1. 04-16-2007
    Views:
    86,417

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. Can lighting added to Furnace branch circuit...

    Started by Jeff Weber, 03-26-2012 09:37 AM
    • Replies: 8
    • Views: 3,435
    03-26-2012, 06:46 PM Go to last post
  2. Breakers in incorrect location?

    Started by Marc M, 03-24-2012 11:09 PM
    • Replies: 13
    • Views: 2,138
    03-25-2012, 07:27 PM Go to last post
  3. Main breaker dissconect

    Started by Martin Holtmeyer, 03-22-2012 03:18 PM
    • Replies: 13
    • Views: 1,827
    03-23-2012, 08:26 PM Go to last post
  4. First time for this

    Started by Richard Roshak, 03-23-2012 01:47 PM
    • Replies: 3
    • Views: 1,171
    03-23-2012, 04:51 PM Go to last post
  5. Very old Federal panel

    Started by Gene South, 03-23-2012 07:11 AM
    • Replies: 4
    • Views: 1,095
    03-23-2012, 04:03 PM Go to last post
  6. commercial disconect

    Started by Russell Melville, 03-11-2012 05:18 PM
    • Replies: 37
    • Views: 3,351
    03-23-2012, 08:35 AM Go to last post
  7. What is this old outlet ? See photo

    Started by Gene South, 03-22-2012 05:55 PM
    • Replies: 7
    • Views: 2,128
    03-23-2012, 07:27 AM Go to last post
  8. Gap Between Deadfront Cover and Breakers

    Started by Nick Ostrowski, 03-22-2012 04:07 AM
    • Replies: 10
    • Views: 4,254
    03-22-2012, 04:54 PM Go to last post
  9. Just wondering

    Started by Edward Rodriguez, 03-18-2012 07:19 PM
    • Replies: 17
    • Views: 2,525
    03-22-2012, 11:25 AM Go to last post
  10. Torn in Sheatrhing on Service Cable

    Started by Nick Ostrowski, 03-21-2012 09:28 AM
    • Replies: 7
    • Views: 1,489
    03-21-2012, 05:12 PM Go to last post
  11. Good sub panel explanation link

    Started by Tim Barnett, 03-12-2012 06:53 PM
    • Replies: 15
    • Views: 5,291
    03-19-2012, 01:48 PM Go to last post
  12. Service Box & Wire

    Started by Jeff Zehnder, 03-11-2012 04:10 PM
    • Replies: 26
    • Views: 3,105
    03-16-2012, 01:33 PM Go to last post
  13. Main or sub

    Started by cglochau, 03-12-2012 07:44 PM
    • Replies: 5
    • Views: 1,183
    03-16-2012, 10:12 AM Go to last post
  14. Special - Not for General Use

    Started by Don Martin, 03-15-2012 12:04 PM
    • Replies: 8
    • Views: 1,747
    03-16-2012, 06:08 AM Go to last post
  15. trumbull panel

    Started by Russell Melville, 03-13-2012 06:21 PM
    • Replies: 3
    • Views: 2,754
    03-14-2012, 09:01 AM Go to last post
  16. Entrance exterior light required?

    Started by John Arnold, 01-28-2012 05:02 PM
    • Replies: 8
    • Views: 5,775
    03-14-2012, 07:58 AM Go to last post
  17. Shower light fixture

    Started by Richard Roshak, 03-10-2012 03:06 PM
    • Replies: 11
    • Views: 3,601
    03-11-2012, 11:01 AM Go to last post
  18. Is this Aluminum wire?

    Started by Robert Foster, 03-09-2012 05:44 AM
    • Replies: 8
    • Views: 1,671
    03-09-2012, 03:53 PM Go to last post
  19. Altered distribution panel

    Started by mathew stouffer, 02-16-2012 07:30 AM
    • Replies: 36
    • Views: 3,556
    03-07-2012, 09:37 AM Go to last post
  20. disposal/DW shared neutral

    Started by Matt Fellman, 02-29-2012 06:29 PM
    • Replies: 5
    • Views: 1,488
    03-06-2012, 05:08 PM Go to last post
  21. old fuse panel

    Started by Eric Smith, 03-05-2012 08:31 PM
    • Replies: 4
    • Views: 2,120
    03-06-2012, 05:30 AM Go to last post
  22. No Main Panel Shut-off in home

    Started by Jeremy Meek, 03-05-2012 11:45 AM
    • Replies: 0
    • Views: 1,182
    03-05-2012, 11:45 AM Go to last post
  23. See what happened to me today..

    Started by Marc M, 01-13-2012 08:02 PM
    • Replies: 31
    • Views: 3,091
    03-02-2012, 10:04 AM Go to last post
  24. leviton illustrated guide for 2008 nec

    Started by CHARLIE VAN FLEET, 11-09-2011 02:06 PM
    • Replies: 4
    • Views: 2,887
    03-02-2012, 06:42 AM Go to last post
  25. Kitchen Island receptacle requirements

    Started by mathew stouffer, 02-28-2012 06:20 PM
    • Replies: 25
    • Views: 34,521
    03-02-2012, 01:51 AM Go to last post
  26. Breaker Labling

    Started by Don Martin, 02-22-2012 06:33 AM
    • Replies: 14
    • Views: 2,600
    02-26-2012, 07:49 AM Go to last post
  27. Old electrical Panels

    Started by Eric Farjoo, 02-20-2012 11:04 PM
    • Replies: 25
    • Views: 6,315
    02-25-2012, 04:41 AM Go to last post
  28. Testing Ground Fault Breakers

    Started by Jon Errickson, 02-20-2012 12:16 PM
    • Replies: 5
    • Views: 1,651
    02-22-2012, 08:07 PM Go to last post
  29. Junction Box

    Started by Tom Rees, 02-21-2012 04:21 PM
    • Replies: 9
    • Views: 2,174
    02-22-2012, 04:03 PM Go to last post
  30. Deadfront Terminology Question

    Started by Michael Thomas, 02-20-2012 07:48 AM
    • Replies: 9
    • Views: 7,808
    02-22-2012, 10:14 AM Go to last post
  31. Question 2011 code... replacement outlets

    Started by Bob Sisson, 01-30-2012 06:49 AM
    • Replies: 39
    • Views: 4,480
    02-21-2012, 01:58 PM Go to last post
  32. Conductor Radius

    Started by Marc M, 02-13-2012 10:19 PM
    • Replies: 23
    • Views: 5,662
    02-21-2012, 08:44 AM Go to last post
  33. How about some 'copper tubing' fuses...

    Started by Mark Brown, 11-11-2011 11:43 AM
    • Replies: 20
    • Views: 3,891
    02-20-2012, 07:00 PM Go to last post
  34. Service Entrance @ Patio Cover

    Started by Mike Birenbaum, 02-16-2012 07:49 AM
    • Replies: 4
    • Views: 2,083
    02-16-2012, 02:29 PM Go to last post
  35. Random Light Dimming

    Started by Rod Butler, 01-27-2012 05:59 AM
    • Replies: 12
    • Views: 12,003
    02-16-2012, 10:50 AM Go to last post
  36. Exposed romex

    Started by Jody Humbert, 02-14-2012 12:05 PM
    • Replies: 13
    • Views: 30,581
    02-16-2012, 05:39 AM Go to last post
  37. Missing knock out plugs

    Started by william siegel, 02-14-2012 02:28 PM
    • Replies: 3
    • Views: 1,717
    02-15-2012, 11:37 AM Go to last post
  38. Green Wiring

    Started by Ron Murphy, 02-13-2012 04:25 PM
    • Replies: 14
    • Views: 1,793
    02-15-2012, 08:41 AM Go to last post
  39. Home Owner Double Tap Problems

    Started by John Thompson, 07-29-2010 02:41 PM
    • Replies: 62
    • Views: 17,776
    02-14-2012, 10:34 PM Go to last post
  40. Can Light IC or No IC???

    Started by Bill Anglin, 02-10-2012 08:22 PM
    • Replies: 12
    • Views: 5,222
    02-13-2012, 07:19 PM Go to last post
  41. Fixed Breaker Arm

    Started by Nick Ostrowski, 02-09-2012 03:40 PM
    • Replies: 17
    • Views: 2,865
    02-10-2012, 07:57 PM Go to last post
    • Replies: 3
    • Views: 1,570
    02-06-2012, 07:18 PM Go to last post
  42. 20 Amp AFCI overfusing

    Started by John Arnold, 01-23-2012 01:56 PM
    • Replies: 10
    • Views: 2,924
    02-06-2012, 04:04 AM Go to last post
  43. Super Watt Sucker

    Started by Rick Bunzel, 01-30-2012 08:37 AM
    • Replies: 12
    • Views: 2,132
    02-03-2012, 10:37 AM Go to last post
  44. Outlet along countertop

    Started by mathew stouffer, 01-31-2012 06:02 AM
    • Replies: 6
    • Views: 1,502
    02-01-2012, 06:32 PM Go to last post
  45. light fixture in kitchen

    Started by sidney alstad, 01-30-2012 12:41 PM
    • Replies: 8
    • Views: 1,973
    01-31-2012, 11:16 AM Go to last post
  46. electrical bonding to earth with Post tension

    Started by nick alati, 01-26-2012 04:36 AM
    • Replies: 9
    • Views: 3,448
    01-27-2012, 07:56 AM Go to last post
  47. determining panel amperage

    Started by Kristi Silber, 01-18-2012 02:21 PM
    • Replies: 28
    • Views: 11,099
    01-23-2012, 04:04 PM Go to last post
  48. Outlets on staircase landings

    Started by mathew stouffer, 01-18-2012 06:27 PM
    • Replies: 33
    • Views: 9,578
    01-23-2012, 06:46 AM Go to last post
    • Replies: 15
    • Views: 9,242
    01-19-2012, 05:46 AM Go to last post
  49. branch circuit in detached shop

    Started by John Kogel, 01-15-2012 05:56 PM
    • Replies: 6
    • Views: 2,287
    01-16-2012, 08:45 PM Go to last post
  50. GE Powermark Gold Bonding concern

    Started by Adam Proud, 01-14-2012 09:23 PM
    • Replies: 24
    • Views: 9,807
    01-16-2012, 02:48 PM Go to last post
  51. Timer Switch as Pool Disconnect

    Started by Andy G, 12-21-2011 03:42 AM
    • Replies: 28
    • Views: 5,061
    01-14-2012, 11:39 AM Go to last post
  52. couple of questions please...

    Started by TheCarpEnters, 01-09-2012 07:13 PM
    • Replies: 14
    • Views: 2,114
    01-12-2012, 02:20 AM Go to last post
  53. Buzzing AFCI

    Started by Drew McGee, 12-16-2007 06:42 PM
    • Replies: 31
    • Views: 9,462
    01-11-2012, 07:30 PM Go to last post
  54. What would you say?

    Started by Richard Roshak, 01-09-2012 03:14 PM
    • Replies: 9
    • Views: 1,460
    01-10-2012, 03:57 PM Go to last post
  55. What is this for?

    Started by Matt Fellman, 01-09-2012 04:44 PM
    • Replies: 7
    • Views: 2,622
    01-10-2012, 09:42 AM Go to last post
  56. Question about service change

    Started by Chris DiMarco, 12-31-2011 03:03 PM
    • Replies: 57
    • Views: 3,054
    01-06-2012, 03:13 AM Go to last post
  57. AFCI warm and buzzing

    Started by stanley frost, 01-02-2012 01:02 PM
    • Replies: 3
    • Views: 4,217
    01-03-2012, 11:16 AM Go to last post
  58. service mast - this can't be right?!

    Started by Kristi Silber, 11-17-2011 08:31 PM
    • Replies: 47
    • Views: 5,939
    01-03-2012, 09:47 AM Go to last post
  59. Grounding at water heater

    Started by Bill Anglin, 12-29-2011 09:56 AM
    • Replies: 18
    • Views: 4,860
    01-02-2012, 09:02 AM Go to last post
  60. Wierd Outlet

    Started by John Thompson, 12-06-2011 08:10 PM
    • Replies: 22
    • Views: 2,827
    12-25-2011, 08:02 AM Go to last post
  61. Direct Wired Range

    Started by Michael Chambers, 12-17-2011 12:04 PM
    • Replies: 41
    • Views: 14,342
    12-21-2011, 07:49 PM Go to last post
  62. Those pesky fence installers

    Started by Jack Feldmann, 03-17-2011 01:06 PM
    • Replies: 26
    • Views: 4,414
    12-20-2011, 05:23 PM Go to last post
  63. Question RE: Grounding

    Started by Marc M, 12-19-2011 11:14 PM
    • Replies: 6
    • Views: 1,494
    12-20-2011, 02:13 PM Go to last post
  64. 2 panels

    Started by Eric Smith, 12-14-2011 12:28 PM
    • Replies: 13
    • Views: 3,172
    12-19-2011, 04:12 PM Go to last post
  65. three wire to storage shed

    Started by Eric Smith, 12-11-2011 06:41 AM
    • Replies: 6
    • Views: 2,846
    12-15-2011, 03:05 PM Go to last post
  66. Coax plugged in???

    Started by Bill Anglin, 12-10-2011 04:52 PM
    • Replies: 9
    • Views: 2,288
    12-14-2011, 07:25 AM Go to last post
  67. Tripless circuit breaker?

    Started by JB Thompson, 09-23-2011 04:47 PM
    • Replies: 13
    • Views: 2,669
    12-12-2011, 06:04 PM Go to last post
  68. Hot Tub Disconnect, jumper

    Started by mathew stouffer, 12-09-2011 12:41 PM
    • Replies: 6
    • Views: 1,598
    12-10-2011, 02:59 PM Go to last post
  69. Double Pole Breaker

    Started by Wade Johnson, 12-07-2011 08:26 AM
    • Replies: 2
    • Views: 1,804
    12-08-2011, 11:00 AM Go to last post
  70. 4 wire feeders for outbuildings

    Started by Don Hester, 12-07-2011 10:25 AM
    • Replies: 8
    • Views: 3,072
    12-08-2011, 01:39 AM Go to last post
  71. ISLAND OUTLET NON GFCI

    Started by CHARLIE VAN FLEET, 11-25-2011 06:08 PM
    2 Pages
    1 2
    • Replies: 111
    • Views: 10,195
    12-06-2011, 11:28 PM Go to last post
  72. Conduit nipple / UF on outside recep.

    Started by Andy G, 12-05-2011 03:49 AM
    • Replies: 2
    • Views: 1,218
    12-06-2011, 08:00 AM Go to last post
  73. Federal Pacific panel/stob-lak breakers

    Started by Raghav Singh, 12-01-2011 07:45 PM
    • Replies: 32
    • Views: 7,832
    12-06-2011, 06:15 AM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •