You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

09-25-2007, 06:22 PM
|
 |
Administrator
|
|
Join Date: Mar 2007
Location: San Clemente, CA
Posts: 610
|
|
|
PA man says improperly installed dryer vent caused fire - Southeast Texas Record
InspectionNews has found this article about defect litigation or expert witness work that may be of interest to you.
PA man says improperly installed dryer vent caused fire
Southeast Texas Record, TX - 4 hours ago
He has broad experience in large-loss subrogation, fire cause and origin litigation, products liability litigation, construction defect litigation, ...
More...
|
|

09-25-2007, 07:24 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,644
|
|
|
Re: PA man says improperly installed dryer vent caused fire - Southeast Texas Record
Boy, is that a mouthful of poorly chosen words or what?
"Port Arthur resident Frederick Goenne and his insurance company, Allstate, say the fire that claimed his home was started in a faulty dryer vent, which was built by A&W Aluminum, also known as Windell Broussard Homes."
What did A&W Aluminum, also known as Windell Broussard Homes, build?
A) The dryer vent?
B) The home?
C) Both?
The rest is not much better and offer no information as to what material the dryer vent was constructed from or how it was installed.
|
|

09-25-2007, 08:11 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Dallas Home Inspections
Posts: 326
|
|
|
Re: PA man says improperly installed dryer vent caused fire - Southeast Texas Record
Interesting to say the least. The author "David Yates" is a broker/Realtor/builder/talk show host/energy specialist/entrepreneur ... etc. (I attribute those descriptions to Mr. Yates himself).
He has radio shows on Saturdays in both the Houston and Dallas/Ft. Worth markets and maybe San Antonio as well.

|
|

09-26-2007, 06:30 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,073
|
|
|
Re: PA man says improperly installed dryer vent caused fire - Southeast Texas Record
A Realtor who refers to me regularly recently had a dryer catch fire during a pre-closing walk through...
Probably half the dryer vents I see are incorrect in some way. I write them up, but I also tell my client: "There are around 15,000 dryer fires a year. Many (some say most) fires result from lint build-ups. If lint builds up, and catches fire, the *best* you can hope for is that a properly constructed vent system will keep the fire from spreading. So the best way to protect your family from these fires is to keep them from starting in the first place. To do that, you need to remember to do some simple maintenance, starting with cleaning the lint filter after *every* use...
And the first first thing that comes to my mind when I read that story is....
|
|

09-26-2007, 11:30 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,644
|
|
|
Re: PA man says improperly installed dryer vent caused fire - Southeast Texas Record
Originally Posted by Michael Thomas
And the first first thing that comes to my mind when I read that story is....
Michael,
I'd say it's a pretty safe bet that the *METAL* (even if aluminum) dryer vent 'did not catch on fire', by itself or otherwise.
It may not have 'contained' the fire, especially if of aluminum, but the 'dryer vent' did not 'cause' the fire.
|
|

09-26-2007, 12:39 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Land of Gar, TX
Posts: 391
|
|
|
Re: PA man says improperly installed dryer vent caused fire - Southeast Texas Record
__________________
badair http://www.adairinspection.com Garland, TX 75042
Residential-Commercial-Construction-EIFS-Infrared Thermography
life is the random lottery of events followed by numerous narrow escapes
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Could not locate dryer vent termination |
M Kelekci |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
9 |
09-23-2007 07:48 AM |
| Dryer exhaust vent |
RobertSmith |
Built-In Appliances and Systems: Home Inspection and Commercial Inspection |
13 |
08-23-2007 05:07 PM |
| dryer vent |
Jeff Eastman |
Built-In Appliances and Systems: Home Inspection and Commercial Inspection |
6 |
05-24-2007 02:35 PM |
| Dryer Vent Next To Condensing Coil |
imported_John Smith |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
12 |
04-29-2007 02:52 PM |
| Chimney fire hits home on Mariposa - Enterprise-Record |
Brian Hannigan |
Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection |
0 |
03-27-2007 10:19 AM |
All times are GMT -7. The time now is 07:37 AM.
| | |
|