1. 04-16-2007
    Views:
    1,989,528

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. Texas SOP-Appliance Grounding and Bonding

    Started by Joe Billman, 01-07-2009 06:53 AM
    • Replies: 12
    • Views: 8,667
    01-07-2009, 12:55 PM Go to last post
  2. 3-light circuit tester

    Started by Vern Heiler, 12-29-2008 10:48 AM
    • Replies: 34
    • Views: 19,352
    01-07-2009, 08:18 AM Go to last post
  3. Amperage on new house

    Started by Jim Robinson, 01-05-2009 04:43 PM
    • Replies: 10
    • Views: 7,990
    01-06-2009, 09:20 AM Go to last post
  4. Disconnect for wall oven

    Started by Michael Thomas, 01-05-2009 07:20 AM
    • Replies: 12
    • Views: 14,219
    01-05-2009, 01:24 PM Go to last post
    • Replies: 4
    • Views: 6,404
    01-05-2009, 01:10 PM Go to last post
  5. French Toast

    Started by Michael Greenwalt, 12-31-2008 10:01 AM
    • Replies: 0
    • Views: 4,420
    12-31-2008, 10:01 AM Go to last post
  6. Discolored busbar

    Started by Richard Roshak, 12-29-2008 01:42 PM
    • Replies: 12
    • Views: 11,801
    12-30-2008, 05:26 PM Go to last post
  7. Individual service conductors

    Started by mathew stouffer, 12-29-2008 06:27 PM
    • Replies: 6
    • Views: 4,218
    12-29-2008, 09:34 PM Go to last post
  8. GFCI being used as a switch ???

    Started by Clint White, 12-27-2008 01:03 PM
    • Replies: 30
    • Views: 17,603
    12-29-2008, 03:49 PM Go to last post
  9. double pole breaker shunted?

    Started by Peter Wigle, 07-07-2008 05:17 PM
    • Replies: 25
    • Views: 10,028
    12-26-2008, 05:21 AM Go to last post
  10. Box fill refresher

    Started by Jeff Remas, 12-22-2008 06:35 PM
    • Replies: 6
    • Views: 5,103
    12-23-2008, 07:25 AM Go to last post
  11. New smoke detector law - Texas

    Started by Jim Luttrall, 08-28-2007 03:44 PM
    • Replies: 10
    • Views: 38,081
    12-18-2008, 08:09 PM Go to last post
  12. 14 AWG and 12 AWG wire splicing

    Started by Michael Vasquez, 12-15-2008 03:22 PM
    • Replies: 35
    • Views: 37,130
    12-17-2008, 06:31 PM Go to last post
  13. You make the call AC circuit rating

    Started by Jeff Remas, 12-15-2008 06:20 PM
    • Replies: 10
    • Views: 5,374
    12-16-2008, 05:47 PM Go to last post
    • Replies: 6
    • Views: 13,220
    12-16-2008, 03:00 PM Go to last post
  14. Service Connection

    Started by Stephen G Sheldon, 12-11-2008 10:08 AM
    • Replies: 14
    • Views: 7,737
    12-15-2008, 06:42 AM Go to last post
  15. Service Connection

    Started by Stephen G Sheldon, 12-11-2008 10:05 AM
    • Replies: 23
    • Views: 8,450
    12-14-2008, 10:45 PM Go to last post
  16. 220 breaker from 2 110's?

    Started by Reis Pearson, 12-13-2008 08:27 AM
    • Replies: 4
    • Views: 4,821
    12-13-2008, 09:39 PM Go to last post
  17. Stumped

    Started by Ross Neag, 12-10-2008 08:33 PM
    • Replies: 13
    • Views: 6,299
    12-12-2008, 05:34 PM Go to last post
  18. 120V outlet required in a laundry room?

    Started by Matt Fellman, 12-10-2008 03:44 PM
    • Replies: 22
    • Views: 19,028
    12-12-2008, 12:22 PM Go to last post
  19. main breaker cu/al

    Started by John Arnold, 12-10-2008 10:45 AM
    • Replies: 3
    • Views: 4,889
    12-11-2008, 08:13 AM Go to last post
  20. 2nd Opinion Please on bonding

    Started by Terry Beck, 12-05-2008 05:47 PM
    • Replies: 9
    • Views: 4,975
    12-10-2008, 08:13 PM Go to last post
  21. Lighting Rod Ground wire

    Started by Wendell Swedberg, 12-09-2008 07:36 PM
    • Replies: 7
    • Views: 7,058
    12-10-2008, 01:50 PM Go to last post
  22. ceiling light

    Started by John Arnold, 12-10-2008 01:01 PM
    • Replies: 0
    • Views: 3,655
    12-10-2008, 01:01 PM Go to last post
  23. Nice looking ground connection

    Started by Rick Burkman, 12-05-2008 08:03 PM
    • Replies: 16
    • Views: 7,786
    12-10-2008, 07:18 AM Go to last post
  24. could use a tad more clearance

    Started by John Arnold, 12-08-2008 03:03 PM
    • Replies: 20
    • Views: 7,902
    12-09-2008, 07:13 PM Go to last post
    • Replies: 63
    • Views: 16,997
    12-05-2008, 12:53 PM Go to last post
  25. bedrooms and afci protection

    Started by Matt Fellman, 12-02-2008 11:45 PM
    • Replies: 12
    • Views: 6,741
    12-03-2008, 02:37 PM Go to last post
  26. My county

    Started by Matt Fellman, 10-14-2008 10:09 PM
    • Replies: 19
    • Views: 7,070
    12-03-2008, 07:28 AM Go to last post
  27. E.C Sherman Co. Panel w/FPE breakers

    Started by Ken Amelin, 12-01-2008 03:06 PM
    • Replies: 3
    • Views: 4,188
    12-02-2008, 05:23 AM Go to last post
  28. Grounded and grounding difference?

    Started by Marc M, 11-23-2008 12:39 AM
    • Replies: 34
    • Views: 25,417
    11-28-2008, 04:06 PM Go to last post
  29. Is this ground correct?

    Started by Marc M, 11-26-2008 04:49 PM
    • Replies: 9
    • Views: 6,510
    11-28-2008, 06:32 AM Go to last post
  30. Sub fed from double tap on main lugs

    Started by Jim Ball, 11-21-2008 02:55 PM
    • Replies: 15
    • Views: 13,804
    11-27-2008, 11:33 AM Go to last post
    • Replies: 12
    • Views: 7,728
    11-26-2008, 10:48 PM Go to last post
  31. 2 AFCI questions

    Started by Jim Robinson, 11-15-2008 09:50 AM
    • Replies: 12
    • Views: 9,837
    11-25-2008, 03:24 PM Go to last post
  32. Cool polarity tester

    Started by Paul Johnston, 11-24-2008 04:36 AM
    • Replies: 6
    • Views: 4,870
    11-25-2008, 06:09 AM Go to last post
  33. What is ths?

    Started by Michael Thomas, 11-20-2008 01:27 PM
    • Replies: 9
    • Views: 7,357
    11-21-2008, 09:18 AM Go to last post
  34. why get an inspection?

    Started by Gary Smith, 09-17-2008 04:59 PM
    • Replies: 19
    • Views: 6,553
    11-19-2008, 06:59 PM Go to last post
  35. Receptacles on floor

    Started by Brian Robertson, 11-10-2008 10:04 AM
    • Replies: 17
    • Views: 6,371
    11-19-2008, 04:48 PM Go to last post
  36. Question Bulb to ceiling clearance

    Started by Trent Tarter, 11-02-2008 09:33 PM
    • Replies: 14
    • Views: 15,377
    11-17-2008, 06:09 PM Go to last post
  37. How many things can you find wrong

    Started by Dylan Whitehead, 10-13-2008 11:39 AM
    • Replies: 9
    • Views: 5,220
    11-14-2008, 06:31 AM Go to last post
  38. Water heater switch

    Started by Ken Bates, 11-04-2008 09:55 AM
    • Replies: 10
    • Views: 7,994
    11-05-2008, 06:28 AM Go to last post
  39. what is the amperage for this house

    Started by CHARLIE VAN FLEET, 10-24-2008 01:14 PM
    • Replies: 26
    • Views: 9,787
    11-03-2008, 10:11 PM Go to last post
    • Replies: 4
    • Views: 6,629
    10-31-2008, 10:44 PM Go to last post
  40. Please explain scorched nuetral.

    Started by Marc M, 10-29-2008 07:56 PM
    • Replies: 20
    • Views: 8,033
    10-30-2008, 09:08 PM Go to last post
  41. Help needed understanding panel

    Started by David OKeefe, 10-25-2008 02:26 PM
    • Replies: 31
    • Views: 8,582
    10-28-2008, 07:10 AM Go to last post
  42. Question Need help with sub panel wiring.

    Started by James Edwards, 10-23-2008 04:10 PM
    • Replies: 9
    • Views: 10,377
    10-27-2008, 10:37 AM Go to last post
  43. Are oil lines allowed above electric panel?

    Started by Ken Amelin, 10-23-2008 10:32 AM
    • Replies: 13
    • Views: 7,429
    10-27-2008, 09:08 AM Go to last post
  44. ALUMINUM BRANCH WIRES RETURN

    Started by CHARLIE VAN FLEET, 10-21-2008 02:39 PM
    • Replies: 4
    • Views: 4,430
    10-21-2008, 04:03 PM Go to last post
  45. Need some advice on a project please :)

    Started by Jacob Sanchez, 10-15-2008 08:27 AM
    • Replies: 45
    • Views: 9,751
    10-20-2008, 05:45 PM Go to last post
  46. Question Won't an all AFCI Panel Get HOT !

    Started by Bob Sisson, 10-17-2008 04:52 AM
    • Replies: 6
    • Views: 4,831
    10-18-2008, 06:32 AM Go to last post
  47. How fry up some wires

    Started by mike huntzinger, 10-16-2008 06:07 PM
    • Replies: 9
    • Views: 5,395
    10-17-2008, 08:03 AM Go to last post
  48. Over Amped Panel?

    Started by Matthew Barnicle, 10-15-2008 10:52 AM
    • Replies: 2
    • Views: 4,433
    10-15-2008, 12:41 PM Go to last post
  49. 1957 UPGRADED ELECTRICAL SERVICE

    Started by CHARLIE VAN FLEET, 10-08-2008 07:00 PM
    • Replies: 13
    • Views: 7,438
    10-15-2008, 11:01 AM Go to last post
  50. Splashy Splashy

    Started by Nick Ostrowski, 10-08-2008 06:43 AM
    • Replies: 13
    • Views: 6,522
    10-15-2008, 10:03 AM Go to last post
  51. TV above jet tub

    Started by Dave Hill, 10-14-2008 02:34 PM
    • Replies: 24
    • Views: 14,653
    10-15-2008, 09:44 AM Go to last post
  52. ground rod

    Started by Kevin Rutledge, 09-20-2008 12:46 PM
    • Replies: 6
    • Views: 5,458
    10-15-2008, 08:57 AM Go to last post
  53. Voltage on grounding cable

    Started by Brian Robertson, 09-09-2008 11:39 AM
    • Replies: 17
    • Views: 6,275
    10-15-2008, 08:37 AM Go to last post
    • Replies: 6
    • Views: 4,817
    10-14-2008, 02:39 PM Go to last post
  54. FPE Stab-Lok double lugged 100-amp

    Started by Grant Harrod, 10-09-2008 10:32 PM
    • Replies: 0
    • Views: 5,538
    10-09-2008, 10:32 PM Go to last post
  55. GFCI outlet at jacuzzi tub

    Started by Jody Humbert, 10-01-2008 10:39 AM
    • Replies: 7
    • Views: 13,017
    10-02-2008, 10:04 AM Go to last post
  56. Honey where are my Shocks, I mean socks

    Started by wayne soper, 10-01-2008 09:38 AM
    • Replies: 2
    • Views: 4,239
    10-02-2008, 10:01 AM Go to last post
  57. Exclamation GFCI (kitchen/bath) - Max # of branch

    Started by Robert Alexander, 09-20-2008 06:01 AM
    • Replies: 36
    • Views: 12,787
    09-30-2008, 05:29 PM Go to last post
    • Replies: 12
    • Views: 11,784
    09-26-2008, 06:33 PM Go to last post
  58. How does does this happen?

    Started by Marc M, 09-24-2008 09:09 PM
    • Replies: 1
    • Views: 4,319
    09-26-2008, 05:03 PM Go to last post
  59. 12 awg and 15 amp breaker-is this just overkill?

    Started by Marc M, 09-19-2008 07:28 PM
    • Replies: 23
    • Views: 25,628
    09-26-2008, 04:49 PM Go to last post
    • Replies: 0
    • Views: 4,828
    09-26-2008, 06:55 AM Go to last post
  60. Best knob and tube trick yet

    Started by Michael Thomas, 09-22-2008 03:46 PM
    • Replies: 1
    • Views: 4,693
    09-22-2008, 04:13 PM Go to last post
  61. Service Riser/Lateral

    Started by Dan Blanchard, 09-21-2008 01:57 PM
    • Replies: 7
    • Views: 6,263
    09-22-2008, 08:19 AM Go to last post
  62. Fixture/bath tub clearence

    Started by Steven Turetsky, 05-30-2008 11:25 PM
    • Replies: 12
    • Views: 5,729
    09-19-2008, 05:40 PM Go to last post
  63. Question 240 volt double pole breakers

    Started by Trent Tarter, 09-18-2008 10:25 PM
    • Replies: 7
    • Views: 8,471
    09-19-2008, 12:44 PM Go to last post
  64. Them copper wires

    Started by MaMa Mount, 09-17-2008 11:31 AM
    • Replies: 11
    • Views: 5,666
    09-19-2008, 06:21 AM Go to last post
    • Replies: 1
    • Views: 6,120
    09-18-2008, 10:16 AM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •