    Default 3 way switch at stairways.

    Can anyone quote me the NEC code regarding 3 way switch at the top and bottom of stairs. Is there any limitation on that, such as 3 or more risers, etc?

    Similar Threads:
    OREP Insurance

  2. #2
    Join Date
    Mar 2007
    Location
    Tampa, Fl
    Posts
    155

    Default Re: 3 way switch at stairways.

    I think I got my answer.

    (c) Where one or more lighting outlet(s) are installed for interior stairways, there shall be a wall switch at each floor level, and landing level that includes an entry way, to control the lighting outlet(s) where the stairway between floor levels has six risers or more.