You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

06-08-2007, 10:55 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Minnesota
Posts: 4
|
|
|
garage quandry
Ok I'll admit I am kinda a newbie to this whole inspecting thing -- as such I need help from timt to time. Could one of you long time experts help me out with this one please.
Here is the description of the newer detatched garage. I will list the layers starting from the inside out.
2x4 stud -- felt paper -- vinyl siding
Am I missing something here?
|
|

06-08-2007, 11:59 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 678
|
|
|
Re: garage quandry
No sheathing?
No diagonal bracing?
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

06-09-2007, 12:59 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Duncanville, Tx
Posts: 1,086
|
|
|
Re: garage quandry
Where you are at, I would expect to see (a minimum) of 1/4 inch Fanfold board (polysteyerene insulation board).
Rich
__________________
"If con is the opposite of pro, is Congress the opposite of progress?"
Richard Rushing, HCRI
Duncanville, Tx.
|
|

06-09-2007, 05:16 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Indianapolis, Indiana
Posts: 344
|
|
|
Re: garage quandry
Erik,
Why do you need to know such information?
If it is visible and you mention it, it will be more informative for the client, If you can't see it, that doesn't always mean that it is absent. If you do mention it and can't see it and it is later dicscovered that it is not present when you said that it was, it soon will be and at your expense.
Like Richard said, there is usually be at least 1/4" fan board, which you should not see (except maybe under the starter strip, I don't look) because it is a fire hazard if left uncoveredand diagonal bracing or sheathing is needed to prevent racking and the eventual (probably pretty quick) collapse of the structure (sheathing may be visible from the inside). The lack of sheathing, or fanfold to provide a smooth surface for the siding will be apparent as will be the lack of sheathing or diagonal bracing for stability.
FYI. I usually pay more attention to the defficiencies.
__________________
Integrity Inspection Service, LLC
www.irsindy.com
(317) 345-1828
|
|

06-09-2007, 07:22 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,790
|
|
|
Re: garage quandry
Originally Posted by Jon Randolph
Erik,
Why do you need to know such information?
FYI. I usually pay more attention to the defficiencies.
I believe he is asking to see if there is a deficiency there.
I would suspect that the sheathing or lateral bracing would be visible from inside, then the felt (it's the barrier behind the vinyl siding), then the vinyl siding outside.
|
|

06-09-2007, 07:31 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Southborough, MA
Posts: 971
|
|
|
Re: garage quandry
My understanding is sheathing is not required as long as diagonal bracing in place. The Boston Globe years ago did a spotlight series on Toll Brothers and they were putting siding up with no sheathing.
__________________
Dave
|
|

06-09-2007, 07:40 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Land of Gar, TX
Posts: 394
|
|
|
Re: garage quandry
Originally Posted by Erik Elwood
Ok I'll admit I am kinda a newbie to this whole inspecting thing -- as such I need help from timt to time. Could one of you long time experts help me out with this one please.
Here is the description of the newer detatched garage. I will list the layers starting from the inside out.
2x4 stud -- felt paper -- vinyl siding
Am I missing something here?
Not sure if you question is structure or siding related.
Others addressed both but here is vinyl info:
http://www.vinylsiding.org/publicati...al_english.pdf
__________________
badair http://www.adairinspection.com Garland, TX 75042
Residential-Commercial-Construction-EIFS-Infrared Thermography
life is the random lottery of events followed by numerous narrow escapes
|
|

06-09-2007, 12:52 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Minnesota
Posts: 4
|
|
|
Re: garage quandry
sorry -- my post was kinda tounge-in-cheek I shoulda made that more clear
There was no sheathing (just those three items) and minimal bracing you could with no effort shake the garage quite a bit. I'll be honest, I do not know if it correct to code -- but it sure was not correct to common sense. Felt like a light wind would knock it over.
It was a rental duplex and the owner was a total slum lord, just the worst "repairs" I have ever seen -- felt sorry for the renters. This kind of inspection always makes me a bit tense, so much wrong I am always wondering if I caught it all
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
LinkBacks (?)
LinkBack to this Thread: http://www.inspectionnews.net/home_inspection/building-envelope-home-inspection-commercial-inspection/1559-garage-quandry.html
|
| Posted By |
For |
Type |
Date |
| a code height for the electric eyes? |
This thread |
Refback |
06-12-2007 09:40 AM |
All times are GMT -7. The time now is 06:00 AM.
| | |
|