  1. Main panel wired like a sub?

    Started by Andy Jarchow, 03-30-2011 10:12 AM
    • Replies: 10
    • Views: 4,395
    03-30-2011, 04:18 PM Go to last post
  2. Phone wires routed into home with SEC

    Started by Scott Latosky, 03-27-2011 05:57 PM
    • Replies: 9
    • Views: 5,221
    03-29-2011, 08:51 AM Go to last post
  3. new home bathroom branch circuit

    Started by Mike Picarello, 03-27-2011 12:35 PM
    • Replies: 6
    • Views: 12,887
    03-28-2011, 10:01 AM Go to last post
  4. Light fixture on metal heating duct.

    Started by Rich Sumen, 03-22-2011 01:40 PM
    • Replies: 17
    • Views: 14,834
    03-28-2011, 05:54 AM Go to last post
  5. Power meter

    Started by JIM MURPHY, 03-24-2011 06:29 PM
    • Replies: 8
    • Views: 9,021
    03-27-2011, 10:48 PM Go to last post
  6. Grounding

    Started by Scott Latosky, 12-18-2010 07:41 AM
    • Replies: 40
    • Views: 8,726
    03-27-2011, 03:07 PM Go to last post
  7. Tidbits

    Started by Bill Kriegh, 03-26-2011 03:42 AM
    • Replies: 4
    • Views: 2,928
    03-26-2011, 09:04 AM Go to last post
  8. Hot Box

    Started by Bill Kriegh, 03-26-2011 02:21 AM
    • Replies: 0
    • Views: 2,987
    03-26-2011, 02:21 AM Go to last post
  9. Bonding issue

    Started by Dave Mortensen, 03-22-2011 12:06 PM
    • Replies: 26
    • Views: 7,358
    03-25-2011, 07:03 PM Go to last post
  10. generous working space

    Started by Robert Foster, 03-24-2011 12:56 PM
    • Replies: 2
    • Views: 3,186
    03-24-2011, 02:05 PM Go to last post
  11. stove top tap box wiring

    Started by Michael Bronner, 03-21-2011 01:27 PM
    • Replies: 3
    • Views: 5,142
    03-24-2011, 08:26 AM Go to last post
    • Replies: 31
    • Views: 16,045
    03-23-2011, 05:41 PM Go to last post
  12. Max amperage off a sub panel?

    Started by Rich Sumen, 03-16-2011 02:32 PM
    • Replies: 41
    • Views: 61,312
    03-23-2011, 07:11 AM Go to last post
  13. GFCI issue

    Started by John Dirks Jr, 03-20-2011 11:20 AM
    • Replies: 14
    • Views: 6,249
    03-23-2011, 06:10 AM Go to last post
  14. From the old board, Abandon Wiring

    Started by Tim Moreira, 04-01-2007 11:48 PM
    • Replies: 2
    • Views: 4,877
    03-21-2011, 06:40 AM Go to last post
  15. Dbl lugged neutral in sub-panel, again

    Started by Dan Harris, 02-15-2011 07:01 PM
    • Replies: 10
    • Views: 6,656
    03-20-2011, 08:29 AM Go to last post
    • Replies: 8
    • Views: 4,181
    03-19-2011, 02:35 PM Go to last post
  16. Breaker Arrangement

    Started by Paul Johnston, 03-18-2011 01:47 PM
    • Replies: 2
    • Views: 2,876
    03-18-2011, 02:24 PM Go to last post
  17. Feeder cables, penetration through box

    Started by mathew stouffer, 03-16-2011 05:23 PM
    • Replies: 1
    • Views: 2,848
    03-17-2011, 11:12 AM Go to last post
  18. Pushmatic Spilt Buss?

    Started by Michael Thomas, 03-15-2011 04:21 PM
    • Replies: 8
    • Views: 4,458
    03-16-2011, 01:39 PM Go to last post
    • Replies: 10
    • Views: 6,125
    03-16-2011, 07:39 AM Go to last post
  19. Any defects?

    Started by Joseph Peake, 03-15-2011 08:02 AM
    • Replies: 4
    • Views: 3,367
    03-16-2011, 01:10 AM Go to last post
  20. Double Tapped - Stranded vs Solid

    Started by Andrew Kolar, 03-15-2011 07:08 PM
    • Replies: 1
    • Views: 2,881
    03-15-2011, 08:07 PM Go to last post
  21. Unanswered questions

    Started by Jim Port, 03-14-2011 02:46 PM
    • Replies: 1
    • Views: 2,550
    03-14-2011, 03:17 PM Go to last post
    • Replies: 10
    • Views: 8,029
    03-14-2011, 07:43 AM Go to last post
  22. ceiling fans in bathrooms

    Started by brianmiller, 03-12-2011 05:51 AM
    • Replies: 5
    • Views: 8,111
    03-13-2011, 11:13 AM Go to last post
  23. box fill in commercial electrical

    Started by jason schatz, 03-12-2011 03:51 PM
    • Replies: 2
    • Views: 2,668
    03-12-2011, 07:51 PM Go to last post
  24. Single Phase Panel in 3 Phase building

    Started by Andrew Kolar, 03-10-2011 01:04 PM
    • Replies: 6
    • Views: 9,286
    03-12-2011, 07:18 PM Go to last post
  25. Multi-wire circuits

    Started by Terry Beck, 03-08-2011 06:14 PM
    • Replies: 23
    • Views: 10,530
    03-11-2011, 08:32 PM Go to last post
  26. Awesome Electrical "Improvement"

    Started by Bruce Breedlove, 03-10-2011 08:54 PM
    • Replies: 2
    • Views: 3,476
    03-11-2011, 05:27 PM Go to last post
  27. Light Bulb Madness

    Started by Nick Ostrowski, 03-02-2011 12:34 PM
    • Replies: 37
    • Views: 8,512
    03-11-2011, 08:10 AM Go to last post
  28. framing/sheetrock against panel cover

    Started by Randall Clark, 03-07-2011 06:45 PM
    • Replies: 12
    • Views: 5,375
    03-10-2011, 07:43 AM Go to last post
  29. Outlet requirement

    Started by mathew stouffer, 03-09-2011 09:50 PM
    • Replies: 2
    • Views: 2,815
    03-10-2011, 06:59 AM Go to last post
  30. Backfed Service Panel

    Started by Bruce Ramsey, 03-09-2011 09:15 PM
    • Replies: 0
    • Views: 2,433
    03-09-2011, 09:15 PM Go to last post
    • Replies: 39
    • Views: 10,964
    03-08-2011, 11:35 AM Go to last post
  31. Pot lights at suspended ceiling

    Started by Jon mackay, 03-06-2011 07:28 AM
    • Replies: 4
    • Views: 6,290
    03-07-2011, 06:31 PM Go to last post
  32. Where is the Fuse ?

    Started by H.L. ( Buddy ) Ligon 111, 03-04-2011 04:17 AM
    • Replies: 2
    • Views: 3,318
    03-07-2011, 11:58 AM Go to last post
  33. 3 Phase Electrical

    Started by Andrew Kolar, 03-02-2011 09:07 AM
    • Replies: 7
    • Views: 6,546
    03-05-2011, 08:39 PM Go to last post
    • Replies: 19
    • Views: 6,436
    03-05-2011, 02:19 PM Go to last post
  34. conductor under screw of the breaker

    Started by Bert de Haan, 02-25-2011 03:36 PM
    • Replies: 3
    • Views: 2,891
    03-05-2011, 06:45 AM Go to last post
  35. Generator Disconnect

    Started by Paul Johnston, 02-25-2011 02:44 AM
    • Replies: 6
    • Views: 3,593
    03-02-2011, 05:05 PM Go to last post
  36. Exclamation How is this working!

    Started by Trent Tarter, 02-27-2011 08:29 PM
    • Replies: 15
    • Views: 5,017
    03-01-2011, 08:33 PM Go to last post
  37. Disconnect box for hot tubs

    Started by mathew stouffer, 02-18-2011 11:20 PM
    • Replies: 16
    • Views: 18,656
    02-26-2011, 06:41 PM Go to last post
  38. Electrical panel connection

    Started by Don Horn, 02-25-2011 10:00 AM
    • Replies: 0
    • Views: 2,539
    02-25-2011, 10:00 AM Go to last post
  39. main diconnect

    Started by steve mcgown, 02-21-2011 09:17 PM
    • Replies: 18
    • Views: 6,446
    02-23-2011, 09:16 PM Go to last post
  40. Code For GFIs on Center Islands

    Started by Nick Ostrowski, 02-22-2011 04:17 PM
    • Replies: 5
    • Views: 11,348
    02-22-2011, 07:01 PM Go to last post
  41. Would you remove this panel cover?

    Started by Robert Smith, 02-19-2011 06:30 PM
    • Replies: 14
    • Views: 5,680
    02-21-2011, 02:55 PM Go to last post
  42. Cabinet track lighting

    Started by mathew stouffer, 02-16-2011 09:00 PM
    • Replies: 8
    • Views: 4,446
    02-20-2011, 10:34 PM Go to last post
  43. Fan in bathtub enclosure

    Started by mathew stouffer, 02-15-2011 08:25 AM
    • Replies: 5
    • Views: 3,571
    02-18-2011, 06:07 PM Go to last post
  44. Service drop

    Started by mathew stouffer, 02-17-2011 09:29 PM
    • Replies: 6
    • Views: 3,805
    02-18-2011, 06:03 PM Go to last post
  45. Service ground connection

    Started by Ken Amelin, 02-16-2011 05:55 AM
    • Replies: 13
    • Views: 9,445
    02-18-2011, 08:23 AM Go to last post
  46. Electrical Panel

    Started by Sam Morris, 02-17-2011 07:22 PM
    • Replies: 5
    • Views: 3,944
    02-18-2011, 07:30 AM Go to last post
  47. Water pipe bond

    Started by Marc M, 02-05-2011 10:02 PM
    • Replies: 47
    • Views: 21,310
    02-16-2011, 08:28 PM Go to last post
  48. Wiring over fiberglass insulation

    Started by Jon mackay, 02-15-2011 02:32 PM
    • Replies: 4
    • Views: 3,420
    02-16-2011, 07:01 AM Go to last post
  49. 4/0 or 2/0 Aluminium Cable

    Started by mathew stouffer, 02-09-2011 08:44 AM
    • Replies: 58
    • Views: 17,963
    02-16-2011, 12:52 AM Go to last post
  50. Red face Panel Box

    Started by mark ferrell, 02-11-2011 06:24 AM
    • Replies: 4
    • Views: 3,326
    02-11-2011, 02:11 PM Go to last post
  51. Kitchen island

    Started by mathew stouffer, 02-08-2011 10:14 PM
    • Replies: 20
    • Views: 7,417
    02-11-2011, 01:38 PM Go to last post
  52. Dimmer Switch on Bathroom Heat Lamp

    Started by Daniel Leung, 02-10-2011 05:10 AM
    • Replies: 5
    • Views: 6,996
    02-10-2011, 07:08 PM Go to last post
  53. Uncle Buck's Clothes Closet

    Started by Jerry McCarthy, 02-05-2011 05:00 PM
    • Replies: 5
    • Views: 4,714
    02-08-2011, 09:31 PM Go to last post
  54. Regarding service mast andSEC

    Started by Ross Neag, 01-31-2011 09:32 PM
    • Replies: 12
    • Views: 7,473
    02-07-2011, 02:46 PM Go to last post
  55. multiple meter question

    Started by Scott Lee, 02-02-2011 09:11 AM
    • Replies: 15
    • Views: 5,216
    02-07-2011, 07:41 AM Go to last post
  56. Electrical Panel

    Started by Gary Winfield, 02-01-2011 07:04 PM
    • Replies: 16
    • Views: 7,181
    02-03-2011, 03:50 PM Go to last post
  57. What size are these service wires?

    Started by sidney alstad, 01-31-2011 07:00 PM
    • Replies: 11
    • Views: 5,533
    02-03-2011, 10:35 AM Go to last post
  58. Covered Service Drop

    Started by Stuart Brooks, 02-02-2011 10:19 AM
    • Replies: 6
    • Views: 4,302
    02-02-2011, 06:34 PM Go to last post
  59. funny things on Craigslist

    Started by Jack Feldmann, 02-01-2011 10:28 AM
    • Replies: 2
    • Views: 3,416
    02-01-2011, 02:39 PM Go to last post
  60. Service panel in bathroom

    Started by JIM MURPHY, 01-31-2011 09:17 PM
    • Replies: 3
    • Views: 3,628
    02-01-2011, 08:56 AM Go to last post
  61. Whats the name of this piece?

    Started by Marc M, 01-31-2011 09:29 PM
    • Replies: 2
    • Views: 3,161
    02-01-2011, 08:21 AM Go to last post
  62. A question about Multi-branch circuits

    Started by Rob Colecchi, 01-31-2011 07:36 PM
    • Replies: 2
    • Views: 3,330
    02-01-2011, 06:07 AM Go to last post
  63. Rating of split buss panel.

    Started by Roger Kautz, 01-27-2011 06:41 PM
    • Replies: 25
    • Views: 14,096
    01-31-2011, 05:44 PM Go to last post
  64. What do you think is this ok?

    Started by Andy Jarchow, 01-29-2011 08:25 PM
    • Replies: 13
    • Views: 5,617
    01-31-2011, 05:29 PM Go to last post
  65. GFCI Outlet

    Started by Sam Morris, 01-27-2011 05:05 PM
    • Replies: 6
    • Views: 5,672
    01-31-2011, 11:21 AM Go to last post
  66. Faucet to Electrical outlet (GFI)

    Started by Frank Albanello, 01-24-2011 06:41 AM
    • Replies: 17
    • Views: 55,570
    01-30-2011, 05:55 AM Go to last post
  67. Barrel Crimps

    Started by Richard Thacker, 01-21-2011 10:46 AM
    • Replies: 2
    • Views: 3,793
    01-24-2011, 05:17 AM Go to last post
  68. wire size

    Started by william siegel, 01-20-2011 03:32 PM
    • Replies: 8
    • Views: 6,752
    01-21-2011, 08:11 AM Go to last post
  69. Older ITE Main Panel

    Started by Patrick Knight, 01-20-2011 10:09 PM
    • Replies: 1
    • Views: 3,794
    01-20-2011, 10:42 PM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •