1. 04-16-2007
    Views:
    89,063

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. FPE panel in good shape

    Started by John Kogel, 06-15-2011 08:56 PM
    • Replies: 25
    • Views: 3,204
    06-18-2011, 04:52 PM Go to last post
  2. "Scorched" breaker handles

    Started by Michael Thomas, 06-13-2011 07:24 PM
    • Replies: 9
    • Views: 2,420
    06-14-2011, 07:23 PM Go to last post
  3. Seeing is believing

    Started by Robert Foster, 06-09-2011 06:38 PM
    • Replies: 8
    • Views: 1,890
    06-14-2011, 06:04 PM Go to last post
  4. 12 G aluminum / copper wire nut

    Started by Jon mackay, 06-13-2011 10:46 AM
    • Replies: 5
    • Views: 4,294
    06-14-2011, 09:57 AM Go to last post
  5. Double breaker position in GE panel

    Started by John Kogel, 06-08-2011 09:48 PM
    • Replies: 16
    • Views: 4,551
    06-10-2011, 08:39 PM Go to last post
  6. What's this component called?

    Started by Marc M, 06-09-2011 09:09 PM
    • Replies: 13
    • Views: 2,615
    06-10-2011, 07:07 PM Go to last post
  7. Interconnected smoke alarms

    Started by Marc M, 06-08-2011 07:59 PM
    • Replies: 2
    • Views: 1,592
    06-09-2011, 07:45 AM Go to last post
  8. Surge arrestor

    Started by mathew stouffer, 05-30-2011 11:08 AM
    • Replies: 5
    • Views: 2,392
    06-07-2011, 06:07 PM Go to last post
  9. Light/fan inside bathroom shower

    Started by Thomas Thayer, 06-05-2011 04:35 PM
    • Replies: 17
    • Views: 35,099
    06-07-2011, 02:22 PM Go to last post
  10. FPE panel

    Started by Jon Errickson, 05-28-2011 10:11 PM
    • Replies: 31
    • Views: 4,568
    06-06-2011, 11:13 AM Go to last post
  11. How many wires per nut

    Started by Jon mackay, 06-06-2011 09:11 AM
    • Replies: 3
    • Views: 3,301
    06-06-2011, 10:56 AM Go to last post
  12. Hard wired clothes dryer

    Started by Jon mackay, 06-03-2011 03:34 PM
    • Replies: 4
    • Views: 5,554
    06-04-2011, 08:55 PM Go to last post
    • Replies: 15
    • Views: 2,291
    06-04-2011, 03:36 AM Go to last post
  13. 312.8 Changes

    Started by Jim Port, 06-02-2011 08:39 AM
    • Replies: 3
    • Views: 4,956
    06-03-2011, 09:05 AM Go to last post
  14. strange panel

    Started by Russell Melville, 06-02-2011 06:26 PM
    • Replies: 2
    • Views: 1,249
    06-03-2011, 05:47 AM Go to last post
    • Replies: 32
    • Views: 21,400
    06-02-2011, 10:54 AM Go to last post
  15. Double tapped lugs in service

    Started by mathew stouffer, 05-31-2011 01:33 PM
    • Replies: 10
    • Views: 3,585
    06-01-2011, 06:36 PM Go to last post
  16. Surge arrestor

    Started by mathew stouffer, 05-30-2011 11:29 AM
    • Replies: 2
    • Views: 1,740
    05-31-2011, 12:56 AM Go to last post
  17. Readily Accessible-question

    Started by Marc M, 05-28-2011 11:19 PM
    • Replies: 5
    • Views: 3,638
    05-29-2011, 08:39 PM Go to last post
  18. sec protection?

    Started by John Arnold, 05-27-2011 01:53 PM
    • Replies: 6
    • Views: 1,617
    05-28-2011, 05:59 AM Go to last post
  19. Service meter

    Started by JIM MURPHY, 05-26-2011 02:12 PM
    • Replies: 2
    • Views: 1,397
    05-27-2011, 11:24 AM Go to last post
  20. Mismatched Service Cable Sizes

    Started by Nick Ostrowski, 05-24-2011 06:36 AM
    • Replies: 18
    • Views: 3,295
    05-26-2011, 05:14 AM Go to last post
    • Replies: 3
    • Views: 1,545
    05-25-2011, 09:09 PM Go to last post
    • Replies: 5
    • Views: 2,360
    05-25-2011, 03:59 PM Go to last post
    • Replies: 6
    • Views: 1,641
    05-25-2011, 07:35 AM Go to last post
    • Replies: 4
    • Views: 1,455
    05-24-2011, 07:22 PM Go to last post
  21. Refrigerator on GFCI circuit

    Started by Phillip Stojanik, 07-28-2007 02:04 PM
    • Replies: 32
    • Views: 35,073
    05-23-2011, 08:17 PM Go to last post
    • Replies: 3
    • Views: 2,296
    05-23-2011, 07:23 AM Go to last post
  22. Main feeder looped around branch circuits

    Started by Don Halligan, 05-20-2011 07:59 PM
    • Replies: 3
    • Views: 1,793
    05-21-2011, 11:21 AM Go to last post
  23. Branch Panel Question

    Started by Chris Skoczylas, 05-19-2011 04:00 PM
    • Replies: 3
    • Views: 1,289
    05-19-2011, 06:11 PM Go to last post
  24. New Item on panel Never seen before

    Started by Thomas Tadd, 05-17-2011 07:39 PM
    • Replies: 8
    • Views: 1,692
    05-19-2011, 06:10 PM Go to last post
  25. Cutler Hammer Breakers

    Started by Marc Morin, 11-10-2010 08:07 PM
    • Replies: 5
    • Views: 5,439
    05-19-2011, 10:01 AM Go to last post
  26. Rats nest in panel

    Started by mathew stouffer, 05-12-2011 06:53 AM
    • Replies: 19
    • Views: 4,696
    05-18-2011, 07:09 PM Go to last post
  27. Is this 100 amp or 200 amp service?

    Started by Wayne Turley, 02-01-2009 01:26 AM
    • Replies: 18
    • Views: 81,352
    05-17-2011, 08:18 PM Go to last post
  28. Condo mechanical room

    Started by Peter Louis, 05-16-2011 09:35 PM
    • Replies: 4
    • Views: 3,039
    05-17-2011, 06:03 PM Go to last post
  29. 100 amp service

    Started by Len Couey, 05-12-2011 02:40 PM
    • Replies: 11
    • Views: 6,543
    05-17-2011, 03:46 AM Go to last post
  30. No power & looking for an answer why

    Started by Bill Wieczorek, 05-16-2011 07:47 AM
    • Replies: 6
    • Views: 2,034
    05-16-2011, 06:23 PM Go to last post
  31. Panel behind refrigerator

    Started by wayne soper, 05-16-2011 02:18 PM
    • Replies: 4
    • Views: 1,844
    05-16-2011, 04:28 PM Go to last post
  32. 208V 3-ph - no neutral

    Started by Ken Amelin, 06-16-2010 06:19 AM
    • Replies: 39
    • Views: 12,056
    05-15-2011, 11:13 AM Go to last post
  33. GFCI circuit servicing two or more rooms

    Started by Bill Anglin, 05-12-2011 08:51 PM
    • Replies: 13
    • Views: 8,614
    05-14-2011, 12:52 PM Go to last post
  34. Breaker

    Started by Tom Rees, 05-11-2011 03:57 PM
    • Replies: 10
    • Views: 1,741
    05-12-2011, 05:15 AM Go to last post
  35. what a mess

    Started by John Arnold, 05-11-2011 01:35 PM
    • Replies: 3
    • Views: 1,310
    05-11-2011, 07:12 PM Go to last post
  36. 220 outlet in bedroom

    Started by mathew stouffer, 05-11-2011 06:58 AM
    • Replies: 6
    • Views: 1,547
    05-11-2011, 12:22 PM Go to last post
  37. I don't get it....

    Started by Matt Fellman, 05-02-2011 04:50 PM
    • Replies: 10
    • Views: 2,112
    05-10-2011, 05:13 PM Go to last post
  38. Electrical panel connections

    Started by Don Horn, 02-25-2011 09:55 AM
    • Replies: 9
    • Views: 1,921
    05-10-2011, 09:48 AM Go to last post
  39. Using Dimmers with CFLs

    Started by craig laMere, 05-09-2011 11:27 AM
    • Replies: 0
    • Views: 1,106
    05-09-2011, 11:27 AM Go to last post
  40. Metal pool filters-bonding.

    Started by Marc M, 04-27-2011 11:15 AM
    • Replies: 33
    • Views: 5,166
    05-09-2011, 04:07 AM Go to last post
  41. Main Electrical "Maximum" Feed Length

    Started by Rich Sumen, 05-04-2011 12:43 PM
    • Replies: 14
    • Views: 14,967
    05-08-2011, 09:54 AM Go to last post
  42. Cool House Electrical Panel Directory

    Started by Robert Mattison, 05-01-2011 12:41 PM
    • Replies: 21
    • Views: 4,831
    05-07-2011, 05:53 AM Go to last post
  43. Overhead Wiring

    Started by Stephen G Sheldon, 04-30-2011 02:33 PM
    • Replies: 7
    • Views: 2,444
    05-06-2011, 07:28 PM Go to last post
  44. Wiring on attic floor

    Started by Jon mackay, 09-11-2010 06:09 AM
    • Replies: 51
    • Views: 16,667
    05-04-2011, 12:25 PM Go to last post
  45. Remote panel in crawlspace

    Started by Marc M, 05-03-2011 09:55 PM
    • Replies: 7
    • Views: 2,751
    05-04-2011, 11:18 AM Go to last post
  46. Remote panel in crawlspace

    Started by Marc M, 05-03-2011 09:54 PM
    • Replies: 0
    • Views: 1,247
    05-03-2011, 09:54 PM Go to last post
  47. GFCI failure?

    Started by Jack Wingo, 05-02-2011 09:32 AM
    • Replies: 11
    • Views: 4,902
    05-03-2011, 09:58 AM Go to last post
  48. Cool Old house new wiring

    Started by Robert Mattison, 04-21-2011 04:50 PM
    • Replies: 44
    • Views: 15,097
    05-01-2011, 09:33 AM Go to last post
  49. wire for bonding csst

    Started by chris mcintyre, 04-30-2011 08:44 AM
    • Replies: 2
    • Views: 5,062
    05-01-2011, 07:46 AM Go to last post
  50. hot tub panel

    Started by Tony Vargas, 04-27-2011 07:42 AM
    • Replies: 9
    • Views: 2,450
    04-29-2011, 03:00 PM Go to last post
  51. Whats the point of this?

    Started by Marc M, 04-25-2011 10:00 PM
    • Replies: 28
    • Views: 3,411
    04-29-2011, 02:38 PM Go to last post
  52. Water pipes bonded - what year?

    Started by Randall Clark, 04-10-2011 07:20 PM
    • Replies: 18
    • Views: 4,257
    04-29-2011, 02:01 PM Go to last post
    • Replies: 4
    • Views: 1,687
    04-28-2011, 08:19 PM Go to last post
    • Replies: 3
    • Views: 1,799
    04-28-2011, 09:34 AM Go to last post
  53. A question about bonding

    Started by John Kogel, 04-18-2011 07:27 PM
    • Replies: 37
    • Views: 4,826
    04-26-2011, 05:23 PM Go to last post
  54. Conduit????

    Started by mathew stouffer, 04-20-2011 09:00 AM
    • Replies: 19
    • Views: 3,468
    04-26-2011, 03:59 PM Go to last post
  55. Generator subpanel...??

    Started by Steve Boyer, 04-20-2011 12:43 PM
    • Replies: 18
    • Views: 6,474
    04-25-2011, 10:37 AM Go to last post
    • Replies: 17
    • Views: 3,632
    04-24-2011, 11:34 PM Go to last post
  56. Panel in bathroom?

    Started by Tom Rees, 07-08-2010 02:34 PM
    2 Pages
    1 2
    • Replies: 73
    • Views: 18,138
    04-23-2011, 02:38 PM Go to last post
  57. SE Cable Protection

    Started by John Chenault, 04-22-2011 07:01 AM
    • Replies: 5
    • Views: 2,645
    04-22-2011, 12:15 PM Go to last post
  58. Cool Worn out 2-wire duplex receptacles

    Started by Robert Mattison, 04-18-2011 07:42 PM
    • Replies: 6
    • Views: 2,318
    04-20-2011, 04:08 PM Go to last post
  59. Messy crowded panel

    Started by mathew stouffer, 04-18-2011 08:46 PM
    • Replies: 25
    • Views: 5,392
    04-20-2011, 03:45 PM Go to last post
  60. Underground Service

    Started by Joe Arcaro, 04-20-2011 09:31 AM
    • Replies: 5
    • Views: 2,545
    04-20-2011, 03:31 PM Go to last post
  61. OUTLET BELOW BATHROOM SINK

    Started by CHARLIE VAN FLEET, 03-28-2011 03:22 PM
    • Replies: 36
    • Views: 15,143
    04-20-2011, 02:41 PM Go to last post
  62. Electrical panel qeustion

    Started by Charlie Crouthamel, 04-07-2011 06:34 PM
    • Replies: 49
    • Views: 6,221
    04-19-2011, 05:50 AM Go to last post
  63. What the heck is this?

    Started by JB Thompson, 04-18-2011 08:55 PM
    • Replies: 1
    • Views: 1,488
    04-18-2011, 09:03 PM Go to last post
  64. Light in Attic

    Started by Greg Subick, 04-17-2011 02:02 PM
    • Replies: 13
    • Views: 3,409
    04-18-2011, 11:56 AM Go to last post
  65. What size conductor is this ?

    Started by Robert Foster, 04-14-2011 12:42 PM
    • Replies: 3
    • Views: 2,127
    04-16-2011, 10:06 PM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •