    It looks OK. As long as there are no gaps in it that would allow air into the house, then it is acceptable.

    ' correct a wise man and you gain a friend... correct a fool and he'll bloody your nose'.

  3. #3
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: Outrigger

    My main concern would be: How is that ledger secured to the wall structure?

    Nails? A no-no.

    Lag screws? Not the best idea either.

    Through bolts? Now you are talking.

    While you cannot see what was used from the outside any longer, if it was through bolted, you will see the trough bolts inside. If you see nothing, chances are it is only nailed up.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  4. #4
    Join Date
    Mar 2007
    Location
    Corpus Christi, TX
    Posts
    615

    Default Re: Outrigger

    Souldn't that top edge of the moisture barrier be beneath the thermo shield and not on top of it?