1. 04-16-2007
    Views:
    116,557

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. AFCI warm and buzzing

    Started by stanley frost, 01-02-2012 02:02 PM
    • Replies: 3
    • Views: 5,217
    01-03-2012, 12:16 PM Go to last post
  2. service mast - this can't be right?!

    Started by Kristi Silber, 11-17-2011 09:31 PM
    • Replies: 47
    • Views: 6,957
    01-03-2012, 10:47 AM Go to last post
  3. Grounding at water heater

    Started by Bill Anglin, 12-29-2011 10:56 AM
    • Replies: 18
    • Views: 5,817
    01-02-2012, 10:02 AM Go to last post
  4. Wierd Outlet

    Started by John Thompson, 12-06-2011 09:10 PM
    • Replies: 22
    • Views: 3,583
    12-25-2011, 09:02 AM Go to last post
  5. Direct Wired Range

    Started by Michael Chambers, 12-17-2011 01:04 PM
    • Replies: 41
    • Views: 18,330
    12-21-2011, 08:49 PM Go to last post
  6. Those pesky fence installers

    Started by Jack Feldmann, 03-17-2011 01:06 PM
    • Replies: 26
    • Views: 5,479
    12-20-2011, 06:23 PM Go to last post
  7. Question RE: Grounding

    Started by Marc M, 12-20-2011 12:14 AM
    • Replies: 6
    • Views: 2,025
    12-20-2011, 03:13 PM Go to last post
  8. 2 panels

    Started by Eric Smith, 12-14-2011 01:28 PM
    • Replies: 13
    • Views: 4,153
    12-19-2011, 05:12 PM Go to last post
  9. three wire to storage shed

    Started by Eric Smith, 12-11-2011 07:41 AM
    • Replies: 6
    • Views: 3,457
    12-15-2011, 04:05 PM Go to last post
  10. Coax plugged in???

    Started by Bill Anglin, 12-10-2011 05:52 PM
    • Replies: 9
    • Views: 2,798
    12-14-2011, 08:25 AM Go to last post
  11. Tripless circuit breaker?

    Started by JB Thompson, 09-23-2011 04:47 PM
    • Replies: 13
    • Views: 3,265
    12-12-2011, 07:04 PM Go to last post
  12. Hot Tub Disconnect, jumper

    Started by mathew stouffer, 12-09-2011 01:41 PM
    • Replies: 6
    • Views: 2,033
    12-10-2011, 03:59 PM Go to last post
  13. Double Pole Breaker

    Started by Wade Johnson, 12-07-2011 09:26 AM
    • Replies: 2
    • Views: 2,454
    12-08-2011, 12:00 PM Go to last post
  14. 4 wire feeders for outbuildings

    Started by Don Hester, 12-07-2011 11:25 AM
    • Replies: 8
    • Views: 3,819
    12-08-2011, 02:39 AM Go to last post
  15. ISLAND OUTLET NON GFCI

    Started by CHARLIE VAN FLEET, 11-25-2011 07:08 PM
    2 Pages
    1 2
    • Replies: 111
    • Views: 12,789
    12-07-2011, 12:28 AM Go to last post
  16. Conduit nipple / UF on outside recep.

    Started by Andy G, 12-05-2011 04:49 AM
    • Replies: 2
    • Views: 1,783
    12-06-2011, 09:00 AM Go to last post
  17. Federal Pacific panel/stob-lak breakers

    Started by Raghav Singh, 12-01-2011 08:45 PM
    • Replies: 32
    • Views: 9,428
    12-06-2011, 07:15 AM Go to last post
  18. small green wire

    Started by Eric Smith, 11-26-2011 02:09 PM
    • Replies: 10
    • Views: 2,350
    12-03-2011, 04:02 PM Go to last post
    • Replies: 1
    • Views: 1,415
    12-02-2011, 03:50 PM Go to last post
  19. Disconnect question

    Started by Marc M, 12-01-2011 08:54 PM
    • Replies: 8
    • Views: 2,444
    12-02-2011, 09:09 AM Go to last post
  20. Electrical panel question

    Started by Charlie Crouthamel, 11-28-2011 06:03 PM
    • Replies: 8
    • Views: 2,222
    11-29-2011, 03:48 PM Go to last post
  21. Bundling of Romex (NM cable)

    Started by Roger Frazee, 11-21-2011 10:43 PM
    • Replies: 16
    • Views: 24,687
    11-24-2011, 06:25 PM Go to last post
  22. How not to ground a generator

    Started by Raymond Wand, 11-22-2011 01:24 PM
    • Replies: 2
    • Views: 1,697
    11-23-2011, 06:47 PM Go to last post
  23. GFI fails after turning off circuit power

    Started by Matt Fellman, 11-20-2011 09:52 PM
    • Replies: 9
    • Views: 2,925
    11-22-2011, 08:05 PM Go to last post
  24. Receptacle near a gravity wall furnace

    Started by Edward Rodriguez, 11-21-2011 08:05 AM
    • Replies: 5
    • Views: 2,240
    11-22-2011, 08:41 AM Go to last post
  25. Service Panel in bathroom closet

    Started by Rick Bunzel, 11-21-2011 06:05 PM
    • Replies: 6
    • Views: 5,776
    11-22-2011, 06:18 AM Go to last post
  26. Edison Fused Dryer

    Started by Don Martin, 11-20-2011 12:55 PM
    • Replies: 1
    • Views: 1,550
    11-21-2011, 08:21 AM Go to last post
  27. Service Entrance Masts to Duplex

    Started by Steve Myers, 11-14-2011 01:23 PM
    • Replies: 15
    • Views: 2,612
    11-19-2011, 10:08 AM Go to last post
  28. #12 AWG for Neutral at Service

    Started by Mark Brown, 11-07-2011 10:55 AM
    • Replies: 63
    • Views: 5,097
    11-18-2011, 08:41 AM Go to last post
  29. Max Number of GFI on one Circuit

    Started by Marc M, 11-12-2011 01:44 AM
    • Replies: 15
    • Views: 29,495
    11-14-2011, 05:55 PM Go to last post
  30. Zap

    Started by Rick Cantrell, 10-31-2011 02:21 PM
    • Replies: 18
    • Views: 2,876
    11-14-2011, 10:14 AM Go to last post
    • Replies: 4
    • Views: 4,517
    11-11-2011, 07:12 PM Go to last post
  31. Work of Art?

    Started by Nick Ostrowski, 11-07-2011 05:09 PM
    • Replies: 10
    • Views: 2,422
    11-09-2011, 08:36 PM Go to last post
  32. Extension Cord in the Attic

    Started by Chuck Swan, 11-05-2011 09:20 PM
    • Replies: 18
    • Views: 12,028
    11-09-2011, 08:41 AM Go to last post
  33. Name this cord set

    Started by Robert Mattison, 09-14-2009 02:37 PM
    • Replies: 16
    • Views: 3,174
    11-08-2011, 06:40 PM Go to last post
  34. some models of ideal suretest require...

    Started by BARRY ADAIR, 11-06-2011 03:17 AM
    • Replies: 4
    • Views: 1,803
    11-07-2011, 10:29 PM Go to last post
  35. OLD POST HELP NEEDED

    Started by CHARLIE VAN FLEET, 11-07-2011 03:46 PM
    • Replies: 3
    • Views: 1,346
    11-07-2011, 04:43 PM Go to last post
  36. SEC Clearance over roof

    Started by Steve C., 11-03-2011 09:23 PM
    • Replies: 9
    • Views: 3,164
    11-05-2011, 04:57 AM Go to last post
    • Replies: 39
    • Views: 16,363
    11-05-2011, 04:04 AM Go to last post
  37. correct wire attachment to breaker?

    Started by Andy Shapley, 11-03-2011 12:09 PM
    • Replies: 7
    • Views: 2,453
    11-04-2011, 08:49 AM Go to last post
  38. how common is aluminum NM?

    Started by Kristi Silber, 10-31-2011 07:30 PM
    • Replies: 9
    • Views: 2,537
    11-02-2011, 04:10 PM Go to last post
  39. no voltage between wires...

    Started by Joe Pinto, 10-27-2011 03:36 PM
    • Replies: 33
    • Views: 8,736
    11-01-2011, 05:44 PM Go to last post
  40. Switches/Outlets Faceplates

    Started by brianmiller, 10-31-2011 06:53 PM
    • Replies: 11
    • Views: 3,720
    11-01-2011, 12:27 PM Go to last post
    • Replies: 3
    • Views: 2,393
    10-31-2011, 12:34 AM Go to last post
  41. Height of main disconnect

    Started by Ken Amelin, 10-23-2011 05:20 AM
    • Replies: 13
    • Views: 14,926
    10-28-2011, 08:42 PM Go to last post
  42. Conduit and box covered with stucco

    Started by mathew stouffer, 06-07-2011 06:56 PM
    • Replies: 38
    • Views: 11,922
    10-27-2011, 04:59 PM Go to last post
  43. I love Mondays

    Started by mathew stouffer, 10-25-2011 06:30 AM
    • Replies: 2
    • Views: 1,444
    10-27-2011, 01:03 PM Go to last post
  44. Can you read this Chinese label for me?

    Started by John Kogel, 10-23-2011 09:46 AM
    • Replies: 3
    • Views: 2,092
    10-24-2011, 08:59 PM Go to last post
  45. splice

    Started by Ron Bishop, 10-22-2011 07:57 AM
    • Replies: 5
    • Views: 2,079
    10-24-2011, 08:56 PM Go to last post
  46. Exposed Contacts

    Started by Raghav Singh, 10-23-2011 03:40 AM
    • Replies: 11
    • Views: 2,501
    10-24-2011, 07:39 PM Go to last post
    • Replies: 8
    • Views: 2,438
    10-21-2011, 03:53 PM Go to last post
  47. Breaker Identification

    Started by Andrew Kolar, 10-21-2011 05:02 AM
    • Replies: 2
    • Views: 1,961
    10-21-2011, 08:28 AM Go to last post
  48. Baffling switched receptacles question.

    Started by John Kogel, 10-13-2011 07:14 PM
    • Replies: 29
    • Views: 3,858
    10-19-2011, 07:11 PM Go to last post
  49. Faulty GFI

    Started by cglochau, 10-18-2011 01:30 PM
    • Replies: 2
    • Views: 1,454
    10-18-2011, 03:51 PM Go to last post
  50. Great stuff foam

    Started by Rick Cantrell, 09-19-2008 05:00 PM
    • Replies: 31
    • Views: 28,953
    10-17-2011, 05:34 PM Go to last post
  51. Stray Voltage or Fish Story?

    Started by Gunnar Alquist, 10-14-2011 07:08 AM
    • Replies: 5
    • Views: 2,257
    10-15-2011, 12:56 PM Go to last post
  52. Dedicated 20A Kitchen circuit

    Started by Stuart Brooks, 10-08-2011 11:31 AM
    2 Pages
    1 2
    • Replies: 76
    • Views: 12,367
    10-14-2011, 07:00 AM Go to last post
    • Replies: 8
    • Views: 2,321
    10-12-2011, 04:58 PM Go to last post
  53. First Receptacle

    Started by Jim Robinson, 10-08-2011 01:22 PM
    • Replies: 17
    • Views: 8,037
    10-12-2011, 01:45 PM Go to last post
  54. So, that's not a disconnect?

    Started by Marc Morin, 10-10-2011 03:07 PM
    • Replies: 7
    • Views: 2,406
    10-11-2011, 06:41 PM Go to last post
  55. Sink Hole Inspections

    Started by Alan Trauger, 10-11-2011 12:58 PM
    • Replies: 0
    • Views: 1,228
    10-11-2011, 12:58 PM Go to last post
  56. 12-2 with ground for multi wire

    Started by Benjamin Thompson, 09-23-2011 06:25 PM
    2 Pages
    1 2
    • Replies: 86
    • Views: 9,846
    10-11-2011, 04:21 AM Go to last post
    • Replies: 31
    • Views: 22,542
    10-10-2011, 04:44 PM Go to last post
  57. G.F.C.I. on a 2 wire system?

    Started by James Norman, 09-26-2011 12:47 PM
    • Replies: 29
    • Views: 25,205
    10-04-2011, 06:57 AM Go to last post
  58. Another painted panel

    Started by John Arnold, 09-30-2011 06:30 PM
    • Replies: 5
    • Views: 2,220
    10-03-2011, 09:37 AM Go to last post
  59. Simson HUCQ

    Started by Doug Lessa, 09-29-2011 09:09 PM
    • Replies: 3
    • Views: 2,304
    09-30-2011, 08:28 AM Go to last post
  60. Great for training panel

    Started by Rick Vernon, 09-20-2011 06:28 AM
    • Replies: 18
    • Views: 3,285
    09-30-2011, 04:46 AM Go to last post
  61. Pipe bonding

    Started by Ken Amelin, 09-25-2011 04:29 AM
    • Replies: 19
    • Views: 3,441
    09-28-2011, 03:36 PM Go to last post
  62. Shinners

    Started by Vern Heiler, 09-21-2011 04:58 PM
    • Replies: 12
    • Views: 2,554
    09-23-2011, 03:55 PM Go to last post
  63. puzzler

    Started by brianmiller, 09-21-2011 07:46 AM
    • Replies: 4
    • Views: 1,564
    09-21-2011, 02:59 PM Go to last post
  64. Service and steel garbage chute

    Started by Markus Keller, 09-20-2011 07:20 PM
    • Replies: 3
    • Views: 1,701
    09-21-2011, 08:09 AM Go to last post
  65. Electric Dryer and Range Bonding of Neutral

    Started by Steve Miller, 09-18-2011 12:38 PM
    • Replies: 2
    • Views: 1,840
    09-20-2011, 02:27 PM Go to last post
  66. Forgot the name of this

    Started by Marc M, 09-18-2011 10:18 PM
    • Replies: 4
    • Views: 2,656
    09-20-2011, 02:18 PM Go to last post
  67. spliced feeder

    Started by jim baird, 09-19-2011 07:25 AM
    • Replies: 2
    • Views: 1,510
    09-19-2011, 08:54 AM Go to last post
  68. Service Connection

    Started by Don Martin, 09-15-2011 05:59 PM
    • Replies: 9
    • Views: 3,087
    09-19-2011, 06:10 AM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •