1. 04-16-2007
    Views:
    82,718

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. A good Zinsco???

    Started by Rick Bunzel, 08-26-2017 03:58 PM
    • Replies: 18
    • Views: 3,364
    11-17-2017, 12:03 AM Go to last post
  2. electric shock on dishwasher

    Started by Ben Im, 09-07-2017 10:17 PM
    • Replies: 3
    • Views: 931
    11-11-2017, 03:20 PM Go to last post
  3. What's up with this panel? Amp? No disco?

    Started by Crosseyes, 11-05-2017 10:22 AM
    • Replies: 5
    • Views: 1,409
    11-06-2017, 09:47 AM Go to last post
    • Replies: 15
    • Views: 1,679
    11-06-2017, 05:41 AM Go to last post
  4. Condo panel and transfer switch question

    Started by HJ Gallego, 10-30-2017 10:42 PM
    • Replies: 12
    • Views: 1,772
    11-03-2017, 12:18 PM Go to last post
  5. Bonding of metal piping systems

    Started by Ken Amelin, 10-22-2017 08:14 AM
    • Replies: 4
    • Views: 893
    10-22-2017, 03:32 PM Go to last post
  6. Question Hanging Bulbs Code

    Started by Stuart S, 10-09-2017 03:29 PM
    fixtures, lighting
    • Replies: 3
    • Views: 1,611
    10-11-2017, 07:02 AM Go to last post
    • Replies: 15
    • Views: 634
    10-08-2017, 06:32 AM Go to last post
  7. Equipment grounds are bundled together

    Started by Sam Morris, 09-18-2017 04:33 PM
    • Replies: 1
    • Views: 1,888
    09-18-2017, 04:41 PM Go to last post
  8. GEC question

    Started by ROBERT YOUNG, 09-14-2017 06:05 AM
    • Replies: 10
    • Views: 838
    09-15-2017, 10:21 AM Go to last post
  9. Outlet "Tester" sampler panel

    Started by Bob Sisson, 09-12-2017 01:52 PM
    • Replies: 3
    • Views: 471
    09-12-2017, 09:22 PM Go to last post
  10. Canada gets this right, too bad the US doesn't

    Started by Jerry Peck, 08-25-2017 08:53 AM
    • Replies: 2
    • Views: 399
    08-26-2017, 01:40 PM Go to last post
  11. Bonding question

    Started by ROBERT YOUNG, 08-24-2017 05:00 AM
    • Replies: 13
    • Views: 642
    08-26-2017, 06:01 AM Go to last post
  12. HI training

    Started by Brad Richter, 08-22-2017 04:00 PM
    • Replies: 4
    • Views: 503
    08-23-2017, 06:17 PM Go to last post
  13. Main Lug labeled 2-250

    Started by Sam Morris, 07-27-2017 08:20 PM
    • Replies: 9
    • Views: 3,485
    07-31-2017, 07:02 PM Go to last post
  14. Unknown Gizmo?

    Started by Michael Chambers, 07-31-2017 12:53 AM
    • Replies: 7
    • Views: 505
    07-31-2017, 05:06 PM Go to last post
  15. Service equipment height.

    Started by ROBERT YOUNG, 07-17-2017 11:22 AM
    • Replies: 9
    • Views: 1,867
    07-19-2017, 09:07 PM Go to last post
  16. 240 volt breakers

    Started by Richard Roshak, 06-26-2017 04:45 PM
    • Replies: 16
    • Views: 2,459
    07-08-2017, 01:17 PM Go to last post
    • Replies: 5
    • Views: 2,469
    07-08-2017, 02:26 AM Go to last post
    • Replies: 23
    • Views: 4,226
    07-05-2017, 06:43 PM Go to last post
  17. Bundled conductors

    Started by Ken Amelin, 06-13-2017 01:57 PM
    • Replies: 15
    • Views: 2,590
    06-27-2017, 01:49 PM Go to last post
    • Replies: 23
    • Views: 2,239
    06-27-2017, 06:14 AM Go to last post
  18. Tap for subpanel into main lug

    Started by Ernie Simpson, 06-08-2017 06:04 PM
    • Replies: 14
    • Views: 1,287
    06-26-2017, 09:37 PM Go to last post
    • Replies: 12
    • Views: 1,543
    06-25-2017, 06:22 PM Go to last post
  19. Sub-panel wiring

    Started by Richard Roshak, 06-08-2017 05:16 PM
    • Replies: 8
    • Views: 1,263
    06-25-2017, 03:48 PM Go to last post
  20. Stairway lights and hallway lights are tied.

    Started by Ben Im, 06-06-2017 10:45 PM
    end, hallway, light, lights, stairway
    • Replies: 7
    • Views: 1,188
    06-08-2017, 12:35 PM Go to last post
  21. Double taped breakers

    Started by Don Hawley, 05-07-2017 12:32 PM
    agent, breakers, double, provide, reference;
    • Replies: 7
    • Views: 2,725
    06-02-2017, 09:07 PM Go to last post
  22. Generator lock out switch.

    Started by Ken Amelin, 05-11-2017 08:49 AM
    • Replies: 6
    • Views: 2,242
    05-26-2017, 01:50 PM Go to last post
  23. Green Oxidation in Service Panel

    Started by Lon Henderson, 05-01-2017 05:15 PM
    • Replies: 4
    • Views: 2,777
    05-04-2017, 08:18 AM Go to last post
    • Replies: 9
    • Views: 2,483
    05-04-2017, 06:04 AM Go to last post
  24. Transfer Switch

    Started by Gunnar Alquist, 04-14-2017 02:03 PM
    • Replies: 16
    • Views: 3,314
    04-25-2017, 06:59 AM Go to last post
  25. Transfer switch

    Started by Scott Turner, 04-21-2017 08:11 PM
    • Replies: 0
    • Views: 933
    04-21-2017, 08:11 PM Go to last post
  26. GFCI BREAKER RED TRIP LIGHT

    Started by CHARLIE VAN FLEET, 04-08-2017 05:21 PM
    breaker, gfci, light, red, trip
    • Replies: 12
    • Views: 2,523
    04-14-2017, 08:19 PM Go to last post
  27. NEC Bonding Article

    Started by Gunnar Alquist, 03-29-2017 10:46 AM
    bonding, disconnecting, equipment, means, service
    • Replies: 10
    • Views: 1,856
    04-02-2017, 07:47 PM Go to last post
  28. GFCI for sump pump or sewage ejectors

    Started by Don Hawley, 03-22-2017 06:30 AM
    • Replies: 7
    • Views: 2,165
    03-26-2017, 06:16 AM Go to last post
  29. Electrical Service Rating - HELP!

    Started by Tom Cissell, 11-02-2012 03:04 PM
    • Replies: 41
    • Views: 4,873
    03-19-2017, 06:04 PM Go to last post
  30. AKA sub-panel

    Started by Sam Morris, 03-09-2017 06:49 PM
    • Replies: 22
    • Views: 1,662
    03-13-2017, 09:18 PM Go to last post
  31. New GFCI

    Started by Jim Robinson, 05-28-2016 06:51 AM
    • Replies: 7
    • Views: 1,506
    03-07-2017, 09:49 AM Go to last post
  32. Breaker Securement

    Started by Raymond Wand, 10-11-2016 06:48 PM
    • Replies: 10
    • Views: 1,554
    03-06-2017, 11:27 PM Go to last post
  33. Panel manufacturer required

    Started by ROBERT YOUNG, 06-09-2016 09:52 AM
    • Replies: 2
    • Views: 1,139
    03-06-2017, 11:06 PM Go to last post
  34. Kentucky Home Inspectors and FPE panels

    Started by Scott Patterson, 12-04-2007 03:42 PM
    • Replies: 61
    • Views: 8,556
    03-02-2017, 11:07 AM Go to last post
  35. Use your camera as a step ladder.

    Started by Garry Sorrells, 02-22-2017 07:22 PM
    • Replies: 5
    • Views: 1,456
    02-23-2017, 09:44 AM Go to last post
  36. are wago connectors code compliant 2009 IRC

    Started by Jim Bunton, 02-20-2017 02:23 PM
    code, compliant, connectors, irc, wago
    • Replies: 2
    • Views: 767
    02-21-2017, 04:39 AM Go to last post
  37. six throws to shut off power ?

    Started by George Eberle, 02-13-2017 10:22 AM
    • Replies: 8
    • Views: 1,332
    02-16-2017, 05:33 PM Go to last post
  38. Hello everyone

    Started by George Eberle, 02-13-2017 10:00 AM
    george, post, power, shortly, thread
    • Replies: 0
    • Views: 380
    02-13-2017, 10:00 AM Go to last post
    • Replies: 5
    • Views: 817
    02-05-2017, 01:12 PM Go to last post
  39. electrical narrative required

    Started by ROBERT YOUNG, 02-01-2017 06:21 PM
    • Replies: 4
    • Views: 784
    02-02-2017, 04:32 AM Go to last post
  40. receptacle type

    Started by John Dirks Jr, 01-30-2017 06:14 AM
    • Replies: 3
    • Views: 581
    01-30-2017, 07:11 AM Go to last post
  41. is this improper grounding/bonding

    Started by Don Hawley, 01-26-2017 08:44 PM
    • Replies: 22
    • Views: 1,604
    01-27-2017, 07:43 PM Go to last post
    • Replies: 22
    • Views: 6,906
    01-26-2017, 06:33 PM Go to last post
  42. SEC splice

    Started by John Dirks Jr, 01-22-2017 06:20 PM
    • Replies: 43
    • Views: 1,462
    01-26-2017, 10:59 AM Go to last post
  43. wire size to compensate for voltage drop

    Started by Jack Feldmann, 12-22-2016 06:22 PM
    load, run, size, thought, wire
    • Replies: 12
    • Views: 1,315
    01-26-2017, 04:58 AM Go to last post
  44. Scorched/damaged grounding conductor

    Started by Robert Foster, 11-16-2016 04:58 PM
    • Replies: 2
    • Views: 1,346
    01-20-2017, 07:58 AM Go to last post
  45. EGC question

    Started by ROBERT YOUNG, 12-29-2016 12:13 PM
    acceptable, considered, egc, spray, styrofoam
    • Replies: 17
    • Views: 2,021
    01-11-2017, 04:51 PM Go to last post
  46. Improper multi-wire circuit??

    Started by Terry Beck, 12-13-2016 12:54 AM
    • Replies: 27
    • Views: 2,436
    12-17-2016, 10:17 AM Go to last post
  47. Wth is this ?!?

    Started by Aaron Scheuerer, 11-16-2016 04:23 PM
    • Replies: 11
    • Views: 1,897
    12-17-2016, 08:09 AM Go to last post
  48. Question exposed romex

    Started by Robert Gaspy, 11-17-2016 06:51 AM
    • Replies: 9
    • Views: 2,551
    11-30-2016, 09:15 PM Go to last post
  49. What panel is this!

    Started by adamjohn, 11-30-2016 02:26 AM
    • Replies: 1
    • Views: 1,163
    11-30-2016, 02:46 AM Go to last post
  50. Require help with a narrative.

    Started by ROBERT YOUNG, 11-13-2016 04:48 PM
    • Replies: 21
    • Views: 1,621
    11-16-2016, 11:11 PM Go to last post
  51. Require a narrative.

    Started by ROBERT YOUNG, 11-10-2016 04:37 AM
    • Replies: 15
    • Views: 2,002
    11-16-2016, 01:54 PM Go to last post
  52. service panel question

    Started by ROBERT YOUNG, 10-31-2016 04:08 PM
    • Replies: 10
    • Views: 1,583
    11-09-2016, 07:57 AM Go to last post
    • Replies: 5
    • Views: 905
    11-07-2016, 07:25 PM Go to last post
  53. Question Tester Tripping AFCI's

    Started by Michael Chambers, 11-03-2016 11:01 PM
    • Replies: 7
    • Views: 970
    11-04-2016, 10:27 PM Go to last post
  54. New issue with AFCI breakers tripping

    Started by Eric S, 09-01-2014 04:28 PM
    • Replies: 10
    • Views: 2,110
    11-03-2016, 10:33 PM Go to last post
  55. Neutral bus question.

    Started by ROBERT YOUNG, 10-22-2016 04:52 PM
    • Replies: 16
    • Views: 1,579
    10-31-2016, 07:45 AM Go to last post
  56. AKA Sub-Panel ground wire jumper

    Started by Sam Morris, 10-18-2016 06:20 PM
    • Replies: 12
    • Views: 1,498
    10-28-2016, 05:24 AM Go to last post
    • Replies: 1
    • Views: 711
    10-26-2016, 06:53 PM Go to last post
    • Replies: 7
    • Views: 1,646
    10-23-2016, 10:42 AM Go to last post
  57. Grounding electrode - DWV piping

    Started by Ken Amelin, 10-20-2016 07:50 AM
    • Replies: 29
    • Views: 1,597
    10-23-2016, 07:20 AM Go to last post
  58. Splices and Double tapped Service Drop

    Started by Lawrence Thomas, 10-04-2016 06:37 PM
    • Replies: 19
    • Views: 1,749
    10-21-2016, 05:44 PM Go to last post
  59. Require help to answer a question.

    Started by ROBERT YOUNG, 08-05-2016 10:09 PM
    • Replies: 16
    • Views: 1,937
    10-11-2016, 08:59 AM Go to last post
  60. GFCI circuit question

    Started by ROBERT YOUNG, 09-26-2016 10:22 AM
    • Replies: 49
    • Views: 2,217
    10-11-2016, 08:41 AM Go to last post
  61. 60's home with low voltage switching

    Started by Alton Darty, 10-04-2016 05:32 AM
    • Replies: 3
    • Views: 1,087
    10-11-2016, 08:04 AM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •