Power Gate Safety
Anyone have information on residential gates?
I come across driveway gate on occasion and am taken aback that there are few if any safety devices. I am wondering if there are any safety standards similar to garage door operators.
Similar Threads:Last edited by Jim Luttrall; 03-04-2010 at 01:54 PM.
-
03-04-2010, 01:55 PM #2
Re: Power Gate Safety
Consumer Product Safety Commission
CPSC worked with Underwriters Laboratories (UL) to develop the tougher safety standard that requires automatic gates to have at least two mechanisms to prevent entrapment. These provisions are similar to the standards in effect for automatic garage doors. The standard, which UL adopted in March 2000, requires a sensing device that will reverse the gate if it encounters an obstruction when opening or closing; and a secondary sensing mechanism, such as an electric eye or an edge sensor that will reverse the gate if an obstruction is detected.
Additional safety measures related to gate installation include:
GTO Automatic Gate Openers - UL325 Article
- Elimination of all gaps over 2.25 inches.
- Installation of controls far enough from the gate so users cannot come into contact with the gate while operating the controls.
- Installation of controls where the user has full view of the gate operation.
- Elimination of pinch points.
- Installation of guarding on exposed rollers.
- Posting of warning signs on each side of the gate.
Last edited by Wayne Carlisle; 03-04-2010 at 01:57 PM. Reason: Added web site
-
03-04-2010, 02:16 PM #3
Re: Power Gate Safety
Great, just what I was looking for. I know it is a voluntary listing but at least it is a standard of what should be present for safety.
Thanks!
-
03-04-2010, 05:34 PM #4
-
03-04-2010, 05:56 PM #5
Re: Power Gate Safety
"How does The Fire Department feel about non access to the Residence?"
Same as a locked door. If they want in,they are comming in.
' correct a wise man and you gain a friend... correct a fool and he'll bloody your nose'.
-
03-04-2010, 06:00 PM #6
Re: Power Gate Safety
Probably the same as when I was in South Florida and talked with a Fire Chief about a development where the EERO all went to rear yards with fences and no gates for a way out, only option was to jump the fence.
His reply was "Ever seen how wide of an opening a fire truck makes when it drives over a fence? REAL easy to walk or run through." (Yes, he was smiling big time when he told me that. )
-
03-04-2010, 07:17 PM #7
Re: Power Gate Safety
It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
Billy J. Stephens HI Service Memphis TN.
-
03-04-2010, 07:18 PM #8
Re: Power Gate Safety
Most of what I see is gates at the rear entry driveway. Guests and firemen come to the front door
-
03-04-2010, 07:23 PM #9
-
03-04-2010, 07:56 PM #10
Re: Power Gate Safety
"The owner of premises at or upon which a governmental body requires the designation and maintenance of a fire lane,"
Billy
Are you saying that a governmental body requires this on residential privet property.
I see fire lanes at the mall, grocery store and other shopping centers.
' correct a wise man and you gain a friend... correct a fool and he'll bloody your nose'.
-
03-04-2010, 07:58 PM #11
-
03-04-2010, 08:54 PM #12
Re: Power Gate Safety
It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
Billy J. Stephens HI Service Memphis TN.
-
03-04-2010, 09:33 PM #13
Re: Power Gate Safety
-
03-12-2010, 07:02 PM #14
Re: Power Gate Safety
Many of these gates are equipped with an automatic opener if it detects a certain tone emitted by the siren of the responding agency. As far as any specific requirement to allow access by other means, it would be up to the emergency response agency that has jurisdiction in that area.
-
03-12-2010, 07:08 PM #15
Re: Power Gate Safety
Seems strange they would be relying on electricity to open the gate from a house which was on fire and from which the first thing they likely did was disconnect all power to the house - many fire departments do not spray water on energized structures, really increases the hazards the firefighters encounter.
-
03-12-2010, 07:17 PM #16
Re: Power Gate Safety
.
Gotta Open the Gate ( if it blocks access ) to get to the Structure in order to Cut the Power.
Think garage door opener or the Signal sent to change the traffic lights on the response rounding the corner the gate opens before the Equipment arrives.
* if not see option 2.
.
It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
Billy J. Stephens HI Service Memphis TN.
-
03-15-2010, 08:37 AM #17
Re: Power Gate Safety
Power driven security gates was always a disclaimer when I was inspecting.
A little boy had his arm torn off when playing around one of them. When asked by clients if the local building dept. allowed electric gates I usually replied; "Nah, they only allow draw-bridges." (I got a lot of funny looks)
How about home owners who install padlocks on the electrical service panels?
That's why all fire trucks carry bolt cutters and the very first thing they do when arriving at a burning building is shut off the power and it ain't by throwing circuit breakers.
Jerry McCarthy
Building Code/ Construction Consultant
-
04-03-2010, 01:20 AM #18
Re: Power Gate Safety
In my thought power gates should be based on functionality of automatic opening and closing in the slider manner. Explosive detective components should be shifted on gates. If anyone holds such the things, it raises sound. Such gates are highly protected.
-
04-03-2010, 06:48 AM #19
Re: Power Gate Safety
gate info is toward the bottom
DASMA Door and Access Systems Manufacturers Association
other info may come in useful
badair http://www.adairinspection.com Garland, TX 75042
Commercial-Residential-Construction-EIFS-Stucco-ACMV-Infrared Thermography
life is the random lottery of events followed by numerous narrow escapes...accept the good
-
04-03-2010, 07:03 AM #20
-
04-03-2010, 07:32 AM #21
Re: Power Gate Safety
Good info Barry, I pulled this out as useful to the inspector and consumer.