InspectionNews - Home Inspection



Welcome to InspectionNews.

Registration is FREE!

Why join InspectionNews? Read the Testimonials

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but you will not see any of the pictures or technical bulletins that have been uploaded.

There are over 11,850 inspectors who have already joined InspectionNews, contributing over 100,700 posts. By joining InspectionNews you will be able to see the pictures, start new threads, reply to posts, communicate privately with other members, respond to polls, upload content and access many other special features.

If you are an inspector or thinking about becoming one, InspectionNews is the place for you.

Registration is FREE because the sponsors pay your way.
Please visit all the sponsors often and let them know that you found them on InspectionNews!

How much should an inspection cost? Click the banner below to find out.
The Cost Of Business

If you have any problems with the registration process or your account login, please contact us.

Registration is easy, so please Join InspectionNews Today!

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-02-2009, 01:31 PM
David Millner David Millner is offline
Member
 
Join Date: Mar 2007
Posts: 3
insulation in manufactured homes
Did a manufactured home for a client. Customer asked about insulation and found this tag info. I had to admit I could not provide an answer.


On the 'tag' of the modular was written: U sub 0, Walls 0.17

I have tried to find clarification can any of you shed light on this?

Thanks
Reply With Quote
HomeGauge Reports
  #2 (permalink)  
Old 07-02-2009, 02:20 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is offline
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,997
Re: insulation in manufactured homes
Quote:
Originally Posted by David Millner View Post
Did a manufactured home for a client. Customer asked about insulation and found this tag info. I had to admit I could not provide an answer.


On the 'tag' of the modular was written: U sub 0, Walls 0.17

I have tried to find clarification can any of you shed light on this?

Thanks
I have no idea. Keep in mind that manufactured homes are built to DOT guidelines.
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #3 (permalink)  
Old 07-02-2009, 06:49 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,976
Re: insulation in manufactured homes
Quote:
Originally Posted by David Millner View Post
On the 'tag' of the modular was written: U sub 0, Walls 0.17

The U factor is how the materials of the structure is constructed, with each material adding to the U factor.

The R-value is the reciprocal of the U factor, thus a U factor of "Walls 0.15" would equal an R value of "Walls R-5.88".

The "sub 0" may be the sub floor area?
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #4 (permalink)  
Old 07-02-2009, 06:59 PM
Dan Harris Dan Harris is offline
Member
 
Join Date: Mar 2007
Location: Mesa AZ
Posts: 527
Re: insulation in manufactured homes
Quote:
Originally Posted by David Millner View Post
Did a manufactured home for a client. Customer asked about insulation and found this tag info. I had to admit I could not provide an answer.


On the 'tag' of the modular was written: U sub 0, Walls 0.17

I have tried to find clarification can any of you shed light on this?

Thanks
If it's a Mfg. home , [ not a moduler] there should be a piece of paper with insulation information, wind zone and other info. taped or glued to the inside of a laundry room cabinet door , or a kitchen cabinet door.
__________________
Phoenix AZ Resale Home, Mobile Home, New Home Warranty Inspections. ASHI Certified Inspector #206929 Arizona Certified Inspector # 38440
www.inspectaz.com
Reply With Quote
  #5 (permalink)  
Old 07-03-2009, 07:07 AM
Ed Voytovich
 
Posts: n/a
Re: insulation in manufactured homes
Quote:
Originally Posted by Jerry Peck View Post
The U factor is how the materials of the structure is constructed, with each material adding to the U factor.

The R-value is the reciprocal of the U factor, thus a U factor of "Walls 0.15" would equal an R value of "Walls R-5.88".

The "sub 0" may be the sub floor area?
Jerry: The U-factors of materials cannot actually be added. Lower U-factors are better at stopping heat flow by conduction. Therefore, if you have a U=.02 material over a U=.05 material, adding them would appear to give you worse performance rather than better.

Pardon me if anybody's head explodes, but here's a definition: the U-factor tells us how many BTUs of heat pass through one square foot of a given material or assembly of materials per square foot of area per degree F difference in temperature. British Thermal Units are the way we quantify heat. A BTU=roughly the amount of energy contained in the head of a kitchen match; 100,000 BTUs equal one therm. Therms are how utility companies measure and charge for natural gas.

R-values represent resistance to heat flow. R-values can be added and then converted to U-factors by dividing them into 1. Since R-values get bigger as performance improves and U-factors get smaller, and since most Americans think that bigger is better, most window salespeople harp on R-values.

If you can find a window salesman who knows what a U-factor is, you might have a shot at a grown-up conversation about his product.

The U-factor can be found on the National Fenestration Rating Council (NFRC) sticker. Window R-values are as stated by the manufacturer, and are taken at the center of the glass. Just as home inspectors are third-party evaluators of real estate, the NFRC is a third party evaluator of windows. Talking about R-values is like taking the seller's word for the condition of the house.

There cannot be a U=0 value, so it's hard to interpret that part of the manufacturer's statement unless they rounded off. It can be very, very small, but it can't be zero because that would violate the Second and Third Laws of Thermodynamics. Heat absolutely, always, and inevitably goes from warm to cold. It might take it a very long time, but it will obey the Laws.

This is also why we cannot get to absolute zero temperature: there is nowhere for the last tiny bit of heat to go.

If you think State Highway Patrolmen are strict, The Laws of Thermodynamics make them look like a charitable organization. No slack. Absolutely no slack.

If you've read this far you may be thinking "All this stuff is beyond the scope, who's Ed trying to kid?" Everything here, except how to read an NFRC label, should be covered in middle school general science or earth science and again in elementary high school physics. It should be common knowledge. You can bet that students in India and China have no trouble understanding basic heat transfer. Let's keep up with them.
Reply With Quote
  #6 (permalink)  
Old 07-03-2009, 10:14 PM
John Kogel's Avatar
John Kogel John Kogel is offline
Member
 
Join Date: Feb 2009
Location: Southern Vancouver Island
Posts: 763
Re: insulation in manufactured homes
Quote:
Originally Posted by Jerry Peck View Post
The U factor is how the materials of the structure is constructed, with each material adding to the U factor.

The R-value is the reciprocal of the U factor, thus a U factor of "Walls 0.15" would equal an R value of "Walls R-5.88".
1 divided by 6 = 0.17. R6 won't sell trailers, so confuse them with 'U 0.17".
Quote:

The "sub 0" may be the sub floor area?
A while back, you said 'sub' was a submarine!
Reply With Quote
  #7 (permalink)  
Old 07-04-2009, 12:02 AM
Ron Bibler's Avatar
Ron Bibler Ron Bibler is offline
Member
 
Join Date: Mar 2008
Location: Healdsburg Ca
Posts: 2,148
Re: insulation in manufactured homes
I put an Infrared Camera on a few Mobile homes and its like nothing is there. with 2X2 walls you can't get much help. and i think if you were to get some help with insulation condensation would be a problem.

Best

Ron
Reply With Quote
  #8 (permalink)  
Old 07-04-2009, 07:41 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,976
Re: insulation in manufactured homes
Quote:
Originally Posted by John Kogel View Post
1 divided by 6 = 0.17. R6 won't sell trailers, so confuse them with 'U 0.17".
Yep, that's what I was pointing out.

Quote:
A while back, you said 'sub' was a submarine!
Right, under the sub floor is where they keep the submarine with the panel in it.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
Help Support InspectionNews
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
re; Inspection Manufactured homs daniel nantell General Chit Chat: Home Inspectors & Commercial Inspectors 2 04-22-2009 08:20 AM
manufactured homes Stephen Houmard Exterior Systems: Home Inspection and Commercial Inspection 5 09-28-2008 09:17 AM
Manufactured Turds Aaron Miller Plumbing System: Home Inspection and Commercial Inspection 3 04-14-2008 07:54 PM
Earth contact homes - exposed foundation wall insulation above grade Shane Pouch Building Envelope: Home Inspection and Commercial Inspection 4 12-07-2007 07:27 AM
Air Admitance Valve in Manufactured Home Terre G Plumbing System: Home Inspection and Commercial Inspection 12 04-11-2007 07:51 AM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 01:37 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger