InspectionNews - Home Inspection



Welcome to the InspectionNews - Home Inspection forums.

You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 05-16-2007, 04:17 PM
John Stephenson John Stephenson is offline
Member
 
Join Date: May 2007
Location: Columbus, Ohio
Posts: 73
Electrical cable insulation cover
..........

Last edited by John Stephenson : 12-22-2007 at 08:38 AM.
Reply With Quote
  #2 (permalink)  
Old 05-16-2007, 04:26 PM
Jim Robinson's Avatar
Jim Robinson Jim Robinson is offline
Member
 
Join Date: Mar 2007
Location: New Mexico
Posts: 293
Re: Electrical cable insulation cover
I was always told to remove it because it was a flammable material from inside the panel.
__________________
Jim Robinson
New Mexico, USA
Reply With Quote
  #3 (permalink)  
Old 05-16-2007, 04:59 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,523
Re: Electrical cable insulation cover
With everything else which is wrong in that panel ... I would only mention it in passing, as in ...

Get a QUALIFIED and LICENSED electrical contractor out to correct all the sh*t in this panel, including, but not limited to: (make list, including that item - but that is the least of their problems).

Only I always said it nicer in my reports.
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #4 (permalink)  
Old 05-16-2007, 06:06 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,523
Re: Electrical cable insulation cover
Quote:
Originally Posted by John Stephenson View Post
I'd just like to know if the sheathing in panel causing overheating to the conductor.
For practical intents and purposes, no.

With sophisticated equipment, I'm sure one could measure a slight increase after a while with a load on it, however, it would not be a problem.

I'm not recalling anything which prohibits sloppy work like that, other than ones own pride in their work (which, obviously, was non-existent there).

That is, other than the vague:
- NEC
- - 110.12 Mechanical Execution of Work.
- - - Electrical equipment shall be installed in a neat and workmanlike manner.
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #5 (permalink)  
Old 05-16-2007, 08:25 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,523
Re: Electrical cable insulation cover
Quote:
Originally Posted by Jeff Eastman View Post
I've wondered why the sheathing wasn't allowed more than 1 1/2 " (?) into panel.
I keep seeing HIs saying 1-1/2" or thereabouts, any idea where you got it from?

"Workmanship" would put it such that the outer sheather was trimmed off 'just inside the strain relief clamp'.

Quote:
I don't see where it would cause overheating or any other issue.
I don't see were running an NM cable, sheath and all, up almost to the breaker, then slit the sheath far enough to allow the grounding conductor to reach the grounding terminals, the neutral conductor to reach the neutral terminals, and the hot conductor to reach the breaker. Sure, it would "look" *ugly as sin*, but I don't know what problems it would cause, other than contributing to physical excess fill - but if the sheath puts you into an 'overfill' condition, I suspect it was already overfilled with conductors.

Anyone have an authoritative source on that 1-1/2"? I mean a *real* authoritative source.
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Electrical cable water heater dan orourke Plumbing System: Home Inspection and Commercial Inspection 3 04-30-2007 11:02 PM
Freestanding patio cover Eric Laney Exterior Systems: Home Inspection and Commercial Inspection 5 04-30-2007 09:48 PM
Insulation type Jeff Eastman Attic Areas: Home Inspection and Commercial Inspection 6 04-07-2007 08:47 AM
Table of Contents on the Cover Page? Mike Paris H E L P ! 2 04-01-2007 11:47 PM


All times are GMT -7. The time now is 06:14 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger