    Cool New type Hangar for Dryer Duct ?

    Here is a new idea for supporting a dryer duct.
    A nearby electrical bx line wound into a loop.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    OREP Insurance

  2. #2
    Join Date
    Mar 2007
    Location
    Charlotte NC Licensed in NC and SC
    Posts
    597

    Default Re: New type Hangar for Dryer Duct ?

    I hope that is not a dryer duct........but you know that already I hope.

    Bruce King, B.A. King Home Inspections, LLC
    www.BAKingHomeInspections.com
    Certified Master Inspector, Independent Inspectorwww.IndependentInspectors.org

  3. #3
    Join Date
    Jun 2010
    Location
    Vancouver
    Posts
    202

    Default Re: New type Hangar for Dryer Duct ?

    Sal sorry to say but that is not earth shattering nor is it worth posting. Yes it is not done right but we really want to see strange or things that you need help with. no offence but that was too easy and straight forward and not worth posting.


  4. #4
    Join Date
    Feb 2010
    Location
    St. John, KS
    Posts
    52

    Thumbs up Re: New type Hangar for Dryer Duct ?

    Quote Originally Posted by Sal Castro View Post
    Here is a new idea for supporting a dryer duct.
    A nearby electrical bx line wound into a loop.


    I hope you wrote up the defect of this dryer duct!? I'm sure the report was IAW the current IMC Codes!? If not I have attached a copy:

    Good catch Sal!!

    Attached Files Attached Files

  5. #5
    Join Date
    Feb 2008
    Location
    Chicago IL
    Posts
    2,048

    Default Re: New type Hangar for Dryer Duct ?

    And ...
    - the electric line laying on the copper pipe
    - is that plywood/osb between the 2x sill plate and block, any signs of rot or water intrusion?
    - what's the point of the insulation scraps, when the floor isn't insulated, did you feel any breezes, siding issues?

    www.aic-chicago.com
    773/844-4AIC
    "The Code is not a ceiling to reach but a floor to work up from"

  6. #6
    Join Date
    Jul 2007
    Location
    Elmont, NY
    Posts
    22

    Default Re: New type Hangar for Dryer Duct ?

    Yes, I wrote it up with an added note about unnecessary heat and stress on the wiring as well. Easy fix.

    Just thought I would post it to give some a little chuckle.


  7. #7
    Join Date
    Jul 2007
    Location
    Elmont, NY
    Posts
    22

    Default Re: New type Hangar for Dryer Duct ?

    Quote Originally Posted by Markus Keller View Post
    And ...
    - the electric line laying on the copper pipe
    - is that plywood/osb between the 2x sill plate and block, any signs of rot or water intrusion?
    - what's the point of the insulation scraps, when the floor isn't insulated, did you feel any breezes, siding issues?
    no osb, no rot. They had put an extension and crawlspace behind that original 1950 foundation wall so i guess they felt the need for insulation.


  8. #8
    Join Date
    Mar 2007
    Location
    Spring Hill (Nashville), TN
    Posts
    5,851

    Default Re: New type Hangar for Dryer Duct ?

    Quote Originally Posted by Bill Hetner View Post
    Sal sorry to say but that is not earth shattering nor is it worth posting. Yes it is not done right but we really want to see strange or things that you need help with. no offence but that was too easy and straight forward and not worth posting.
    I hope this is a tongue n cheek comment.....

    Scott Patterson, ACI
    Spring Hill, TN
    www.traceinspections.com

  9. #9

    Default Re: New type Hangar for Dryer Duct ?

    Quote Originally Posted by Sal Castro View Post
    Here is a new idea for supporting a dryer duct.
    A nearby electrical bx line wound into a loop.
    Yep, not right. Very creative! But of course the dryer flex should not be there in the first place.

    True Professionals, Inc. Property Consultant
    877-466-8504

  10. #10
    Join Date
    Jul 2010
    Location
    Washington
    Posts
    70

    Default Re: New type Hangar for Dryer Duct ?

    There should be rigid metal ducting in that space supported every 4'. Much less friction and more sturdy than the flex vinyl.


  11. #11
    mike huntzinger's Avatar
    mike huntzinger Guest

    Default Re: New type Hangar for Dryer Duct ?

    Along with Luc commit it is also a fire issue with the vinyal flex duct


  12. #12
    Inspector 3500's Avatar
    Inspector 3500 Guest

    Default Re: New type Hangar for Dryer Duct ?

    It's also an electrical code violation to support anything from the conduit unless its associated with wiring within.