1. 04-16-2007
    Views:
    87,848

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. "Scorched" breaker handles

    Started by Michael Thomas, 06-13-2011 08:24 PM
    • Replies: 9
    • Views: 2,385
    06-14-2011, 08:23 PM Go to last post
  2. Seeing is believing

    Started by Robert Foster, 06-09-2011 07:38 PM
    • Replies: 8
    • Views: 1,863
    06-14-2011, 07:04 PM Go to last post
  3. 12 G aluminum / copper wire nut

    Started by Jon mackay, 06-13-2011 11:46 AM
    • Replies: 5
    • Views: 4,259
    06-14-2011, 10:57 AM Go to last post
  4. Double breaker position in GE panel

    Started by John Kogel, 06-08-2011 10:48 PM
    • Replies: 16
    • Views: 4,489
    06-10-2011, 09:39 PM Go to last post
  5. What's this component called?

    Started by Marc M, 06-09-2011 10:09 PM
    • Replies: 13
    • Views: 2,563
    06-10-2011, 08:07 PM Go to last post
  6. Interconnected smoke alarms

    Started by Marc M, 06-08-2011 08:59 PM
    • Replies: 2
    • Views: 1,570
    06-09-2011, 08:45 AM Go to last post
  7. Surge arrestor

    Started by mathew stouffer, 05-30-2011 12:08 PM
    • Replies: 5
    • Views: 2,364
    06-07-2011, 07:07 PM Go to last post
  8. Light/fan inside bathroom shower

    Started by Thomas Thayer, 06-05-2011 05:35 PM
    • Replies: 17
    • Views: 34,719
    06-07-2011, 03:22 PM Go to last post
  9. FPE panel

    Started by Jon Errickson, 05-28-2011 11:11 PM
    • Replies: 31
    • Views: 4,488
    06-06-2011, 12:13 PM Go to last post
  10. How many wires per nut

    Started by Jon mackay, 06-06-2011 10:11 AM
    • Replies: 3
    • Views: 3,268
    06-06-2011, 11:56 AM Go to last post
  11. Hard wired clothes dryer

    Started by Jon mackay, 06-03-2011 04:34 PM
    • Replies: 4
    • Views: 5,452
    06-04-2011, 09:55 PM Go to last post
    • Replies: 15
    • Views: 2,253
    06-04-2011, 04:36 AM Go to last post
  12. 312.8 Changes

    Started by Jim Port, 06-02-2011 09:39 AM
    • Replies: 3
    • Views: 4,822
    06-03-2011, 10:05 AM Go to last post
  13. strange panel

    Started by Russell Melville, 06-02-2011 07:26 PM
    • Replies: 2
    • Views: 1,231
    06-03-2011, 06:47 AM Go to last post
    • Replies: 32
    • Views: 21,091
    06-02-2011, 11:54 AM Go to last post
  14. Double tapped lugs in service

    Started by mathew stouffer, 05-31-2011 02:33 PM
    • Replies: 10
    • Views: 3,537
    06-01-2011, 07:36 PM Go to last post
  15. Surge arrestor

    Started by mathew stouffer, 05-30-2011 12:29 PM
    • Replies: 2
    • Views: 1,712
    05-31-2011, 01:56 AM Go to last post
  16. Readily Accessible-question

    Started by Marc M, 05-29-2011 12:19 AM
    • Replies: 5
    • Views: 3,593
    05-29-2011, 09:39 PM Go to last post
  17. sec protection?

    Started by John Arnold, 05-27-2011 02:53 PM
    • Replies: 6
    • Views: 1,586
    05-28-2011, 06:59 AM Go to last post
  18. Service meter

    Started by JIM MURPHY, 05-26-2011 03:12 PM
    • Replies: 2
    • Views: 1,375
    05-27-2011, 12:24 PM Go to last post
  19. Mismatched Service Cable Sizes

    Started by Nick Ostrowski, 05-24-2011 07:36 AM
    • Replies: 18
    • Views: 3,245
    05-26-2011, 06:14 AM Go to last post
    • Replies: 3
    • Views: 1,527
    05-25-2011, 10:09 PM Go to last post
    • Replies: 5
    • Views: 2,342
    05-25-2011, 04:59 PM Go to last post
    • Replies: 6
    • Views: 1,619
    05-25-2011, 08:35 AM Go to last post
    • Replies: 4
    • Views: 1,431
    05-24-2011, 08:22 PM Go to last post
  20. Refrigerator on GFCI circuit

    Started by Phillip Stojanik, 07-28-2007 03:04 PM
    • Replies: 32
    • Views: 34,982
    05-23-2011, 09:17 PM Go to last post
    • Replies: 3
    • Views: 2,275
    05-23-2011, 08:23 AM Go to last post
  21. Main feeder looped around branch circuits

    Started by Don Halligan, 05-20-2011 08:59 PM
    • Replies: 3
    • Views: 1,777
    05-21-2011, 12:21 PM Go to last post
  22. Branch Panel Question

    Started by Chris Skoczylas, 05-19-2011 05:00 PM
    • Replies: 3
    • Views: 1,272
    05-19-2011, 07:11 PM Go to last post
  23. New Item on panel Never seen before

    Started by Thomas Tadd, 05-17-2011 08:39 PM
    • Replies: 8
    • Views: 1,663
    05-19-2011, 07:10 PM Go to last post
  24. Cutler Hammer Breakers

    Started by Marc Morin, 11-10-2010 08:07 PM
    • Replies: 5
    • Views: 5,363
    05-19-2011, 11:01 AM Go to last post
  25. Rats nest in panel

    Started by mathew stouffer, 05-12-2011 07:53 AM
    • Replies: 19
    • Views: 4,617
    05-18-2011, 08:09 PM Go to last post
  26. Is this 100 amp or 200 amp service?

    Started by Wayne Turley, 02-01-2009 01:26 AM
    • Replies: 18
    • Views: 80,645
    05-17-2011, 09:18 PM Go to last post
  27. Condo mechanical room

    Started by Peter Louis, 05-16-2011 10:35 PM
    • Replies: 4
    • Views: 3,007
    05-17-2011, 07:03 PM Go to last post
  28. 100 amp service

    Started by Len Couey, 05-12-2011 03:40 PM
    • Replies: 11
    • Views: 6,515
    05-17-2011, 04:46 AM Go to last post
  29. No power & looking for an answer why

    Started by Bill Wieczorek, 05-16-2011 08:47 AM
    • Replies: 6
    • Views: 2,003
    05-16-2011, 07:23 PM Go to last post
  30. Panel behind refrigerator

    Started by wayne soper, 05-16-2011 03:18 PM
    • Replies: 4
    • Views: 1,818
    05-16-2011, 05:28 PM Go to last post
  31. 208V 3-ph - no neutral

    Started by Ken Amelin, 06-16-2010 07:19 AM
    • Replies: 39
    • Views: 11,941
    05-15-2011, 12:13 PM Go to last post
  32. GFCI circuit servicing two or more rooms

    Started by Bill Anglin, 05-12-2011 09:51 PM
    • Replies: 13
    • Views: 8,513
    05-14-2011, 01:52 PM Go to last post
  33. Breaker

    Started by Tom Rees, 05-11-2011 04:57 PM
    • Replies: 10
    • Views: 1,722
    05-12-2011, 06:15 AM Go to last post
  34. what a mess

    Started by John Arnold, 05-11-2011 02:35 PM
    • Replies: 3
    • Views: 1,297
    05-11-2011, 08:12 PM Go to last post
  35. 220 outlet in bedroom

    Started by mathew stouffer, 05-11-2011 07:58 AM
    • Replies: 6
    • Views: 1,526
    05-11-2011, 01:22 PM Go to last post
  36. I don't get it....

    Started by Matt Fellman, 05-02-2011 05:50 PM
    • Replies: 10
    • Views: 2,090
    05-10-2011, 06:13 PM Go to last post
  37. Electrical panel connections

    Started by Don Horn, 02-25-2011 09:55 AM
    • Replies: 9
    • Views: 1,909
    05-10-2011, 10:48 AM Go to last post
  38. Using Dimmers with CFLs

    Started by craig laMere, 05-09-2011 12:27 PM
    • Replies: 0
    • Views: 1,084
    05-09-2011, 12:27 PM Go to last post
  39. Metal pool filters-bonding.

    Started by Marc M, 04-27-2011 12:15 PM
    • Replies: 33
    • Views: 5,091
    05-09-2011, 05:07 AM Go to last post
  40. Main Electrical "Maximum" Feed Length

    Started by Rich Sumen, 05-04-2011 01:43 PM
    • Replies: 14
    • Views: 14,686
    05-08-2011, 10:54 AM Go to last post
  41. Cool House Electrical Panel Directory

    Started by Robert Mattison, 05-01-2011 01:41 PM
    • Replies: 21
    • Views: 4,788
    05-07-2011, 06:53 AM Go to last post
  42. Overhead Wiring

    Started by Stephen G Sheldon, 04-30-2011 03:33 PM
    • Replies: 7
    • Views: 2,410
    05-06-2011, 08:28 PM Go to last post
  43. Wiring on attic floor

    Started by Jon mackay, 09-11-2010 07:09 AM
    • Replies: 51
    • Views: 16,534
    05-04-2011, 01:25 PM Go to last post
  44. Remote panel in crawlspace

    Started by Marc M, 05-03-2011 10:55 PM
    • Replies: 7
    • Views: 2,717
    05-04-2011, 12:18 PM Go to last post
  45. Remote panel in crawlspace

    Started by Marc M, 05-03-2011 10:54 PM
    • Replies: 0
    • Views: 1,227
    05-03-2011, 10:54 PM Go to last post
  46. GFCI failure?

    Started by Jack Wingo, 05-02-2011 10:32 AM
    • Replies: 11
    • Views: 4,841
    05-03-2011, 10:58 AM Go to last post
  47. Cool Old house new wiring

    Started by Robert Mattison, 04-21-2011 05:50 PM
    • Replies: 44
    • Views: 14,951
    05-01-2011, 10:33 AM Go to last post
  48. wire for bonding csst

    Started by chris mcintyre, 04-30-2011 09:44 AM
    • Replies: 2
    • Views: 4,955
    05-01-2011, 08:46 AM Go to last post
  49. hot tub panel

    Started by Tony Vargas, 04-27-2011 08:42 AM
    • Replies: 9
    • Views: 2,426
    04-29-2011, 04:00 PM Go to last post
  50. Whats the point of this?

    Started by Marc M, 04-25-2011 11:00 PM
    • Replies: 28
    • Views: 3,376
    04-29-2011, 03:38 PM Go to last post
  51. Water pipes bonded - what year?

    Started by Randall Clark, 04-10-2011 08:20 PM
    • Replies: 18
    • Views: 4,210
    04-29-2011, 03:01 PM Go to last post
    • Replies: 4
    • Views: 1,653
    04-28-2011, 09:19 PM Go to last post
    • Replies: 3
    • Views: 1,775
    04-28-2011, 10:34 AM Go to last post
  52. A question about bonding

    Started by John Kogel, 04-18-2011 08:27 PM
    • Replies: 37
    • Views: 4,756
    04-26-2011, 06:23 PM Go to last post
  53. Conduit????

    Started by mathew stouffer, 04-20-2011 10:00 AM
    • Replies: 19
    • Views: 3,435
    04-26-2011, 04:59 PM Go to last post
  54. Generator subpanel...??

    Started by Steve Boyer, 04-20-2011 01:43 PM
    • Replies: 18
    • Views: 6,403
    04-25-2011, 11:37 AM Go to last post
    • Replies: 17
    • Views: 3,610
    04-25-2011, 12:34 AM Go to last post
  55. Panel in bathroom?

    Started by Tom Rees, 07-08-2010 03:34 PM
    2 Pages
    1 2
    • Replies: 73
    • Views: 17,956
    04-23-2011, 03:38 PM Go to last post
  56. SE Cable Protection

    Started by John Chenault, 04-22-2011 08:01 AM
    • Replies: 5
    • Views: 2,613
    04-22-2011, 01:15 PM Go to last post
  57. Cool Worn out 2-wire duplex receptacles

    Started by Robert Mattison, 04-18-2011 08:42 PM
    • Replies: 6
    • Views: 2,290
    04-20-2011, 05:08 PM Go to last post
  58. Messy crowded panel

    Started by mathew stouffer, 04-18-2011 09:46 PM
    • Replies: 25
    • Views: 5,321
    04-20-2011, 04:45 PM Go to last post
  59. Underground Service

    Started by Joe Arcaro, 04-20-2011 10:31 AM
    • Replies: 5
    • Views: 2,516
    04-20-2011, 04:31 PM Go to last post
  60. OUTLET BELOW BATHROOM SINK

    Started by CHARLIE VAN FLEET, 03-28-2011 04:22 PM
    • Replies: 36
    • Views: 14,812
    04-20-2011, 03:41 PM Go to last post
  61. Electrical panel qeustion

    Started by Charlie Crouthamel, 04-07-2011 07:34 PM
    • Replies: 49
    • Views: 6,201
    04-19-2011, 06:50 AM Go to last post
  62. What the heck is this?

    Started by JB Thompson, 04-18-2011 09:55 PM
    • Replies: 1
    • Views: 1,460
    04-18-2011, 10:03 PM Go to last post
  63. Light in Attic

    Started by Greg Subick, 04-17-2011 03:02 PM
    • Replies: 13
    • Views: 3,378
    04-18-2011, 12:56 PM Go to last post
  64. What size conductor is this ?

    Started by Robert Foster, 04-14-2011 01:42 PM
    • Replies: 3
    • Views: 2,100
    04-16-2011, 11:06 PM Go to last post
  65. 120 volt line-to-line dwelling wiring system

    Started by Fred Warner, 02-14-2009 09:59 AM
    • Replies: 23
    • Views: 5,683
    04-15-2011, 09:14 PM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •