1. 04-16-2007
    Views:
    105,464

Forum: Electrical Systems: Home Inspection and Commercial Inspection

Service Conductors, Panels, Overcurrent Protection Devices, Wiring Types and Methods, Switches, Receptacles, Light Fixtures ... For Home Inspections & Commercial Inspections

  1. GEC splice in panel

    Started by brianmiller, 12-04-2013 08:40 PM
    • Replies: 2
    • Views: 1,402
    01-14-2014, 03:59 AM Go to last post
  2. Nasty surprise

    Started by john stone, 01-13-2014 01:42 PM
    • Replies: 4
    • Views: 1,398
    01-13-2014, 07:27 PM Go to last post
  3. Frankenstein's electrical panel?

    Started by Welmoed Sisson, 08-20-2012 04:53 PM
    2 Pages
    1 2
    • Replies: 112
    • Views: 12,700
    01-08-2014, 11:13 AM Go to last post
  4. Old panel?

    Started by Josh Drake, 12-11-2013 03:11 PM
    • Replies: 9
    • Views: 2,552
    12-29-2013, 03:57 PM Go to last post
  5. Combining two 120v circuits

    Started by John Kogel, 12-13-2013 08:40 AM
    • Replies: 9
    • Views: 2,902
    12-14-2013, 09:40 PM Go to last post
  6. House wiring in Florida.

    Started by Stephen Silva, 12-03-2013 09:21 AM
    • Replies: 39
    • Views: 3,056
    12-14-2013, 12:22 PM Go to last post
  7. Conduit Sizing

    Started by Bruce Ramsey, 12-04-2013 06:55 PM
    • Replies: 10
    • Views: 1,939
    12-08-2013, 03:22 PM Go to last post
  8. AFCI Question

    Started by Chris Stichter, 12-03-2013 07:11 PM
    • Replies: 7
    • Views: 1,675
    12-04-2013, 12:41 PM Go to last post
  9. Number of Spares in New Service Installation

    Started by Rich Goeken, 12-01-2013 07:36 AM
    • Replies: 1
    • Views: 1,240
    12-01-2013, 12:33 PM Go to last post
  10. Gfci trips on test but reset button is frozen?

    Started by JP Lomeo, 11-19-2013 04:56 PM
    • Replies: 18
    • Views: 9,847
    11-28-2013, 01:48 AM Go to last post
  11. Smoke detectors on AFB protected circuit

    Started by Ernie Simpson, 11-25-2013 09:08 PM
    • Replies: 2
    • Views: 1,194
    11-26-2013, 06:30 AM Go to last post
  12. Bootlegged power?

    Started by Oni Shaw, 11-24-2013 12:25 PM
    • Replies: 8
    • Views: 1,856
    11-25-2013, 07:32 AM Go to last post
  13. This can't be right

    Started by Richard Roshak, 11-24-2013 01:03 PM
    • Replies: 2
    • Views: 1,313
    11-24-2013, 04:27 PM Go to last post
  14. Seeing is believing

    Started by Richard Roshak, 11-24-2013 01:05 PM
    • Replies: 2
    • Views: 1,380
    11-24-2013, 03:05 PM Go to last post
    • Replies: 8
    • Views: 2,134
    11-23-2013, 12:20 PM Go to last post
  15. Min/Max receptacle height above floor?

    Started by Bruce Ramsey, 11-16-2013 05:03 PM
    • Replies: 15
    • Views: 37,989
    11-19-2013, 10:07 AM Go to last post
  16. neutral terminal

    Started by Jim Robinson, 11-09-2013 10:36 AM
    • Replies: 21
    • Views: 2,490
    11-18-2013, 07:06 PM Go to last post
  17. Wet or Damp?

    Started by Jerry McCarthy, 01-07-2008 02:26 PM
    • Replies: 27
    • Views: 13,568
    11-12-2013, 08:29 PM Go to last post
  18. Soldered Romex

    Started by Ken Rowe, 10-18-2013 09:59 PM
    • Replies: 52
    • Views: 8,359
    11-07-2013, 06:38 PM Go to last post
    • Replies: 11
    • Views: 2,999
    11-06-2013, 07:40 PM Go to last post
    • Replies: 3
    • Views: 1,419
    11-06-2013, 11:25 AM Go to last post
  19. Conflict with a licensed electrician

    Started by Ken Amelin, 09-16-2013 02:07 PM
    • Replies: 34
    • Views: 4,566
    11-01-2013, 08:39 AM Go to last post
    • Replies: 3
    • Views: 3,204
    10-31-2013, 09:40 AM Go to last post
    • Replies: 5
    • Views: 2,059
    10-30-2013, 05:07 AM Go to last post
    • Replies: 2
    • Views: 2,874
    10-28-2013, 06:05 PM Go to last post
  20. Condo panel question

    Started by Welmoed Sisson, 10-25-2013 05:41 AM
    • Replies: 5
    • Views: 5,000
    10-27-2013, 10:16 AM Go to last post
    • Replies: 4
    • Views: 1,770
    10-25-2013, 06:12 PM Go to last post
  21. More than one GFI on the same circuit

    Started by Frank Bombardiere, 04-30-2010 05:55 PM
    • Replies: 58
    • Views: 63,308
    10-22-2013, 07:29 AM Go to last post
  22. Neutral Bus in Separate J-Box

    Started by Mike Lamb, 10-12-2013 02:41 PM
    • Replies: 3
    • Views: 1,678
    10-17-2013, 02:56 PM Go to last post
  23. "Sub Panel" Connections

    Started by Ken Amelin, 10-16-2013 06:12 AM
    • Replies: 6
    • Views: 1,854
    10-17-2013, 07:37 AM Go to last post
  24. Breaker Link Material

    Started by Ken Amelin, 10-13-2013 05:33 AM
    • Replies: 11
    • Views: 2,174
    10-17-2013, 01:12 AM Go to last post
  25. Bunching Romex

    Started by Lawrence Thomas, 11-04-2011 05:22 PM
    2 Pages
    1 2
    • Replies: 128
    • Views: 33,637
    10-10-2013, 05:59 PM Go to last post
  26. Derating wire

    Started by Erik Pendleton, 10-06-2013 02:18 PM
    • Replies: 5
    • Views: 3,146
    10-08-2013, 08:13 AM Go to last post
  27. Bundling?

    Started by Marc M, 05-15-2012 10:59 PM
    • Replies: 14
    • Views: 2,846
    10-08-2013, 08:12 AM Go to last post
  28. ? for electrical experts-Class NI

    Started by Mark Reinmiller, 09-30-2013 05:05 PM
    • Replies: 4
    • Views: 2,840
    10-02-2013, 06:33 PM Go to last post
  29. Strange switches in 1958 home

    Started by John Arnold, 09-27-2013 12:03 PM
    • Replies: 5
    • Views: 1,744
    09-27-2013, 04:32 PM Go to last post
  30. Square D panel

    Started by Russell Melville, 09-04-2013 06:21 PM
    • Replies: 28
    • Views: 5,469
    09-23-2013, 05:46 PM Go to last post
  31. Question Outdated wiring in condo unit

    Started by Welmoed Sisson, 09-17-2013 12:48 PM
    • Replies: 17
    • Views: 5,468
    09-23-2013, 06:01 AM Go to last post
  32. Double Tap and Bundling Madness

    Started by Nick Ostrowski, 09-17-2013 06:46 AM
    • Replies: 16
    • Views: 4,004
    09-21-2013, 09:48 AM Go to last post
    • Replies: 32
    • Views: 17,339
    09-21-2013, 07:12 AM Go to last post
  33. Monitoring usage through circuits, "metering"

    Started by Matt Fellman, 09-15-2013 10:19 PM
    • Replies: 6
    • Views: 1,969
    09-16-2013, 02:49 PM Go to last post
    • Replies: 2
    • Views: 2,409
    09-15-2013, 06:06 PM Go to last post
  34. Service drop and disconnect (pull tab)

    Started by mathew stouffer, 05-23-2013 09:10 PM
    • Replies: 6
    • Views: 3,012
    09-14-2013, 09:48 AM Go to last post
  35. Determining the amperage mat a main disconnect fuse block

    Started by Scott Bray, 08-01-2013 10:02 AM
    5 Pages
    1 2 3 4 5
    • Replies: 265
    • Views: 18,382
    09-11-2013, 07:10 PM Go to last post
    • Replies: 1
    • Views: 5,461
    09-03-2013, 08:03 PM Go to last post
  36. Separate building

    Started by Tripp Bailey, 08-31-2013 05:28 PM
    • Replies: 9
    • Views: 6,070
    09-02-2013, 01:39 PM Go to last post
  37. Thumbs up Failures in Outlet Testing Exposed

    Started by Brian Hannigan, 08-12-2013 08:24 PM
    • Replies: 14
    • Views: 3,064
    09-01-2013, 05:54 PM Go to last post
  38. Damaged panel

    Started by Marc M, 08-29-2013 06:30 AM
    • Replies: 4
    • Views: 5,685
    08-30-2013, 04:57 AM Go to last post
  39. What is this tap under the breaker?

    Started by Ken Amelin, 08-27-2013 09:12 AM
    • Replies: 8
    • Views: 2,391
    08-29-2013, 06:06 AM Go to last post
  40. Read much?

    Started by John Arnold, 08-22-2013 06:24 AM
    • Replies: 0
    • Views: 1,419
    08-22-2013, 06:24 AM Go to last post
  41. Service Entrance Conductors

    Started by brianmiller, 08-20-2013 08:59 AM
    • Replies: 3
    • Views: 1,705
    08-21-2013, 05:17 PM Go to last post
  42. Megger testing of residential circuits

    Started by Don Hester, 08-17-2013 04:36 PM
    • Replies: 14
    • Views: 10,349
    08-21-2013, 12:35 PM Go to last post
  43. Electrical cable routing

    Started by brianmiller, 08-17-2013 04:44 AM
    • Replies: 1
    • Views: 2,191
    08-20-2013, 12:07 PM Go to last post
  44. Conduit out of foundation

    Started by DavidSmith, 08-17-2013 05:11 AM
    • Replies: 6
    • Views: 1,953
    08-20-2013, 06:47 AM Go to last post
  45. Ceiling Fan Wobble

    Started by Mike Kleisch, 08-05-2013 07:38 AM
    • Replies: 5
    • Views: 2,392
    08-19-2013, 01:44 PM Go to last post
  46. Location of Main Panel

    Started by Mike Tracy, 08-13-2013 03:45 AM
    • Replies: 7
    • Views: 2,385
    08-19-2013, 01:18 PM Go to last post
  47. Question Arc Fault code interpetation

    Started by Mike Schulz, 08-17-2013 05:49 AM
    afci, electrical
    • Replies: 6
    • Views: 3,542
    08-19-2013, 05:33 AM Go to last post
  48. Light switches in bedroom trip AFCI breaker

    Started by Nick McBurney, 03-25-2010 04:46 PM
    • Replies: 48
    • Views: 41,899
    08-18-2013, 07:33 AM Go to last post
  49. pool electrical panel / gas regulator

    Started by brianmiller, 08-17-2013 01:19 PM
    • Replies: 2
    • Views: 1,442
    08-18-2013, 07:03 AM Go to last post
  50. Plugged In Double Wide Manufactured Home

    Started by Chris Skoczylas, 08-08-2013 03:19 PM
    • Replies: 11
    • Views: 5,346
    08-18-2013, 06:59 AM Go to last post
  51. Sub-panels

    Started by Richard Roshak, 08-17-2013 05:40 PM
    • Replies: 2
    • Views: 1,485
    08-17-2013, 07:18 PM Go to last post
    • Replies: 5
    • Views: 2,004
    08-17-2013, 05:15 AM Go to last post
  52. Phone in Tub Area

    Started by Jim Robinson, 08-03-2013 03:01 PM
    • Replies: 12
    • Views: 2,431
    08-16-2013, 05:18 PM Go to last post
  53. NM Liquid Tight Question

    Started by brianmiller, 08-16-2013 12:59 PM
    • Replies: 0
    • Views: 1,336
    08-16-2013, 12:59 PM Go to last post
    • Replies: 3
    • Views: 2,235
    08-15-2013, 07:13 PM Go to last post
  54. Enclosed panel manufacturer???

    Started by Edward Sloan, 08-03-2013 07:58 AM
    • Replies: 24
    • Views: 5,127
    08-13-2013, 10:59 AM Go to last post
    • Replies: 9
    • Views: 3,341
    08-12-2013, 08:30 AM Go to last post
  55. GFCI required in outbuilding?

    Started by Steve C., 08-03-2013 08:02 AM
    • Replies: 15
    • Views: 5,075
    08-12-2013, 08:03 AM Go to last post
    • Replies: 29
    • Views: 5,257
    08-08-2013, 03:35 PM Go to last post
  56. Hydromassage Tub GFCI

    Started by brianmiller, 08-01-2013 05:36 PM
    • Replies: 9
    • Views: 2,741
    08-06-2013, 04:11 PM Go to last post
  57. Advice needed

    Started by Charles McCracken, 08-04-2013 02:32 PM
    • Replies: 33
    • Views: 3,620
    08-06-2013, 03:50 PM Go to last post
  58. 3 pronged outlets that are ungrounded

    Started by Steve C., 08-06-2013 12:34 PM
    • Replies: 5
    • Views: 3,358
    08-06-2013, 01:25 PM Go to last post
  59. House with no electricity

    Started by mark petty, 07-17-2013 04:42 AM
    • Replies: 6
    • Views: 2,300
    08-04-2013, 05:48 AM Go to last post
  60. Double Tap Off Main Lugs

    Started by Nick Ostrowski, 07-18-2013 11:57 AM
    • Replies: 36
    • Views: 16,417
    07-24-2013, 10:00 AM Go to last post
  61. Commercial Zinsco switchboards

    Started by Michael Choffin, 07-22-2013 01:48 PM
    • Replies: 1
    • Views: 2,148
    07-23-2013, 07:05 AM Go to last post

Thread Display Options

Use this control to limit the display of threads to those newer than the specified time frame.

Allows you to choose the data by which the thread list will be sorted.

Order threads in...

Note: when sorting by date, 'descending order' will show the newest results first.

Icon Legend

Contains unread posts
Contains unread posts
Contains no unread posts
Contains no unread posts
More than 25 replies or 10000 views
Hot thread with unread posts
More than 25 replies or 10000 views
Hot thread with no unread posts
Closed Thread
Thread is closed
Thread Contains a Message Written By You
You have posted in this thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •