InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 04-18-2007, 03:45 PM
wes owens wes owens is offline
Member
 
Join Date: Mar 2007
Location: Florence, SC
Posts: 91
needed a breeze in the shower
This light fixture complete with ceiling fan is about half way in and out of the shower as far as where the curtain rod hangs.
Would you write this up?

The reason I'm asking is because it is not directly over the shower and it is not enclosed by a shower door.
Attached Images
File Type: jpg showerfan.JPG (25.1 KB, 113 views)
__________________
"I reject your reality and substitute my own!" - A. S.

Absolute Home Inspections, LLC
Reply With Quote
FREA Home Inspector Insurance
  #2 (permalink)  
Old 04-18-2007, 03:49 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: needed a breeze in the shower
NO PART of it is allowed to be over the edge of the tub or even within 3 feet of the edge of the tub, and up to 8 feet high.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #3 (permalink)  
Old 04-18-2007, 03:51 PM
wes owens wes owens is offline
Member
 
Join Date: Mar 2007
Location: Florence, SC
Posts: 91
Re: needed a breeze in the shower
I didn't think so but wanted to be sure.
Thanks.
__________________
"I reject your reality and substitute my own!" - A. S.

Absolute Home Inspections, LLC
Reply With Quote
  #4 (permalink)  
Old 04-18-2007, 07:08 PM
Tim Moreira
 
Posts: n/a
Re: needed a breeze in the shower
I agree, same as the other post on the light fixture that some are arguing over
Reply With Quote
  #5 (permalink)  
Old 04-18-2007, 07:36 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: needed a breeze in the shower
Quote:
Originally Posted by Tim Moreira View Post
I agree, same as the other post on the light fixture that some are arguing over

The ceiling fan is worse ... some say you only measure 'to the fan' instead of 'to the tippy tip tippy of the blades'.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #6 (permalink)  
Old 04-18-2007, 08:15 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is offline
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,804
Re: needed a breeze in the shower
Ahh man, that's a Red Neck towel dryer!
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #7 (permalink)  
Old 04-18-2007, 11:41 PM
Richard Rushing's Avatar
Richard Rushing Richard Rushing is offline
Member
 
Join Date: Mar 2007
Location: Duncanville, Tx
Posts: 1,097
Re: needed a breeze in the shower
Don't know if any of you have ever been over anyone else's home that had a set up like that... but I have and had the pleasure of taking a shower there.

You freeze your kahonnies off with that freaking fan running!!!
Like George Costanza says, "There's shrinkage, SIGNIFICANT shrinkage!!!"

rr
Reply With Quote
  #8 (permalink)  
Old 04-20-2007, 02:57 PM
Michael Greenwalt's Avatar
Michael Greenwalt Michael Greenwalt is offline
Member
 
Join Date: Mar 2007
Location: Junction City, KS
Posts: 168
Re: needed a breeze in the shower
Borrowed, not mine, courtesy of someone on this board. Author unkonwn maybe Jerry. I like it so I saved it, good illustration
Attached Images
File Type: jpg elec-bathrm-8.jpg (126.2 KB, 85 views)
Reply With Quote
  #9 (permalink)  
Old 04-20-2007, 03:01 PM
Jim Luttrall Jim Luttrall is offline
Member
 
Join Date: Mar 2007
Location: Allen, Texas
Posts: 2,497
Re: needed a breeze in the shower
Michael,
Any idea what "A" "B" and "C" designate?
__________________
Jim Luttrall
www.MrInspector.net
Allen, Texas 75002
Reply With Quote
  #10 (permalink)  
Old 04-21-2007, 08:29 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
Jim That's what I would like to know, because I bet that A does not say that the fixtures shone in the picture have to be approved for "wet" locations.
Reply With Quote
  #11 (permalink)  
Old 04-21-2007, 11:21 PM
Tim Moreira
 
Posts: n/a
Re: needed a breeze in the shower
Not sure where Michael's picture is from, possibly an older version of the NEC but here is what is said in the:

02 NEC:

410.1 Scope.
This article covers luminaires (lighting fixtures), lampholders, pendants, incandescent filament lamps, arc lamps, electric-discharge lamps, the wiring and equipment forming part of such lamps, luminaires (fixtures), and lighting installations.

410.4 Luminaires (Fixtures) in Specific Locations.

(A) Wet and Damp Locations. Luminaires (fixtures) installed in wet or damp locations shall be installed so that water cannot enter or accumulate in wiring compartments, lampholders, or other electrical parts. All luminaires (fixtures) installed in wet locations shall be marked, “Suitable for Wet Locations.” All luminaires (fixtures) installed in damp locations shall be marked, “Suitable for Wet Locations” or “Suitable for Damp Locations.”

(D) Bathtub and Shower Areas. No parts of cord-connected luminaires (fixtures), hanging luminaires (fixtures), lighting track, pendants, or ceiling-suspended (paddle) fans shall be located within a zone measured 900 mm (3 ft) horizontally and 2.5 m (8 ft) vertically from the top of the bathtub rim or shower stall threshold. This zone is all encompassing and includes the zone directly over the tub or shower stall.

The intent of 410.4(D) is to keep cord-connected, hanging, or pendant luminaires and suspended fans out of the reach of an individual standing on a bathtub rim. This list of prohibited items recognizes that the same risk of electric shock is present for each one.

Exhibit 410.1 illustrates the restricted zone in which the specified luminaires, lighting track, and paddle fans are prohibited. This requirement applies to hydromassage bathtubs, as defined in 680.2, as well as other bathtub types and shower areas. See 680.43 for installation requirements for spas and hot tubs (as defined in 680.2) installed indoors.
Attached Images
File Type: jpg Tub%20Electric%20Restrictions.jpg (26.4 KB, 45 views)

Last edited by Tim Moreira : 04-21-2007 at 11:41 PM.
Reply With Quote
  #12 (permalink)  
Old 04-22-2007, 02:17 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
Thank you tim for posting the complete code, I still believe the picture you posted with the code allowes a surface mounted light over the tub without a wet location sticker. I would like to see proof that there is a fixture or vent fan that looks like the one in the picture that is for wet locations.
Reply With Quote
  #13 (permalink)  
Old 04-22-2007, 02:30 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
Just because the area is above a wet location does not mean that it is going to get wet. The ceiling above a tub is not designed to get wet and in most cases will never get wet. Just because you can see there is a possiabily that it could happen boes not make it un safe. A person is capable of doing anything stupid, but that does not mean that we are responsable for their stupity. That could apply to anything, if your going to protect your client from stupity then you better not stop with a light over the tub, you better list every stupid thing that could happen through out the whole house.
Reply With Quote
  #14 (permalink)  
Old 04-22-2007, 03:01 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: needed a breeze in the shower
Quote:
Originally Posted by Tony Mount View Post
Just because the area is above a wet location does not mean that it is going to get wet. The ceiling above a tub is not designed to get wet and in most cases will never get wet.
Actually, Tony, it does mean that. It means that, as the code dictates, that area "is subject to" getting wet.

Now, *of course*, the code cannot know *IF* an area deemed as a "wet location" will ever actually "get wet", but, when it does "get wet", the proper "wet location" fixture will have been installed.

"Just because you can see there is a possiabily that it could happen boes not make it un safe."

See above.

I must agree with you on one point (and you will love / hate this):

You could building a swimming pool with a light in it, not have it be an underwater light, and, *IF* "you never put water in the pool, and it was covered to protect it from rain, the pool would "never get wet", so, why bother installing a underwater rated pool light?

That fits right in with your logic. I mean, NO ONE HAS TO put water in the pool, right? I'll answer that for you "Ummm, yeah, ... aaaaaa ... right."
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #15 (permalink)  
Old 04-22-2007, 08:49 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
So what your saying is that your required to put cement board or what ever you use where your at on the ceilings above the tubs also. In Oklahoma even our outside walls and ceilings are not wet locations if they are covered with a 4 foot over hang. So not all areas are the same and codes don't apply across the country. We have open bulb flourscent light fixtures that are approved for wet locations that I would not install above a tub, but according to you they would be safer than the one with a cover posted on the other post.
Reply With Quote
  #16 (permalink)  
Old 04-22-2007, 08:52 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
I'm still looking to see code that says the ceiling above the tub is a wet location, so far it's just your opinion?
Reply With Quote
  #17 (permalink)  
Old 04-22-2007, 11:58 PM
Tim Moreira
 
Posts: n/a
Re: needed a breeze in the shower
Tony,

I think the argument here is with the height of that ceiling/fixture. If it is above:

Quote:
(D) Bathtub and Shower Areas. No parts of cord-connected luminaires (fixtures), hanging luminaires (fixtures), lighting track, pendants, or ceiling-suspended (paddle) fans shall be located within a zone measured 900 mm (3 ft) horizontally and 2.5 m (8 ft) vertically from the top of the bathtub rim or shower stall threshold. This zone is all encompassing and includes the zone directly over the tub or shower stall.
Then any light fixture/fan that meets the code is OK.

The question is *what is the height of Wes's ceiling fan (blades) and light fixture*?

Does it comply with this and the other sections? If yes then they are OK, if no well then...
Reply With Quote
  #18 (permalink)  
Old 04-23-2007, 05:18 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
The fan in the picture is not allowed if the ceiling is not above 8 ft above the rim of the tub, however a surface mounted light could be installed in its place without a wet location sticker if it has an enclosed globe.
Reply With Quote
  #19 (permalink)  
Old 04-23-2007, 07:16 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: needed a breeze in the shower
Quote:
Originally Posted by Tony Mount View Post
The fan in the picture is not allowed if the ceiling is not above 8 ft above the rim of the tub, however a surface mounted light could be installed in its place without a wet location sticker if it has an enclosed globe.
Tony,

I'll break that down for you to understand, possibly, if you really want to, otherwise you will just continue to blow this off. It's up to you.

"The fan in the picture is not allowed if the ceiling is not above 8 ft above the rim of the tub,"

Partially right.

You have the "8 feet" part right, but not where you measure to. The bottom bottomy thingy on the ceiling fan needs to be "8 feet* above the flood level rim of the tub (the overflow edge).

"however a surface mounted light could be installed in its place ... "

Correct on that part.

"without a wet location sticker if it has an enclosed globe."

Incorrect on that part.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #20 (permalink)  
Old 04-24-2007, 02:45 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
I agree except for the wet location sticker, if the ceiling is sheetrock no sticker needed.
Reply With Quote
  #21 (permalink)  
Old 04-24-2007, 04:40 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 3,655
Re: needed a breeze in the shower
Tony,

Curious.

Why would you not think the ceiling above the tub is not considered a wet location?

Have you not ever seen the steam and humidity collect on the ceilings above a tub or shower? or a leaking shower head spraying water up onto the ceiling?
__________________
This space is now available for sale or for lease. Contact your broker if interested. Serious inquiries only.
Reply With Quote
  #22 (permalink)  
Old 04-24-2007, 07:56 PM
Tony Mount Tony Mount is offline
Member
 
Join Date: Mar 2007
Location: Mustang
Posts: 186
Re: needed a breeze in the shower
The garages are wet locations requiring GFCI outlets but NO wet location lights. Go figure?
Reply With Quote
  #23 (permalink)  
Old 04-24-2007, 08:35 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: needed a breeze in the shower
Quote:
Originally Posted by Tony Mount View Post
The garages are wet locations requiring GFCI outlets but NO wet location lights. Go figure?
Huh?

Who said garage are wet locations?

Jeez, no wonder you don't understand what is being said in the posts above.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
F.I.R.E. provides fireplace education, consulting services, fire investigation and litigation support across the United States.
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Realtor gets much-needed lesson in disclosure - Upstate House Brian Hannigan Inspection News From Around The Net 11 07-20-2008 01:28 PM
Flow restrictors affect shower temps - Chicago Daily Herald Brian Hannigan Inspection News From Around The Net 0 04-08-2007 12:00 PM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 12:50 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger