InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 11-02-2009, 09:13 PM
Richard Flores Richard Flores is offline
Member
 
Join Date: Sep 2009
Location: South
Posts: 11
Who is to blame on this one
This was a first for me.. The cable was not buried more than 2-3" throughout the property. What do you guys think about this?
Attached Images
File Type: jpg DSCF2366.JPG (99.5 KB, 166 views)
__________________
Richard Flores
Professional Inspector TREC # 8139
www.premier-rgv.com
Reply With Quote
FREA Home Inspector Insurance
  #2 (permalink)  
Old 11-02-2009, 09:23 PM
Speedy Petey Speedy Petey is offline
Member
 
Join Date: Apr 2009
Location: NY State
Posts: 186
Re: Who is to blame on this one
That has GOT to be a temp service that slipped through the cracks. Hell, the meter pan cover is even hanging off.

That's also a 200A MP and the cable does not look like 200A to me. Hell, look at that house in the background. Seems like a higher end neighborhood.
Reply With Quote
  #3 (permalink)  
Old 11-02-2009, 10:21 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 3,655
Re: Who is to blame on this one
Lets hope someone is not robbing power from the neighbor next door.
Reply With Quote
  #4 (permalink)  
Old 11-02-2009, 10:23 PM
Gunnar Alquist's Avatar
Gunnar Alquist Gunnar Alquist is offline
Member
 
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 1,201
Re: Who is to blame on this one
Who is to blame? Since you found it, you are.
__________________
We have enough youth, how about a fountain of Smart?
Reply With Quote
  #5 (permalink)  
Old 11-02-2009, 10:32 PM
Vern Heiler's Avatar
Vern Heiler Vern Heiler is online now
Member
 
Join Date: Mar 2008
Location: Charlotte NC
Posts: 629
Re: Who is to blame on this one
Quote:
Originally Posted by Speedy Petey View Post
That has GOT to be a temp service that slipped through the cracks. Hell, the meter pan cover is even hanging off.

That's also a 200A MP and the cable does not look like 200A to me. Hell, look at that house in the background. Seems like a higher end neighborhood.
His location says he's in the South. I think Rick has it pegged! Sombody getten some free electricity .
Reply With Quote
  #6 (permalink)  
Old 11-03-2009, 12:15 AM
Brandon Whitmore Brandon Whitmore is offline
Member
 
Join Date: Jun 2007
Location: Oregon
Posts: 625
Re: Who is to blame on this one
This is some kind of joke........... isn't it
Reply With Quote
  #7 (permalink)  
Old 11-03-2009, 06:16 AM
Vern Heiler's Avatar
Vern Heiler Vern Heiler is online now
Member
 
Join Date: Mar 2008
Location: Charlotte NC
Posts: 629
Re: Who is to blame on this one
Quote:
Originally Posted by Brandon Whitmore View Post
This is some kind of joke........... isn't it
I've seen stolen gas meters and water meters, presumably used to hook up a disconnected service. This looks like the electrical is being stolen from the pictured meter. The house next door might have been going down the foreclosure tube and they needed a little more time with electricity.
Reply With Quote
  #8 (permalink)  
Old 11-03-2009, 03:09 PM
Speedy Petey Speedy Petey is offline
Member
 
Join Date: Apr 2009
Location: NY State
Posts: 186
Re: Who is to blame on this one
Quote:
Originally Posted by Vern Heiler View Post
His location says he's in the South. I think Rick has it pegged! Sombody getten some free electricity .
You guys may be on to something.
Reply With Quote
  #9 (permalink)  
Old 11-03-2009, 06:24 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: Who is to blame on this one
I don't see where there is any riser going to that meter for its real service lateral, which leads me to suspect that it was connected "temporarily" at the time of construction to power up the house while waiting for the power company to come out and run the service lateral ... which never happened, leaving it that way since it was built ... and quite likely being run *from* (rather than run *to*) the house on the right.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #10 (permalink)  
Old 11-03-2009, 08:19 PM
Vern Heiler's Avatar
Vern Heiler Vern Heiler is online now
Member
 
Join Date: Mar 2008
Location: Charlotte NC
Posts: 629
Re: Who is to blame on this one
Quote:
Originally Posted by Jerry Peck View Post
I don't see where there is any riser going to that meter for its real service lateral, which leads me to suspect that it was connected "temporarily" at the time of construction to power up the house while waiting for the power company to come out and run the service lateral ... which never happened, leaving it that way since it was built ... and quite likely being run *from* (rather than run *to*) the house on the right.
I know its not in a conduit, but what is the cable coming up the wall into the meter?

I don't know about other areas but the power company will only run temp power to a temp service pole here.
Reply With Quote
  #11 (permalink)  
Old 11-03-2009, 08:38 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: Who is to blame on this one
Quote:
Originally Posted by Vern Heiler View Post
I know its not in a conduit, but what is the cable coming up the wall into the meter?
I'm thinking that is the grounding electrode conductor protected in PVC.

Quote:
I don't know about other areas but the power company will only run temp power to a temp service pole here.
Every where I've been is that same way, but who knows 'in the "South" wherever that may be'.

Saying one is in the "South" is about like saying one is in the "US", that covers a LOT of area.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #12 (permalink)  
Old 11-04-2009, 01:58 PM
H.G. Watson, Sr.'s Avatar
H.G. Watson, Sr. H.G. Watson, Sr. is offline
Member
 
Join Date: Jul 2008
Location: Snowbird, FL/MI
Posts: 510
Re: Who is to blame on this one
Quote:
Originally Posted by Jerry Peck View Post
Saying one is in the "South" is about like saying one is in the "US", that covers a LOT of area.
His signature line includes a Texas License number and a web-site link.

I think its safe to presume he and the subject property are represented to be in Texas.
Reply With Quote
  #13 (permalink)  
Old 11-04-2009, 06:29 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: Who is to blame on this one
Quote:
Originally Posted by H.G. Watson, Sr. View Post
His signature line includes a Texas License number and a web-site link.

I think its safe to presume he and the subject property are represented to be in Texas.
While that is true on that presumption, I only looked at his location at 'Location', not down in his signature.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #14 (permalink)  
Old 11-04-2009, 07:24 PM
Ted Menelly Ted Menelly is offline
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 3,074
Re: Who is to blame on this one
McAllen, Texas 78503
__________________
Ted Menelly
Castle Home Inspection Services
www.inspectmycastle.com
Reply With Quote
  #15 (permalink)  
Old 11-11-2009, 10:30 PM
Richard Flores Richard Flores is offline
Member
 
Join Date: Sep 2009
Location: South
Posts: 11
Re: Who is to blame on this one
I am in the southern most part of the State. A few minutes from Mexico.. AEP (energy provider) requires us to dig a trench no less than 40" from transformer to edge of home where Meter is to be located. So the PVC pipe that you see is the one that is suppose to be buried underground. It goes all along the properly buried no more than 2" at its deepest and does terminate at the appropriate transformer. What gets me is how the previous owner never complained about this. The house is a foreclosure but it does show signs of children living in it. Meaning that either the homeowner worked for the service provider or a friend of his worked for one. I called AEP and had them go take a look.. BTW you can rest assure that the buyer walked away from this one.
__________________
Richard Flores
Professional Inspector TREC # 8139
www.premier-rgv.com
Reply With Quote
  #16 (permalink)  
Old 11-11-2009, 10:38 PM
H.G. Watson, Sr.'s Avatar
H.G. Watson, Sr. H.G. Watson, Sr. is offline
Member
 
Join Date: Jul 2008
Location: Snowbird, FL/MI
Posts: 510
Re: Who is to blame on this one
RF:

Thanks for the update.
Reply With Quote
Are inspection referrals from past clients important to you? If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Who's to blame for a rotten house? - The Olympian Brian Hannigan Associations, Ethics, Standards, Licensing, Legislation:Home Inspectors & Commercial Inspectors 0 05-29-2007 05:31 AM
Who's to blame when a home sale goes sour after the buyer moves in? - Salt Lake Tribu Brian Hannigan Inspection News From Around The Net 0 05-13-2007 02:31 AM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 09:04 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger