1. 04-16-2007
    Views:
    1,669,071

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. Meter box - mounting height.

    Started by Ken Amelin, 07-19-2018 11:40 AM
    • Replies: 16
    • Views: 9,542
    07-25-2018, 08:43 AM Go to last post
  2. Three phase residential supply

    Started by Bob Ozbirn, 06-21-2018 06:33 AM
    • Replies: 3
    • Views: 5,629
    07-20-2018, 07:51 PM Go to last post
    • Replies: 10
    • Views: 7,230
    07-12-2018, 06:39 PM Go to last post
  3. Ground strap jumper

    Started by Daniel Rogers, 06-21-2011 07:52 PM
    • Replies: 28
    • Views: 26,188
    07-05-2018, 04:18 AM Go to last post
  4. Aluminum wiring thru house

    Started by Rick Beeman, 06-28-2018 04:18 AM
    • Replies: 5
    • Views: 6,646
    07-02-2018, 08:10 PM Go to last post
    • Replies: 5
    • Views: 4,808
    06-20-2018, 01:20 PM Go to last post
  5. Exposed height of ground rod

    Started by Scott Laird, 06-01-2018 01:50 PM
    • Replies: 10
    • Views: 23,399
    06-06-2018, 04:47 PM Go to last post
  6. Wiring hanging from joists

    Started by Richard Roshak, 04-08-2018 04:39 PM
    • Replies: 4
    • Views: 13,516
    04-09-2018, 04:39 AM Go to last post
  7. terminology

    Started by John Dirks Jr, 04-03-2018 06:33 PM
    • Replies: 2
    • Views: 4,352
    04-03-2018, 07:45 PM Go to last post
  8. Is it LIVE?

    Started by Elizabeth Chambers, 03-31-2018 12:03 AM
    • Replies: 19
    • Views: 5,640
    04-03-2018, 04:06 PM Go to last post
  9. Non-GFCI outlet on bar cabinet

    Started by Sam Morris, 03-20-2018 07:13 PM
    • Replies: 10
    • Views: 6,182
    03-22-2018, 08:54 PM Go to last post
  10. Tub light!

    Started by Jeff Zehnder, 03-22-2018 01:36 PM
    • Replies: 4
    • Views: 2,505
    03-22-2018, 06:44 PM Go to last post
  11. Combustibles in cabinet Looking for the code plz

    Started by Marc M, 02-22-2018 10:39 PM
    • Replies: 7
    • Views: 8,180
    02-24-2018, 06:07 AM Go to last post
  12. Copper core with aluminum clad ??

    Started by Sam Morris, 02-02-2018 08:42 PM
    • Replies: 5
    • Views: 7,357
    02-22-2018, 01:03 AM Go to last post
  13. A good Zinsco???

    Started by Rick Bunzel, 08-26-2017 02:58 PM
    • Replies: 22
    • Views: 13,357
    01-26-2018, 10:38 AM Go to last post
    • Replies: 1
    • Views: 3,682
    01-24-2018, 12:48 PM Go to last post
  14. CSST direct to meter

    Started by Don Hawley, 01-16-2018 04:55 PM
    • Replies: 0
    • Views: 5,143
    01-16-2018, 04:55 PM Go to last post
  15. 3-wire vs 4-wire

    Started by Chris Weekly, 01-10-2018 11:45 PM
    • Replies: 14
    • Views: 5,445
    01-15-2018, 10:49 AM Go to last post
    • Replies: 1
    • Views: 5,165
    12-31-2017, 08:39 PM Go to last post
  16. How do you write this up

    Started by Don Hawley, 12-29-2017 08:13 AM
    • Replies: 3
    • Views: 4,124
    12-30-2017, 05:34 PM Go to last post
  17. SERVICE QUESTION

    Started by ROBERT YOUNG, 12-21-2017 05:07 AM
    • Replies: 9
    • Views: 5,406
    12-21-2017, 05:25 PM Go to last post
  18. GFCI Protected?

    Started by Donald Stauffer, 12-05-2017 10:20 PM
    • Replies: 13
    • Views: 6,318
    12-09-2017, 01:18 PM Go to last post
  19. Secondary Panel Issue ?

    Started by Sam Morris, 11-29-2017 03:31 PM
    • Replies: 9
    • Views: 4,495
    11-30-2017, 12:37 PM Go to last post
  20. AL cable/wire history

    Started by ROBERT YOUNG, 11-27-2017 05:26 AM
    • Replies: 0
    • Views: 2,675
    11-27-2017, 05:26 AM Go to last post
  21. electric shock on dishwasher

    Started by Ben Im, 09-07-2017 09:17 PM
    • Replies: 3
    • Views: 3,918
    11-11-2017, 03:20 PM Go to last post
  22. What's up with this panel? Amp? No disco?

    Started by Crosseyes, 11-05-2017 10:22 AM
    • Replies: 5
    • Views: 4,186
    11-06-2017, 09:47 AM Go to last post
    • Replies: 15
    • Views: 6,051
    11-06-2017, 05:41 AM Go to last post
  23. Condo panel and transfer switch question

    Started by HJ Gallego, 10-30-2017 09:42 PM
    • Replies: 12
    • Views: 6,524
    11-03-2017, 11:18 AM Go to last post
  24. Bonding of metal piping systems

    Started by Ken Amelin, 10-22-2017 07:14 AM
    • Replies: 4
    • Views: 4,072
    10-22-2017, 02:32 PM Go to last post
  25. Question Hanging Bulbs Code

    Started by Stuart S, 10-09-2017 02:29 PM
    fixtures, lighting
    • Replies: 3
    • Views: 4,144
    10-11-2017, 06:02 AM Go to last post
    • Replies: 15
    • Views: 4,574
    10-08-2017, 05:32 AM Go to last post
  26. Equipment grounds are bundled together

    Started by Sam Morris, 09-18-2017 03:33 PM
    • Replies: 1
    • Views: 4,025
    09-18-2017, 03:41 PM Go to last post
  27. GEC question

    Started by ROBERT YOUNG, 09-14-2017 05:05 AM
    • Replies: 10
    • Views: 4,031
    09-15-2017, 09:21 AM Go to last post
  28. Outlet "Tester" sampler panel

    Started by Bob Sisson, 09-12-2017 12:52 PM
    • Replies: 3
    • Views: 2,826
    09-12-2017, 08:22 PM Go to last post
  29. Canada gets this right, too bad the US doesn't

    Started by Jerry Peck, 08-25-2017 07:53 AM
    • Replies: 2
    • Views: 2,677
    08-26-2017, 12:40 PM Go to last post
  30. Bonding question

    Started by ROBERT YOUNG, 08-24-2017 04:00 AM
    • Replies: 13
    • Views: 3,548
    08-26-2017, 05:01 AM Go to last post
  31. HI training

    Started by Brad Richter, 08-22-2017 03:00 PM
    • Replies: 4
    • Views: 3,030
    08-23-2017, 05:17 PM Go to last post
  32. Main Lug labeled 2-250

    Started by Sam Morris, 07-27-2017 07:20 PM
    • Replies: 9
    • Views: 6,937
    07-31-2017, 06:02 PM Go to last post
  33. Unknown Gizmo?

    Started by Michael Chambers, 07-30-2017 11:53 PM
    • Replies: 7
    • Views: 3,014
    07-31-2017, 04:06 PM Go to last post
  34. Service equipment height.

    Started by ROBERT YOUNG, 07-17-2017 10:22 AM
    • Replies: 9
    • Views: 5,916
    07-19-2017, 08:07 PM Go to last post
  35. 240 volt breakers

    Started by Richard Roshak, 06-26-2017 03:45 PM
    • Replies: 16
    • Views: 7,178
    07-08-2017, 12:17 PM Go to last post
    • Replies: 5
    • Views: 5,562
    07-08-2017, 01:26 AM Go to last post
    • Replies: 23
    • Views: 9,189
    07-05-2017, 05:43 PM Go to last post
  36. Bundled conductors

    Started by Ken Amelin, 06-13-2017 12:57 PM
    • Replies: 15
    • Views: 8,079
    06-27-2017, 12:49 PM Go to last post
    • Replies: 23
    • Views: 10,214
    06-27-2017, 05:14 AM Go to last post
  37. Tap for subpanel into main lug

    Started by Ernie Simpson, 06-08-2017 05:04 PM
    • Replies: 14
    • Views: 9,472
    06-26-2017, 08:37 PM Go to last post
    • Replies: 12
    • Views: 5,330
    06-25-2017, 05:22 PM Go to last post
  38. Sub-panel wiring

    Started by Richard Roshak, 06-08-2017 04:16 PM
    • Replies: 8
    • Views: 4,727
    06-25-2017, 02:48 PM Go to last post
  39. Stairway lights and hallway lights are tied.

    Started by Ben Im, 06-06-2017 09:45 PM
    end, hallway, light, lights, stairway
    • Replies: 7
    • Views: 4,458
    06-08-2017, 11:35 AM Go to last post
  40. Double taped breakers

    Started by Don Hawley, 05-07-2017 11:32 AM
    agent, breakers, double, provide, reference;
    • Replies: 7
    • Views: 7,179
    06-02-2017, 08:07 PM Go to last post
  41. Generator lock out switch.

    Started by Ken Amelin, 05-11-2017 07:49 AM
    • Replies: 6
    • Views: 5,532
    05-26-2017, 12:50 PM Go to last post
  42. Green Oxidation in Service Panel

    Started by Lon Henderson, 05-01-2017 04:15 PM
    • Replies: 4
    • Views: 6,251
    05-04-2017, 07:18 AM Go to last post
    • Replies: 9
    • Views: 7,279
    05-04-2017, 05:04 AM Go to last post
  43. Transfer Switch

    Started by Gunnar Alquist, 04-14-2017 01:03 PM
    • Replies: 16
    • Views: 7,010
    04-25-2017, 05:59 AM Go to last post
  44. Transfer switch

    Started by Scott Turner, 04-21-2017 07:11 PM
    • Replies: 0
    • Views: 2,750
    04-21-2017, 07:11 PM Go to last post
  45. GFCI BREAKER RED TRIP LIGHT

    Started by CHARLIE VAN FLEET, 04-08-2017 04:21 PM
    breaker, gfci, light, red, trip
    • Replies: 12
    • Views: 8,620
    04-14-2017, 07:19 PM Go to last post
  46. NEC Bonding Article

    Started by Gunnar Alquist, 03-29-2017 09:46 AM
    bonding, disconnecting, equipment, means, service
    • Replies: 10
    • Views: 5,354
    04-02-2017, 06:47 PM Go to last post
  47. GFCI for sump pump or sewage ejectors

    Started by Don Hawley, 03-22-2017 05:30 AM
    • Replies: 7
    • Views: 14,730
    03-26-2017, 05:16 AM Go to last post
  48. Electrical Service Rating - HELP!

    Started by Tom Cissell, 11-02-2012 02:04 PM
    • Replies: 41
    • Views: 13,516
    03-19-2017, 05:04 PM Go to last post
  49. AKA sub-panel

    Started by Sam Morris, 03-09-2017 06:49 PM
    • Replies: 22
    • Views: 5,945
    03-13-2017, 08:18 PM Go to last post
  50. New GFCI

    Started by Jim Robinson, 05-28-2016 05:51 AM
    • Replies: 7
    • Views: 4,442
    03-07-2017, 09:49 AM Go to last post
  51. Breaker Securement

    Started by Raymond Wand, 10-11-2016 05:48 PM
    • Replies: 10
    • Views: 5,461
    03-06-2017, 11:27 PM Go to last post
  52. Panel manufacturer required

    Started by ROBERT YOUNG, 06-09-2016 08:52 AM
    • Replies: 2
    • Views: 3,708
    03-06-2017, 11:06 PM Go to last post
  53. Kentucky Home Inspectors and FPE panels

    Started by Scott Patterson, 12-04-2007 03:42 PM
    • Replies: 61
    • Views: 18,272
    03-02-2017, 11:07 AM Go to last post
  54. Use your camera as a step ladder.

    Started by Garry Sorrells, 02-22-2017 07:22 PM
    • Replies: 5
    • Views: 3,741
    02-23-2017, 09:44 AM Go to last post
  55. are wago connectors code compliant 2009 IRC

    Started by Jim Bunton, 02-20-2017 02:23 PM
    code, compliant, connectors, irc, wago
    • Replies: 2
    • Views: 4,388
    02-21-2017, 04:39 AM Go to last post
  56. six throws to shut off power ?

    Started by George Eberle, 02-13-2017 10:22 AM
    • Replies: 8
    • Views: 4,671
    02-16-2017, 05:33 PM Go to last post
  57. Hello everyone

    Started by George Eberle, 02-13-2017 10:00 AM
    george, post, power, shortly, thread
    • Replies: 0
    • Views: 2,239
    02-13-2017, 10:00 AM Go to last post
    • Replies: 5
    • Views: 3,340
    02-05-2017, 01:12 PM Go to last post
  58. electrical narrative required

    Started by ROBERT YOUNG, 02-01-2017 06:21 PM
    • Replies: 4
    • Views: 3,592
    02-02-2017, 04:32 AM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •