Results 1 to 12 of 12
-
08-25-2012, 03:11 PM #1
Washing machine located within 6' of service panel.
hello,
i was wondering why a washing machine would be located about 4' from the electric service panel. how can this be code? any input is greatly appreciated!
-nate-
Similar Threads:
-
08-25-2012, 03:59 PM #2
Re: Washing machine located within 6' of service panel.
It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
Billy J. Stephens HI Service Memphis TN.
-
08-25-2012, 04:41 PM #3
Re: Washing machine located within 6' of service panel.
thanks for your responses! i feel my question may need some more explanation. the NEC requires a GFCI outlet if it is located within 6' of a water source (i'm pretty sure we all know this). however, in this situation, the entire service panel is within 6' of a water source. and not just any water source, but one that has a tendency to spring a leak from time to time (i assume that's why they came out with the "no burst" supply lines for washing machines).
-
08-25-2012, 04:56 PM #4
-
08-25-2012, 05:33 PM #5
-
08-25-2012, 07:27 PM #6
-
08-26-2012, 07:43 AM #7
-
08-26-2012, 08:20 AM #8
Re: Washing machine located within 6' of service panel.
210.8 Ground-Fault Circuit-Interrupter Protection for Personnel. Ground-fault circuit-interruption for personnel shall be provided as required in 210.8(A) through (C). The
ground-fault circuit-interrupter shall be installed in a readily accessible location.
Informational Note: See 215.9 for ground-fault circuit interrupter
protection for personnel on feeders.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20- ampere receptacles installed in the locations specified in 210.8(A)(1) through (8) shall have ground-fault circuit interrupter protection for personnel.
(1) Bathrooms
(2) Garages, and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas,
and areas of similar use
(3) Outdoors
Exception to (3): Receptacles that are not readily accessible
and are supplied by a branch circuit dedicated to
electric snow-melting, deicing, or pipeline and vessel heating
equipment shall be permitted to be installed in accordance
with 426.28 or 427.22, as applicable.
(4) Crawl spaces — at or below grade level
(5) Unfinished basements — for purposes of this section, unfinished basements are defined as portions or areas of the basement not intended as habitable rooms and limited to storage areas, work areas, and the like
Exception to (5): A receptacle supplying only a permanently installed fire alarm or burglar alarm system shall not be required to have ground-fault circuit-interrupter
protection.
Informational Note: See 760.41(B) and 760.121(B) for power
supply requirements for fire alarm systems.
Receptacles installed under the exception to
210.8(A)(5) shall not be considered as meeting the
requirements of 210.52(G).
6) Kitchens— where the receptacles are installed to serve the counter top surfaces
(7) Sinks — located in areas other than kitchens where receptacles are installed within 1.8 m (6 ft) of the outside edge of the sink
(8) Boathouses
I put the exceptions in red for you.
You will notice I underlined a section in #6 as the way it is worded it opens the door for a receptacle to be within 6' of a Kitchen sink and NOT be GFCI protected. GFCI protection is only required if the receptacle is installed to serve the counter top.
-
08-26-2012, 08:31 AM #9
Re: Washing machine located within 6' of service panel.
Last edited by Brad Richter; 08-26-2012 at 08:41 AM.
-
08-26-2012, 09:11 AM #10
Re: Washing machine located within 6' of service panel.
All answers based on unamended National Electrical codes.
-
08-26-2012, 09:20 AM #11
-
08-26-2012, 09:59 AM #12
Re: Washing machine located within 6' of service panel.
As it is not for the countertop, no GFI protection required.
I think it might if it was within 6' of a wet bar, but not in the kitchen. This might have been an upcoming change.
All answers based on unamended National Electrical codes.
Bookmarks