1. 04-16-2007
    Views:
    1,989,496

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. Hello everyone

    Started by George Eberle, 02-13-2017 10:00 AM
    george, post, power, shortly, thread
    • Replies: 0
    • Views: 3,232
    02-13-2017, 10:00 AM Go to last post
    • Replies: 5
    • Views: 4,475
    02-05-2017, 01:12 PM Go to last post
  2. electrical narrative required

    Started by ROBERT YOUNG, 02-01-2017 06:21 PM
    • Replies: 4
    • Views: 4,715
    02-02-2017, 04:32 AM Go to last post
  3. receptacle type

    Started by John Dirks Jr, 01-30-2017 06:14 AM
    • Replies: 3
    • Views: 3,743
    01-30-2017, 07:11 AM Go to last post
  4. is this improper grounding/bonding

    Started by Don Hawley, 01-26-2017 08:44 PM
    • Replies: 22
    • Views: 7,798
    01-27-2017, 07:43 PM Go to last post
    • Replies: 22
    • Views: 19,375
    01-26-2017, 06:33 PM Go to last post
  5. SEC splice

    Started by John Dirks Jr, 01-22-2017 06:20 PM
    • Replies: 43
    • Views: 9,675
    01-26-2017, 10:59 AM Go to last post
  6. wire size to compensate for voltage drop

    Started by Jack Feldmann, 12-22-2016 06:22 PM
    load, run, size, thought, wire
    • Replies: 12
    • Views: 10,671
    01-26-2017, 04:58 AM Go to last post
  7. Scorched/damaged grounding conductor

    Started by Robert Foster, 11-16-2016 04:58 PM
    • Replies: 2
    • Views: 4,850
    01-20-2017, 07:58 AM Go to last post
  8. EGC question

    Started by ROBERT YOUNG, 12-29-2016 12:13 PM
    acceptable, considered, egc, spray, styrofoam
    • Replies: 17
    • Views: 9,407
    01-11-2017, 04:51 PM Go to last post
  9. Improper multi-wire circuit??

    Started by Terry Beck, 12-13-2016 12:54 AM
    • Replies: 27
    • Views: 10,690
    12-17-2016, 10:17 AM Go to last post
  10. Wth is this ?!?

    Started by Aaron Scheuerer, 11-16-2016 04:23 PM
    • Replies: 11
    • Views: 6,585
    12-17-2016, 08:09 AM Go to last post
  11. Question exposed romex

    Started by Robert Gaspy, 11-17-2016 06:51 AM
    • Replies: 9
    • Views: 12,071
    11-30-2016, 09:15 PM Go to last post
  12. What panel is this!

    Started by adamjohn, 11-30-2016 02:26 AM
    • Replies: 1
    • Views: 4,123
    11-30-2016, 02:46 AM Go to last post
  13. Require help with a narrative.

    Started by ROBERT YOUNG, 11-13-2016 04:48 PM
    • Replies: 21
    • Views: 8,057
    11-16-2016, 11:11 PM Go to last post
  14. Require a narrative.

    Started by ROBERT YOUNG, 11-10-2016 04:37 AM
    • Replies: 15
    • Views: 7,629
    11-16-2016, 01:54 PM Go to last post
  15. service panel question

    Started by ROBERT YOUNG, 10-31-2016 03:08 PM
    • Replies: 10
    • Views: 5,686
    11-09-2016, 07:57 AM Go to last post
    • Replies: 5
    • Views: 4,830
    11-07-2016, 07:25 PM Go to last post
  16. Question Tester Tripping AFCI's

    Started by Michael Chambers, 11-03-2016 10:01 PM
    • Replies: 7
    • Views: 4,507
    11-04-2016, 09:27 PM Go to last post
  17. New issue with AFCI breakers tripping

    Started by Eric S, 09-01-2014 03:28 PM
    • Replies: 10
    • Views: 5,643
    11-03-2016, 09:33 PM Go to last post
  18. Neutral bus question.

    Started by ROBERT YOUNG, 10-22-2016 03:52 PM
    • Replies: 16
    • Views: 6,492
    10-31-2016, 06:45 AM Go to last post
  19. AKA Sub-Panel ground wire jumper

    Started by Sam Morris, 10-18-2016 05:20 PM
    • Replies: 12
    • Views: 7,293
    10-28-2016, 04:24 AM Go to last post
    • Replies: 1
    • Views: 4,246
    10-26-2016, 05:53 PM Go to last post
    • Replies: 7
    • Views: 6,589
    10-23-2016, 09:42 AM Go to last post
  20. Grounding electrode - DWV piping

    Started by Ken Amelin, 10-20-2016 06:50 AM
    • Replies: 29
    • Views: 9,706
    10-23-2016, 06:20 AM Go to last post
  21. Splices and Double tapped Service Drop

    Started by Lawrence Thomas, 10-04-2016 05:37 PM
    • Replies: 19
    • Views: 6,665
    10-21-2016, 04:44 PM Go to last post
  22. Require help to answer a question.

    Started by ROBERT YOUNG, 08-05-2016 09:09 PM
    • Replies: 16
    • Views: 7,666
    10-11-2016, 07:59 AM Go to last post
  23. GFCI circuit question

    Started by ROBERT YOUNG, 09-26-2016 09:22 AM
    • Replies: 49
    • Views: 14,028
    10-11-2016, 07:41 AM Go to last post
  24. 60's home with low voltage switching

    Started by Alton Darty, 10-04-2016 04:32 AM
    • Replies: 3
    • Views: 4,065
    10-11-2016, 07:04 AM Go to last post
  25. Upside down receptacles

    Started by JIM MURPHY, 08-25-2016 03:05 PM
    • Replies: 61
    • Views: 22,042
    10-09-2016, 05:24 PM Go to last post
  26. Low Weatherhead

    Started by Rick Bunzel, 09-17-2016 01:40 PM
    • Replies: 9
    • Views: 6,212
    10-06-2016, 10:42 AM Go to last post
  27. Dual water heaters

    Started by David Lyons, 09-24-2016 05:09 PM
    • Replies: 4
    • Views: 4,359
    10-06-2016, 09:00 AM Go to last post
  28. Code citation regarding split bus panel

    Started by Mark Reinmiller, 09-21-2016 01:08 PM
    areas, bus, code, find, split
    • Replies: 5
    • Views: 7,281
    10-06-2016, 08:55 AM Go to last post
  29. main disconnect question.

    Started by ROBERT YOUNG, 09-05-2016 04:51 PM
    • Replies: 12
    • Views: 5,859
    09-16-2016, 10:28 PM Go to last post
  30. Panel - balanced load

    Started by Ken Amelin, 08-31-2016 05:58 AM
    • Replies: 16
    • Views: 9,228
    09-05-2016, 11:12 AM Go to last post
  31. Panel type

    Started by ROBERT YOUNG, 09-03-2016 04:45 PM
    • Replies: 1
    • Views: 3,186
    09-04-2016, 04:45 AM Go to last post
    • Replies: 25
    • Views: 10,259
    09-02-2016, 02:12 PM Go to last post
  32. When is IGB required?

    Started by Jim Robinson, 08-23-2016 06:10 PM
    • Replies: 20
    • Views: 10,342
    08-26-2016, 10:41 AM Go to last post
    • Replies: 17
    • Views: 8,855
    08-25-2016, 06:59 AM Go to last post
  33. Electrical Feed

    Started by Mike Tracy, 08-22-2016 01:02 PM
    aluminum, connected, copper, feed, wire
    • Replies: 1
    • Views: 4,053
    08-22-2016, 09:47 PM Go to last post
    • Replies: 14
    • Views: 8,350
    08-20-2016, 07:09 AM Go to last post
  34. Bundled Neutrals!

    Started by Donald Farrell, 08-01-2016 07:41 AM
    amp, branch, circuits, fed, recepts
    • Replies: 13
    • Views: 7,100
    08-02-2016, 11:37 AM Go to last post
    • Replies: 2
    • Views: 3,996
    08-02-2016, 03:04 AM Go to last post
  35. 20 receptacle connection

    Started by Ken Amelin, 01-17-2009 12:54 PM
    • Replies: 56
    • Views: 17,521
    07-23-2016, 06:18 PM Go to last post
  36. New To Me

    Started by Jim Robinson, 07-15-2016 05:12 PM
    • Replies: 16
    • Views: 7,906
    07-22-2016, 04:29 AM Go to last post
  37. How many main panels can one condo have?

    Started by Tom King, 07-06-2016 09:20 PM
    • Replies: 18
    • Views: 8,452
    07-09-2016, 01:20 PM Go to last post
  38. Bonding and grounding requirements.

    Started by ROBERT YOUNG, 07-04-2016 04:43 AM
    • Replies: 1
    • Views: 4,331
    07-04-2016, 11:12 PM Go to last post
  39. This is fine....

    Started by Marc M, 06-23-2016 07:41 AM
    • Replies: 37
    • Views: 11,978
    07-04-2016, 06:43 PM Go to last post
  40. panel & hose connection

    Started by Jeff Zehnder, 06-30-2016 05:19 AM
    • Replies: 8
    • Views: 5,170
    07-02-2016, 03:15 PM Go to last post
  41. Service wires overhang roof

    Started by Sam Morris, 06-30-2016 03:28 PM
    • Replies: 4
    • Views: 4,342
    07-01-2016, 03:23 PM Go to last post
  42. distribution panel questions

    Started by Russell Melville, 06-14-2016 12:54 PM
    • Replies: 4
    • Views: 4,917
    06-18-2016, 07:05 PM Go to last post
  43. GFCI but no Ground

    Started by Jim Robinson, 06-16-2016 01:23 PM
    • Replies: 15
    • Views: 9,009
    06-18-2016, 10:47 AM Go to last post
  44. 240 only distribution panel?

    Started by Oni Shaw, 06-01-2016 08:21 PM
    • Replies: 8
    • Views: 5,425
    06-13-2016, 05:20 AM Go to last post
    • Replies: 0
    • Views: 2,883
    06-07-2016, 05:05 AM Go to last post
  45. Remote panel in remote building

    Started by Ken Amelin, 05-25-2016 05:39 AM
    • Replies: 5
    • Views: 4,610
    05-27-2016, 09:16 PM Go to last post
  46. Unfamiliar break.

    Started by ROBERT YOUNG, 05-21-2016 02:24 PM
    • Replies: 3
    • Views: 3,780
    05-21-2016, 07:21 PM Go to last post
  47. Remote panel rating question.

    Started by ROBERT YOUNG, 05-15-2016 08:26 AM
    • Replies: 4
    • Views: 4,220
    05-15-2016, 04:56 PM Go to last post
  48. HUD inspections

    Started by Robert Garza, 05-14-2016 09:43 AM
    • Replies: 0
    • Views: 2,638
    05-14-2016, 09:43 AM Go to last post
  49. Newb in need

    Started by Aaron Scheuerer, 05-13-2016 10:28 AM
    • Replies: 6
    • Views: 4,257
    05-13-2016, 11:04 PM Go to last post
    • Replies: 1
    • Views: 3,877
    05-12-2016, 05:48 PM Go to last post
    • Replies: 13
    • Views: 8,410
    05-12-2016, 01:28 PM Go to last post
  50. CA Electrical Code source?

    Started by Connor Akally, 05-09-2016 07:00 AM
    code, copy, electrical, electronic, pdf
    • Replies: 7
    • Views: 7,429
    05-09-2016, 02:42 PM Go to last post
  51. breakers trip each other

    Started by Peter Louis, 04-28-2016 05:37 PM
    • Replies: 34
    • Views: 11,403
    05-09-2016, 05:48 AM Go to last post
    • Replies: 12
    • Views: 10,131
    05-08-2016, 09:25 AM Go to last post
  52. Over- amped panel...

    Started by Chris Weekly, 05-06-2016 08:25 PM
    • Replies: 3
    • Views: 4,706
    05-07-2016, 08:36 AM Go to last post
  53. 110V Service ?

    Started by Ken Rowe, 04-21-2016 10:35 AM
    • Replies: 33
    • Views: 16,098
    04-25-2016, 12:54 PM Go to last post
  54. Drop voltage

    Started by ROBERT YOUNG, 04-19-2016 05:34 AM
    • Replies: 30
    • Views: 8,709
    04-21-2016, 01:34 PM Go to last post
  55. Question Bonded Neutrals???

    Started by Jeff Gainey, 04-17-2016 09:15 AM
    • Replies: 14
    • Views: 5,442
    04-19-2016, 07:33 PM Go to last post
  56. Double Tap for Surge Protector

    Started by Eldon (Scooter) Holliday, 06-11-2011 03:23 PM
    • Replies: 30
    • Views: 23,278
    04-12-2016, 06:41 AM Go to last post
    • Replies: 3
    • Views: 4,107
    04-11-2016, 07:48 PM Go to last post
  57. copper and natural gas

    Started by Don Hawley, 04-10-2016 07:28 AM
    copper, gas, natural, natural gas, safety issue
    • Replies: 3
    • Views: 4,615
    04-11-2016, 12:24 PM Go to last post
  58. Color coding fiasco

    Started by Chris Weekly, 04-06-2016 01:36 PM
    • Replies: 31
    • Views: 8,523
    04-10-2016, 10:21 AM Go to last post
  59. Sub Panel Ground

    Started by ROBERT YOUNG, 03-24-2016 08:53 AM
    • Replies: 16
    • Views: 7,104
    04-09-2016, 08:25 PM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •