Registration is FREE!... and will get rid of this top message
Welcome to InspectionNews.net.
You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.
There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.
Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!
Registration is FREE, fast and easy so please, join InspectionNews today!
Why join InspectionNews? Read the Testimonials
Looking for Education? We recommend Casey, O'Malley and Associates

If you have any problems with the registration process or your account login, please contact us.
|
|

10-04-2009, 07:54 AM
|
 |
Member
|
|
Join Date: Sep 2009
Location: Wausau, WI.
Posts: 28
|
|
|
Smoke Detectors In New Condo Not Connected.
Inspected a condo yesterday that is 3-4 years old. Stopped by the sales office to let them know I was heading over to start. Realtor came in from another office, saw me and said that she was surprised that someone would get an inspection on new condos since everything is taken care of by the maintenance department.
On top of other fit and finish and leaking faucet stuff I found that none of the smoke detectors are electrically connected. They just mounted the detector on the junction box and did not hook any of them up.
Nice 
|
|

10-04-2009, 11:41 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Columbus GA
Posts: 778
|
|
|
Re: Smoke Detectors In New Condo Not Connected.
Around here smoke detectors are also required to be interconnected with battery backup.
__________________
Rick Cantrell
Columbus GA
|
|

10-04-2009, 12:45 PM
|
|
Member
|
|
Join Date: Feb 2008
Location: Caledon, Ontario
Posts: 1,131
|
|
|
Re: Smoke Detectors In New Condo Not Connected.
Well so much for the maintenance crew. Hope the place doesn't catch fire and someone is killed. Makes you wonder what is amiss in the other units.
Good find!
__________________
The value of experience is not in seeing much, but in seeing wisely. - Sir William Osler 1905
|
|

10-05-2009, 01:54 AM
|
|
Member
|
|
Join Date: May 2009
Location: Seattle
Posts: 133
|
|
|
Re: Smoke Detectors In New Condo Not Connected.
Originally Posted by Michael Carson
Inspected a condo yesterday that is 3-4 years old. Stopped by the sales office to let them know I was heading over to start. Realtor came in from another office, saw me and said that she was surprised that someone would get an inspection on new condos since everything is taken care of by the maintenance department.
On top of other fit and finish and leaking faucet stuff I found that
none of the smoke detectors are electrically connected.
They just mounted the detector on the junction box and did not hook any of them up.
Nice 
On top of that, the smoke alarm has no battery back-up, let alone an interconnecting parallel alarm conductor. I know WI State has adopted the smoke alarm 120Vac battery backup NFPA 72 Ch.11 requirement (1996) so this may have been a double violation. I notice that an AC whip is the interconnecting means and may not provide easy repair accessibility. I myself, would write it up requiring a hookup, but as a CYA just in case I would mention the missing battery and interconnecting conductor. A different smoke alarm may be needed. rbj
|
|

10-05-2009, 05:05 PM
|
 |
Member
|
|
Join Date: Sep 2009
Location: Wausau, WI.
Posts: 28
|
|
|
Re: Smoke Detectors In New Condo Not Connected.
Originally Posted by ben jacks
On top of that, the smoke alarm has no battery back-up, let alone an interconnecting parallel alarm conductor. I know WI State has adopted the smoke alarm 120Vac battery backup NFPA 72 Ch.11 requirement (1996) so this may have been a double violation. I notice that an AC whip is the interconnecting means and may not provide easy repair accessibility. I myself, would write it up requiring a hookup, but as a CYA just in case I would mention the missing battery and interconnecting conductor. A different smoke alarm may be needed. rbj
I did write it up as requiring hookup according to local ordinances with applicable municipal inspection. The reason the battery is not there is because I had to remove it to get to the screw and loosen it. I did that so I could slide the detector aside to show the wiring along with the alarm for the picture.
Thank you for the info, I forgot the actual Ch. 11 requirement section.
|
|

10-05-2009, 07:57 PM
|
 |
Member
|
|
Join Date: Feb 2009
Location: Southern Vancouver Island
Posts: 537
|
|
|
Re: Smoke Detectors In New Condo Not Connected.
You say the battery was installed so the unit would test ok, but not be hard wired???
Dang, now I'm wondering how many more are out there not wired just like that????? 
|
|

10-05-2009, 10:13 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
|
|
|
Re: Smoke Detectors In New Condo Not Connected.
Originally Posted by John Kogel
You say the battery was installed so the unit would test ok, but not be hard wired???
Dang, now I'm wondering how many more are out there not wired just like that????? 
John,
If they are hard-wired in and interconnected as required, not being wired in and having a battery will not trigger the other smoke detectors - only that one will go off.
That should be enough to write the smoke detectors up, and have the installation checked and corrected, which would include the wiring.
If hard-wired and actually connected, but not interconnected, the same thing would happen - only that one smoke detector would go off.
|
|

10-07-2009, 10:25 PM
|
 |
Member
|
|
Join Date: Feb 2009
Location: Southern Vancouver Island
Posts: 537
|
|
|
Re: Smoke Detectors In New Condo Not Connected.
Originally Posted by Jerry Peck
John,
If they are hard-wired in and interconnected as required, not being wired in and having a battery will not trigger the other smoke detectors - only that one will go off.
Thanks Jerry, that's ..........logical !!  
|
|