You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-24-2007, 06:13 AM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,071
Fire stopping/blocking in older homes
Older (102 years) two story home. First picture is looking down at attic floor, you can see down to first floor (at least) beside stack. Second is looking up from basement, you can see up to the second floor (at least), portions of the interior are exposed wood.

Presumably, there may be other such internal wall voids I can’t see below the attic floor and perhaps above duct runs in the basement.

Suggested wording for the recommendations for fire blocking/stopping of this sort of “chase”?

Also, would anyone here mention the possibility of other such passages?

BTW, the Tic-Tracer says that K&T headed down beside the stack is live….
Attached Images
File Type: jpg Chase1.jpg (65.1 KB, 44 views)
File Type: jpg Chase2.jpg (161.8 KB, 41 views)
Reply With Quote
Home inspection
  #2 (permalink)  
Old 07-24-2007, 06:42 AM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,546
Re: Fire stopping/blocking in older homes
I would mention that older homes were balloon framed, meaning that the wall studs went from the foundation to the roof, with the floors and ceilings on ledgers nailed to the studs, and that this creates a fire run for fire from the bottom to the top, and that especially for two story homes, this creates a chimney like effect and drafts upward quickly.

Then I would state that modern building methods found that fire stopping was necessary to reduce the risk of, and damage from, fires, and that most homes built today are platform framed where there the the foundation, the first floor platform, the first floor wall studs, then the second floor platform (or top plate and roof structure), all of which break off the stud cavities at every floor and ceiling.

I would follow that with 'And there is no practical way to go back and add fire stops to an older home which does not have fire stops, especially balloon framed homes.

You could then add that if the old knob and tube wiring were replaced with modern wiring, they could loose fill or foam fill the stud cavities with thermal insulation, which would not only help reduce energy costs, but also help stop the spread of fires and the drafts those fires create.

I know you know what balloon framing and platform framing is, but you would need to explain it to your client, so I included a brief description above also.

I.e., 'You are buying a fire trap, there is no practical way to fix it, but, not to worry, your fire trap is no worse than the fire trap of the same relative age next door or across town.'
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #3 (permalink)  
Old 07-24-2007, 08:17 AM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,071
Re: Fire stopping/blocking in older homes
Humm... thanks.
Reply With Quote
  #4 (permalink)  
Old 07-24-2007, 08:22 AM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,546
Re: Fire stopping/blocking in older homes
Quote:
Originally Posted by Michael Thomas View Post
Humm... thanks.
Or, you could just tell them that older homes do not have the fire blocking built into newer homes, but, hey, it has not burned down yet, besides, these older homes can't be all that bad, I mean, look out there, there are no fire trucks parked on this street waiting for these older homes to burn down. The fire department must think they are safe enough for normal response times.

Any better?
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #5 (permalink)  
Old 07-24-2007, 01:31 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,546
Re: Fire stopping/blocking in older homes
Michael,

Another about about fire stops in 100 year old homes ... fire stops after it reaches the roof ... unless it jumps to the house next door.

(sorry could not resist)
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Minnesota Requires Radon Mitigation In New Homes Bruce Breedlove Environmental, Pests, Health and Safety: Home Inspection and Commercial Inspection 3 05-10-2007 05:59 PM
Sears Catalog Homes Bruce Breedlove General Chit Chat: Home Inspectors & Commercial Inspectors 8 04-16-2007 05:03 PM
Plaintiffs claim homes poorly constructed, sue for repair costs - Merced Sun-Star Brian Hannigan Expert Witness and Defect Litigation: Home Inspection & Commercial Inspection 0 03-27-2007 12:03 AM


All times are GMT -7. The time now is 06:59 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger