Thread: microwave vent

  1. #1
    Join Date
    Mar 2007
    Location
    Philadelphia PA
    Posts
    3,177

    Default microwave vent

    Can't remember if I've brought this up before...

    I keep running into microwave ovens over ranges where it seems like they were installed to vent to the outside, but there is no duct, so the air has nowhere to go and just kind of leaks out around the top.

    I know that most if not all of them are designed to go either way, either venting outside (superior, obviously) or re-circulating inside. You change an internal baffle to set it up for one or the other.

    I seems the baffle is positioned for external venting, but there's no duct.

    Anyone else run into this very often?

    Inspection Referral
    "There is no exception to the rule that every rule has an exception." -James Thurber, writer and cartoonist (1894-1961)
    www.ArnoldHomeInspections.com

  2. #2
    Join Date
    Mar 2007
    Location
    Orlando, FL
    Posts
    1,592

    Default Re: microwave vent

    I see it frequently, so it seems people aren't reading the installation instructions very well.

    Dom.


  3. #3
    Join Date
    Mar 2007
    Location
    Philadelphia PA
    Posts
    3,177

    Default Re: microwave vent

    Quote Originally Posted by Dom D'Agostino View Post
    I see it frequently, so it seems people aren't reading the installation instructions very well.

    Dom.
    The ovens probably come with the baffle in the "vent outside" position, eh?

    "There is no exception to the rule that every rule has an exception." -James Thurber, writer and cartoonist (1894-1961)
    www.ArnoldHomeInspections.com

  4. #4
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: microwave vent

    The problem with that is that grease and stuff can build up between the microwave oven and the wall behind and the cabinet above.

    It is easy enough to correct as I believe all that needs to be done is to remove the microwave, and, if the blower is facing up as it was likely shipped, rotate the blower opening from facing up to facing the front; if the blower is facing the rear, the blower unit may need to be lifted up out of the top rotated 180 degrees. then lowered back into the unit, then rotated to face the front. I believe that is how it is done on GE units.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  5. #5
    Join Date
    Mar 2007
    Location
    Plano, Texas
    Posts
    4,245

    Default Re: microwave vent

    Yep, see it wrong many times. Simple fix but easy to miss if you don't check it closely.

    Jim Luttrall
    www.MrInspector.net
    Plano, Texas

  6. #6
    Join Date
    Feb 2009
    Location
    Southern Vancouver Island
    Posts
    4,607

    Default Re: microwave vent

    The vent to the outside often, usually, has a hinged flap to keep prevent a cold draft. So even when the duct is installed, if the vent to indoors is open, the air will bypass the duct and blow back into the room.

    A high-end range hood with two fans, one fan was dead, so air from the other fan was blowing out and blowing down on the gas burners. The flap in the duct was jammed shut.

    But the cheap range hood in this last house I did had the funny setup, no duct, but with a cover over the front grill. The poor little fan is busting a gut to accomplish nothing.

    Last edited by John Kogel; 03-09-2014 at 04:07 PM.
    John Kogel, RHI, BC HI Lic #47455
    www.allsafehome.ca

  7. #7
    Join Date
    Mar 2007
    Location
    Orlando, FL
    Posts
    1,592

    Default Re: microwave vent

    Quote Originally Posted by John Arnold View Post
    The ovens probably come with the baffle in the "vent outside" position, eh?
    Seem to be shipped in "upper vent" direction. Most of the ones I see installed (both right and wrong) are GE, followed by Whirlpool.


  8. #8
    Join Date
    Mar 2007
    Location
    New Mexico
    Posts
    1,352

    Default Re: microwave vent

    I find about one a month, maybe more. Seems to be a pretty common goof by the homeowner or installed.

    Jim Robinson
    New Mexico, USA

  9. #9
    Join Date
    Jun 2008
    Location
    Maryland
    Posts
    1,096

    Default Re: microwave vent

    I see microwave fan venting issues alot. The last two were configured to recirculate into the kitchen. The problem was there were over sized (depth) cabinets installed that completely blocked the discharge at the upper front of the units. These were new home builder errors, not homeowner.


  10. #10
    Join Date
    Dec 2008
    Location
    Maryland
    Posts
    2,809

    Default Re: microwave vent

    Jerry is correct. Simple correction. Two bolts in cabinet and hung on bracket attached to wall. 2 screws to remove and rotate blower. BUT< FOR THE NOVICE, YOU NEED 2 PEOPLE TO REMOVE MICROWAVE AND REINSTALL WITHOUT IT DROPPING ON STOVE.

    Stuff happens. Always disconcerting that it wasn't picked up on installation or on first testing.


  11. #11
    Join Date
    Mar 2007
    Location
    Houston, Texas
    Posts
    294

    Default Re: microwave vent

    Another issue that I run into all the time is improper connection and sealing of the vent piping when it is intended to be vented to the outside. More often than not I find that there is cabinet material being used as part of the duct system.

    The metal transition between the unit's outlet will be missing and there is at best a half-hearted attempted to just tape it all up from the inside. When you turn on the unit there is air leaking out between the top of the microwave and the cabinet bottom below.

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images

  12. #12
    Join Date
    Mar 2007
    Location
    Spring Hill (Nashville), TN
    Posts
    5,851

    Default Re: microwave vent

    I see microwave venting problems often.... I also find vent fans venting into their fancy overhead wood chase that is suppose to cover the vent pipe but they were never vented to the outside, they are just blowing into the wood chase!

    Scott Patterson, ACI
    Spring Hill, TN
    www.traceinspections.com

  13. #13
    Join Date
    Sep 2007
    Location
    Fredericksburg, VA
    Posts
    895

    Default Re: microwave vent

    Quote Originally Posted by John Dirks Jr View Post
    I see microwave fan venting issues alot. The last two were configured to recirculate into the kitchen. The problem was there were over sized (depth) cabinets installed that completely blocked the discharge at the upper front of the units. These were new home builder errors, not homeowner.
    Yes- I've seen that in new construction too. It's piece-work labor. In this area most can't read or speak English and I doubt they can read Spanish either because most everything comes with Spanish instructions.

    The above statements are expressed solely as my opinion and in all probability will conflict with someone else's.
    Stu, Fredericksburg VA

  14. #14
    Join Date
    Feb 2009
    Location
    Southern Vancouver Island
    Posts
    4,607

    Default Re: microwave vent

    We have mostly English speaking and a few French Canadians and they still get them installed wrong. The funniest one is the baffle they forget to take out of the box, now gone to the landfill.

    John Kogel, RHI, BC HI Lic #47455