07-07-2008, 07:56 AM #1
Funky eletrical stuff
Hey guys had an inspection on a flip that was bulit in 1923... the service box has several questionable items... there are two 50 amp breakers attached to the bus and then back wired to the bus... any ideas for the reason? Also called out the service heads... do these look Kosher? Also do call out no main breaker on something this old. thanks Bill
Similar Threads:Last edited by William Slade; 07-07-2008 at 08:29 AM. Reason: another pic
-
07-07-2008, 08:16 AM #2
Re: Funky eletrical stuff
That's a split bus Federal Pacific panel. Most of us would call for replacement just because it is Federal Pacific.
-
07-07-2008, 08:29 AM #3
Re: Funky eletrical stuff
Looks like Aluminum wire also. Ditto John Arnold.
-
07-07-2008, 08:39 AM #4
Re: Funky eletrical stuff
I see stranded aluminum, but not solid.
Also, looks like there is a non-FPE breaker, but that might be a good thing!
-
07-07-2008, 08:41 AM #5
Re: Funky eletrical stuff
Thanks for the info.... any ideas for the 50amp being wired back to the bus? b
-
07-07-2008, 08:45 AM #6
Re: Funky eletrical stuff
That's the split bus. It's kind of like two panels in one. Usually the 240 circuits are on the top, and the branch circuits on the bottom being fed from a 240 above.
If you search on "split bus" in the archives you'll find a bunch of threads about it.
InspectionNews.com - Home Inspection Home Inspector Inspection Report
-
07-07-2008, 08:47 AM #7
Re: Funky eletrical stuff
Hey man thanks for the info... sorry I can't seem to get the rest of my pic's to take on my original thread... but maybe another time...b