You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

07-16-2007, 10:15 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Broadview Heights, Ohio
Posts: 17
|
|
|
Height requirement for exterior box
This GFCI controlled outlet was at ground level.
What if any requirements are for the height of the box?
|
|

07-16-2007, 10:25 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,185
|
|
|
Re: Height requirement for exterior box
David - I don't know the answer to your question, but it immediately occurred to me to see where you are from, thinking about snow, for one thing, but you haven't filled out your profile.
|
|

07-16-2007, 10:31 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Broadview Heights, Ohio
Posts: 17
|
|
|
Re: Height requirement for exterior box
Originally Posted by John Arnold
David - I don't know the answer to your question, but it immediately occurred to me to see where you are from, thinking about snow, for one thing, but you haven't filled out your profile.
I am from snow country in Northeast Ohio.
I will have to update my profile.
Thanks
|
|

07-16-2007, 10:42 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,185
|
|
|
Re: Height requirement for exterior box
2006 IRC E3801.7 Outdoor outlets. At least one receptacle outlet accessible at grade level and not more than 6 feet, 6 inches above grade, shall be installed outdoors at the front and back of each dwelling unit having direct access to grade.
|
|

07-16-2007, 10:54 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Broadview Heights, Ohio
Posts: 17
|
|
|
Re: Height requirement for exterior box
Originally Posted by John Arnold
2006 IRC E3801.7 Outdoor outlets. At least one receptacle outlet accessible at grade level and not more than 6 feet, 6 inches above grade, shall be installed outdoors at the front and back of each dwelling unit having direct access to grade.
So from the IRC it is acceptable to install at grade level. So what if it snows 6-12 inches?
|
|

07-16-2007, 10:57 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,185
|
|
|
Re: Height requirement for exterior box
Originally Posted by David Macy
So from the IRC it is acceptable to install at grade level. So what if it snows 6-12 inches?
I don't know. Seems like a concern to me. I did notice in my CodeCheck Electrical it says "In most cases. the NEC does not have requirements for switch or receptacle height", then goes on to talk about the Americans with Disabilities Act.
|
|

07-16-2007, 11:45 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Cartersville, GA
Posts: 69
|
|
|
Re: Height requirement for exterior box
Not sure what code says about it, but that receptacle looks like lawn mower candy to me....
|
|

07-16-2007, 11:51 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Broadview Heights, Ohio
Posts: 17
|
|
|
Re: Height requirement for exterior box
Originally Posted by Bob White
Not sure what code says about it, but that receptacle looks like lawn mower candy to me....
Actually I would do a nice number on the box with my weadeater!
By the way How do you like my profile. This is the time of year I usually go to Canada and unfortunetly will not be going this year.
I hear the loons, labatts and fish calling me!!
|
|

07-16-2007, 03:56 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,547
|
|
|
Re: Height requirement for exterior box
If it is buried at all, it must be a direct burial rated box ... which means gasketed cover and no openings (like receptacles) which could allow water in.
If it is 'just above grade' but in a depression area and you see a high water mark around it, I wrote them up as needing to be direct burial/underwater rated.
If it is 'just above grade' and no evidence of water ... there is no 'minimum height' requirement.
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| electric eye height |
wayne soper |
Exterior Systems: Home Inspection and Commercial Inspection |
10 |
06-10-2008 09:39 AM |
| Interior stairway riser height |
dan orourke |
Building Interior: Home Inspection and Commercial Inspection |
6 |
06-19-2007 06:47 AM |
| Exterior steps |
dan orourke |
Building Envelope: Home Inspection and Commercial Inspection |
4 |
05-30-2007 04:30 PM |
| Plumbing vent height |
John Stephenson |
Plumbing System: Home Inspection and Commercial Inspection |
17 |
05-23-2007 12:44 PM |
| Exterior JB |
Warren Alderman |
Electrical Systems: Home Inspection and Commercial Inspection |
3 |
04-12-2007 05:56 PM |
All times are GMT -7. The time now is 07:29 AM.
| | |
|