1. 04-16-2007
    Views:
    116,559

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. 240 only distribution panel?

    Started by Oni Shaw, 06-01-2016 08:21 PM
    • Replies: 8
    • Views: 1,862
    06-13-2016, 05:20 AM Go to last post
    • Replies: 0
    • Views: 939
    06-07-2016, 05:05 AM Go to last post
  2. Remote panel in remote building

    Started by Ken Amelin, 05-25-2016 05:39 AM
    • Replies: 5
    • Views: 1,781
    05-27-2016, 09:16 PM Go to last post
  3. Unfamiliar break.

    Started by ROBERT YOUNG, 05-21-2016 02:24 PM
    • Replies: 3
    • Views: 1,582
    05-21-2016, 07:21 PM Go to last post
  4. Remote panel rating question.

    Started by ROBERT YOUNG, 05-15-2016 08:26 AM
    • Replies: 4
    • Views: 1,743
    05-15-2016, 04:56 PM Go to last post
  5. HUD inspections

    Started by Robert Garza, 05-14-2016 09:43 AM
    • Replies: 0
    • Views: 806
    05-14-2016, 09:43 AM Go to last post
  6. Newb in need

    Started by Aaron Scheuerer, 05-13-2016 10:28 AM
    • Replies: 6
    • Views: 1,610
    05-13-2016, 11:04 PM Go to last post
    • Replies: 1
    • Views: 1,265
    05-12-2016, 05:48 PM Go to last post
    • Replies: 13
    • Views: 3,733
    05-12-2016, 01:28 PM Go to last post
  7. CA Electrical Code source?

    Started by Connor Akally, 05-09-2016 07:00 AM
    code, copy, electrical, electronic, pdf
    • Replies: 7
    • Views: 3,385
    05-09-2016, 02:42 PM Go to last post
  8. breakers trip each other

    Started by Peter Louis, 04-28-2016 05:37 PM
    • Replies: 34
    • Views: 4,574
    05-09-2016, 05:48 AM Go to last post
    • Replies: 12
    • Views: 4,502
    05-08-2016, 09:25 AM Go to last post
  9. Over- amped panel...

    Started by Chris Weekly, 05-06-2016 08:25 PM
    • Replies: 3
    • Views: 1,928
    05-07-2016, 08:36 AM Go to last post
  10. 110V Service ?

    Started by Ken Rowe, 04-21-2016 10:35 AM
    • Replies: 33
    • Views: 9,381
    04-25-2016, 12:54 PM Go to last post
  11. Drop voltage

    Started by ROBERT YOUNG, 04-19-2016 05:34 AM
    • Replies: 30
    • Views: 3,112
    04-21-2016, 01:34 PM Go to last post
  12. Question Bonded Neutrals???

    Started by Jeff Gainey, 04-17-2016 09:15 AM
    • Replies: 14
    • Views: 2,042
    04-19-2016, 07:33 PM Go to last post
  13. Double Tap for Surge Protector

    Started by Eldon (Scooter) Holliday, 06-11-2011 03:23 PM
    • Replies: 30
    • Views: 12,970
    04-12-2016, 06:41 AM Go to last post
    • Replies: 3
    • Views: 1,700
    04-11-2016, 07:48 PM Go to last post
  14. copper and natural gas

    Started by Don Hawley, 04-10-2016 07:28 AM
    copper, gas, natural, natural gas, safety issue
    • Replies: 3
    • Views: 1,603
    04-11-2016, 12:24 PM Go to last post
  15. Color coding fiasco

    Started by Chris Weekly, 04-06-2016 01:36 PM
    • Replies: 31
    • Views: 3,578
    04-10-2016, 10:21 AM Go to last post
  16. Sub Panel Ground

    Started by ROBERT YOUNG, 03-24-2016 08:53 AM
    • Replies: 16
    • Views: 3,772
    04-09-2016, 08:25 PM Go to last post
  17. Unsheathed Branch circuit wires.

    Started by Ken Amelin, 03-24-2016 09:31 AM
    • Replies: 16
    • Views: 3,245
    04-09-2016, 07:35 PM Go to last post
  18. Electrical panel painted closed

    Started by Vern Heiler, 04-03-2016 08:33 AM
    considered, functioning, intended, painted, panel
    • Replies: 30
    • Views: 3,517
    04-09-2016, 08:22 AM Go to last post
  19. 60 or 90 - choose

    Started by Chris Weekly, 04-06-2016 01:42 PM
    • Replies: 7
    • Views: 1,851
    04-08-2016, 10:58 PM Go to last post
  20. Remote Load Center

    Started by ROBERT YOUNG, 04-03-2016 03:07 AM
    • Replies: 10
    • Views: 2,007
    04-04-2016, 07:18 AM Go to last post
  21. Low voltage light power

    Started by Jim Luttrall, 03-28-2016 06:14 PM
    • Replies: 5
    • Views: 1,683
    04-01-2016, 05:51 PM Go to last post
  22. Two Main Breakers

    Started by Pete Kosmoski, 03-22-2016 01:14 PM
    amp, electrical, front, main, two main breakers
    • Replies: 9
    • Views: 3,785
    03-24-2016, 07:44 AM Go to last post
  23. Question Imbedded Meter Base

    Started by Jeff Gainey, 03-15-2016 06:28 PM
    • Replies: 14
    • Views: 2,676
    03-21-2016, 04:48 PM Go to last post
    • Replies: 26
    • Views: 4,617
    03-11-2016, 08:13 AM Go to last post
  24. Taylor Electric or Crouse-Hinds Panels

    Started by ROBERT YOUNG, 02-26-2016 02:55 PM
    • Replies: 2
    • Views: 2,813
    03-09-2016, 11:17 PM Go to last post
  25. Information required

    Started by ROBERT YOUNG, 03-07-2016 07:00 PM
    • Replies: 2
    • Views: 1,521
    03-08-2016, 04:12 AM Go to last post
  26. Ufer ground

    Started by ROBERT YOUNG, 02-25-2016 04:35 AM
    • Replies: 8
    • Views: 2,055
    02-26-2016, 08:17 PM Go to last post
  27. Grounds & Neutral on same bus bar

    Started by Sam Morris, 02-23-2016 06:21 PM
    • Replies: 10
    • Views: 5,815
    02-24-2016, 05:04 PM Go to last post
  28. mechanical disconnect switch

    Started by ROBERT YOUNG, 02-21-2016 05:31 PM
    • Replies: 2
    • Views: 2,187
    02-22-2016, 12:59 PM Go to last post
  29. Commander breaker in a Sylvania panel

    Started by ROBERT YOUNG, 02-14-2016 04:34 AM
    • Replies: 2
    • Views: 2,104
    02-17-2016, 05:35 AM Go to last post
    • Replies: 12
    • Views: 7,036
    02-14-2016, 07:02 AM Go to last post
  30. Grounding, Bonding, and Earthing

    Started by Frederick Leutzinger, 02-03-2016 10:44 PM
    copper, grounding, learning, nec, post
    • Replies: 8
    • Views: 3,449
    02-08-2016, 10:29 PM Go to last post
  31. Controller Cabinet Power Circuit

    Started by GaryOdom, 02-04-2016 06:56 AM
    bottom, circuit, power, supply, wired
    • Replies: 2
    • Views: 1,569
    02-08-2016, 10:23 PM Go to last post
  32. Dishwasher service disconnect (NEC 422)

    Started by Dave Hahn, 01-08-2009 12:48 AM
    • Replies: 29
    • Views: 25,821
    02-08-2016, 03:33 PM Go to last post
  33. Lightning arrestor grounded to water line

    Started by Roger Kautz, 01-10-2016 08:29 PM
    • Replies: 11
    • Views: 3,178
    02-04-2016, 08:09 PM Go to last post
  34. No Need To Worry

    Started by Jim Robinson, 02-02-2016 09:23 PM
    • Replies: 0
    • Views: 1,184
    02-02-2016, 09:23 PM Go to last post
  35. Homemade Generator Transfer Switch

    Started by Raymond Wand, 01-04-2016 02:04 PM
    • Replies: 34
    • Views: 7,818
    01-23-2016, 03:35 PM Go to last post
  36. Hillbilly Junction Box

    Started by Tab Wilcox, 12-21-2015 08:08 AM
    • Replies: 13
    • Views: 3,523
    01-03-2016, 07:46 AM Go to last post
  37. outlet tester results

    Started by Norm Peery, 12-11-2015 08:44 AM
    • Replies: 3
    • Views: 1,642
    12-25-2015, 06:01 AM Go to last post
  38. When a junction box just won't do...

    Started by Bruce Ramsey, 06-03-2013 07:53 PM
    • Replies: 4
    • Views: 3,144
    12-24-2015, 10:31 PM Go to last post
  39. Distribution panel wiring

    Started by Russell Melville, 12-04-2015 10:48 AM
    • Replies: 4
    • Views: 2,608
    12-20-2015, 10:53 AM Go to last post
  40. main disconnect

    Started by ROBERT YOUNG, 12-14-2015 10:26 PM
    • Replies: 4
    • Views: 1,954
    12-15-2015, 12:08 PM Go to last post
  41. Hydro Service Entrance

    Started by ROBERT YOUNG, 11-22-2015 05:29 PM
    • Replies: 6
    • Views: 2,800
    12-03-2015, 05:27 PM Go to last post
  42. DUMB SERVICE PANEL COVER

    Started by CHARLIE VAN FLEET, 11-12-2015 08:01 AM
    • Replies: 13
    • Views: 4,135
    11-21-2015, 08:29 AM Go to last post
  43. Pool fence bonding

    Started by Bill Bryan, 11-19-2015 01:32 PM
    bonded, fence, minutes, pool, told
    • Replies: 2
    • Views: 3,216
    11-20-2015, 10:14 PM Go to last post
  44. Parallel Wiring

    Started by Jim Robinson, 11-05-2015 01:26 PM
    added, amp, electric, kitchen, wires
    • Replies: 4
    • Views: 1,999
    11-15-2015, 11:47 AM Go to last post
  45. Main panel

    Started by Russell Melville, 11-07-2015 05:30 PM
    • Replies: 14
    • Views: 4,500
    11-14-2015, 11:09 AM Go to last post
  46. Metal raceway as support for pool J box

    Started by Marc M, 11-07-2015 05:16 PM
    • Replies: 7
    • Views: 2,286
    11-08-2015, 07:54 PM Go to last post
  47. Transition from Type NM to NM-B wiring

    Started by Hank Spinnler, 09-22-2011 07:16 PM
    • Replies: 5
    • Views: 19,325
    11-05-2015, 11:14 AM Go to last post
  48. Split Bus Wiring

    Started by Nick Ostrowski, 11-03-2015 01:21 PM
    • Replies: 7
    • Views: 2,901
    11-04-2015, 10:44 AM Go to last post
  49. Lightening Collector?

    Started by Michael Chambers, 11-03-2015 10:43 AM
    • Replies: 6
    • Views: 1,687
    11-03-2015, 03:48 PM Go to last post
  50. Electric Ground Hot to the Touch

    Started by Larry Heitzenrater, 10-29-2015 05:00 PM
    ground, ground rod, hot to touch, panel, rod
    • Replies: 10
    • Views: 3,153
    10-30-2015, 10:58 AM Go to last post
  51. ungrounded sub panel

    Started by Don Hawley, 10-22-2015 07:26 PM
    ground, grounds, panel, separate, wire
    • Replies: 13
    • Views: 4,323
    10-30-2015, 06:51 AM Go to last post
  52. Question Do I need 400 amp service?

    Started by Mark Spohr, 10-24-2015 11:12 AM
    amp, electric load, garage, panels, service
    • Replies: 6
    • Views: 5,019
    10-29-2015, 05:26 PM Go to last post
  53. 60 amp main breaker as main on 150 service

    Started by mark petty, 10-21-2015 02:37 PM
    • Replies: 9
    • Views: 2,453
    10-28-2015, 10:05 PM Go to last post
  54. AFCI Outlet Device

    Started by Gunnar Alquist, 10-13-2015 04:58 PM
    • Replies: 19
    • Views: 3,454
    10-25-2015, 09:06 AM Go to last post
  55. How do you fix "double Taps"?

    Started by Gerry Bennett, 10-06-2015 03:03 PM
    breaker, breakers, double, panel, taps
    • Replies: 17
    • Views: 8,575
    10-23-2015, 03:35 AM Go to last post
    • Replies: 63
    • Views: 16,023
    10-14-2015, 05:46 PM Go to last post
  56. Bundling in panel board

    Started by Joe Hendrix, 09-30-2015 02:25 PM
    • Replies: 15
    • Views: 3,105
    10-08-2015, 06:18 PM Go to last post
    • Replies: 7
    • Views: 2,364
    10-07-2015, 05:35 PM Go to last post
  57. No GFCI receptacles or breakers?

    Started by Donald Farrell, 09-25-2015 10:38 AM
    amp, circuits, home, protected, receptacles
    • Replies: 34
    • Views: 4,382
    10-06-2015, 09:24 AM Go to last post
    • Replies: 6
    • Views: 2,269
    10-06-2015, 06:02 AM Go to last post
  58. Unprotected NM, how high?

    Started by Benjamin Thompson, 10-20-2011 01:04 AM
    • Replies: 17
    • Views: 6,693
    10-01-2015, 08:23 AM Go to last post
    • Replies: 6
    • Views: 2,293
    09-28-2015, 02:11 PM Go to last post
    • Replies: 11
    • Views: 19,133
    09-23-2015, 06:31 PM Go to last post
  59. Slash Rated Breakers

    Started by Derek Guridi, 09-22-2015 09:44 AM
    • Replies: 0
    • Views: 2,948
    09-22-2015, 09:44 AM Go to last post
  60. Handle Ties

    Started by Richard Robinson, 09-11-2015 07:01 AM
    • Replies: 62
    • Views: 10,576
    09-20-2015, 11:00 AM Go to last post
  61. Service wire installation concerns

    Started by Richard Roshak, 09-02-2015 12:57 PM
    • Replies: 6
    • Views: 2,426
    09-16-2015, 09:00 PM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •