there or move it from the closet. It depends on the situation in the home you are inspecting.

The picture would give you a lot more for folks to write about.

Your question is it a big deal

YES
__________________
Ted Menelly
"Castle"
Home Inspection Services

Last edited by Ted Menelly : 08-26-2008 at 06:36 PM.
Reply With Quote
  #5 (permalink)  
Old 08-26-2008, 06:49 PM
Stephen G Sheldon Stephen G Sheldon is offline
Member
 
Join Date: Jun 2008
Location: Atlanta
Posts: 11
Re: Main Electric Panel in Closet
Ted,

Thanks for your response. I don't have a picture but I got the basics of what you are saying.
Reply With Quote
  #6 (permalink)  
Old 08-26-2008, 08:05 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,790
Re: Main Electric Panel in Closet
Quote:
Originally Posted by Stephen G Sheldon View Post
Cute, Vern but whats that mean?
What Vern meant was that you posted a post with no question or information in it.

Then, after having to look around at what you meant, the light came on - 'Oh, it is the heading to the thread.'

It is better for all if the thread identified what the question was about (yours did), then the post contained the actual question and information (yours lacked the question, so I am sure that Vern and I were not the only ones thrown off by what you were asking).

It is possible that Ted 'got it' immediately, good for Ted if he did.

I 'got it' after several seconds looking around for whateveritwas you were asking, then 'Oh, there it is in the heading.'
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Feed From Main Panel to Sub Panel Nick Ostrowski Electrical Systems: Home Inspection and Commercial Inspection 7 05-25-2008 06:38 PM
Water pipe above electric panel. Ken Amelin Electrical Systems: Home Inspection and Commercial Inspection 3 01-27-2008 11:08 AM
SE Panel In Close Closet OK K Robertson Electrical Systems: Home Inspection and Commercial Inspection 16 10-04-2007 01:28 PM
Electric water heater in bedroom closet? Trey Humphreys Plumbing System: Home Inspection and Commercial Inspection 0 06-07-2007 02:20 PM
General Electric Split Main Panel Joseph P. Hagarty Electrical Systems: Home Inspection and Commercial Inspection 1 05-23-2007 10:04 PM


All times are GMT -7. The time now is 06:07 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger