You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 06-07-2007, 06:32 PM
Mike Huppi Mike Huppi is offline
Member
 
Join Date: Mar 2007
Location: Aloha Oregon
Posts: 125
Basement egress
I am trying to determine if a room has egress in a basement and am having a brain lapse.

The room has a door to a family room and a door to a bathroom which goes to the laundry room which goes back to the family room.

The window is 50" from the floor and the window is 21" wide and 32" high.

So does this room have to have the window the correct size for egress. My books say escape to the exterior, but is that the exterior of the room or the exterior of the home.

Mike

I think it should have a larger window to exit the home. The home is listed as it being a bedroom. It does have heat, power and a closet.
Reply With Quote
Are inspection referrals from past clients important to you? If so, click here to get even more referrals!
  #2 (permalink)  
Old 06-07-2007, 07:12 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,547
Re: Basement egress
Quote:
Originally Posted by Mike Huppi View Post
The window is 50" from the floor and the window is 21" wide and 32" high.

The home is listed as it being a bedroom. It does have heat, power and a closet.
The maximum allowable height for the window sill (not the 'sill', but the 'bottom of the opening') is 44" above the floor.

The minimum opening size is 5.0 sq ft, and 21" by 32" = 672 sq in / 144 = 4.67 sq ft.

The window is both too high and too small.

What about a window well outside (it's a basement)?

What about natural ventilation (4% of the area of the room) and natural light (8% of the area of the room)?
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #3 (permalink)  
Old 06-07-2007, 09:07 PM
Mike Huppi Mike Huppi is offline
Member
 
Join Date: Mar 2007
Location: Aloha Oregon
Posts: 125
Re: Basement egress
There is no well it goes onto the ground that is why I said it was 50" off the floor or ground sorry, so there is no well. The base of the window was level with the ground.

To be honest I did not look at that with the ventilation and natural light. So I dont have the exact square footage of the room to figure it out.

The room was about 12x12 and the window was 42 wide slider and 32 high.
Reply With Quote
  #4 (permalink)  
Old 06-08-2007, 10:28 AM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,547
Re: Basement egress
Quote:
Originally Posted by Mike Huppi View Post
The room was about 12x12 and the window was 42 wide slider and 32 high.
The window is too small for the 8% minimum for natural light.

Which also makes half of the window too small for the 4% minimum for natural ventilation.

12' x 12' = 144 sf x 144 = 20,736 sq in

20,736 x 0.08 = 1,659 sq in ... 42" x 32" = 1,344 sq in (approximately 6-1/2% instead of 8%)

20,736 x 0.04 = 830 sq in ... 21" x 32" = 672 sq in (approximately 3% instead of 4%)
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #5 (permalink)  
Old 06-08-2007, 10:58 AM
Michael Greenwalt's Avatar
Michael Greenwalt Michael Greenwalt is offline
Member
 
Join Date: Mar 2007
Location: Junction City, KS
Posts: 112
Re: Basement egress
Because the window is at ground level the window size can be reduced to 5.0 sq. ft with the minimum length and width sizes met. The egress through the laundry and bathroom do not apply. Had one yesterday, rented out as an apartment with the only egress through a garage, no windows in basement. Unfortunatly the basment renters weren't there to get my explanation on the necessity for providing proper egress.
Reply With Quote
  #6 (permalink)  
Old 06-08-2007, 11:01 AM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,547
Re: Basement egress
Quote:
Originally Posted by Michael Greenwalt View Post
Because the window is at ground level the window size can be reduced to 5.0 sq. ft with the minimum length and width sizes met.
Did you notice this when I posted it above?

"The minimum opening size is 5.0 sq ft, and 21" by 32" = 672 sq in / 144 = 4.67 sq ft."

That window does not even make 5.0 sf. That's one of the problems.
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #7 (permalink)  
Old 06-08-2007, 07:49 PM
Mike Huppi Mike Huppi is offline
Member
 
Join Date: Mar 2007
Location: Aloha Oregon
Posts: 125
Re: Basement egress
Yes you are right thanks for the response Jerry.

I did put that there was no egress last night.

Thank you for your insight and response. I learn new things every day on here.
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Clogged basement floor drain. clayton bucek Plumbing System: Home Inspection and Commercial Inspection 5 06-10-2007 12:18 PM
Basement Wall Condensation Jon Randolph Building Interior: Home Inspection and Commercial Inspection 2 06-01-2007 08:21 PM
Insulate basement Mike Schulz Sub-Structure: Home Inspection and Commercial Inspection 3 05-04-2007 09:25 AM
Basement ceiling water damage Brian Hannigan Sub-Structure: Home Inspection and Commercial Inspection 0 03-22-2007 01:36 AM


All times are GMT -7. The time now is 07:30 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger