You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 04-19-2007, 11:22 AM
Kevin Luce's Avatar
Kevin Luce Kevin Luce is offline
Member
 
Join Date: Mar 2007
Location: Highland, IN
Posts: 369
Electrical service box located in closet
I came across a slab house that was built in 1993. The service panel was installed in a walk in closet. I was wondering what year that installing service panels in the closets was not allowed.

Thanks for the help ahead of time.
__________________
I say lets merge all the home inspection organizations into one.

Seepaluce
Reply With Quote
  #2 (permalink)  
Old 04-19-2007, 12:51 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
Re: Electrical service box located in closet
A long ... long ... long ... long .. and-even-longer ... time ago.

As long as (here's that *if*) by "closet" you are referring to a "clothes closet" or another type of closet with "readily ignitable" material in it.

*Most* closets would: a) not be large enough, and, b) be used for storage of materials and items which would make the panel not suitable or allowable to be installed in the closet.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #3 (permalink)  
Old 04-19-2007, 02:17 PM
Kevin Luce's Avatar
Kevin Luce Kevin Luce is offline
Member
 
Join Date: Mar 2007
Location: Highland, IN
Posts: 369
Re: Electrical service box located in closet
Quote:
Originally Posted by Jerry Peck View Post
A long ... long ... long ... long .. and-even-longer ... time ago.
So, are you talking about your preteen years or teenage years?

During the inspection, the buyer informed me that her husband is an electrician. They just remodeled the basement at the house they are going to sell and the electrical panel is located in the clothes closet. When she got home and talked to her husband, her husband confirmed that the panel (in the new house) should not have been installed in the clothes closet. When she reminded him where the panel is located in their basement, his only words were "Oh ****!". She called me up to tell me that story.
__________________
I say lets merge all the home inspection organizations into one.

Seepaluce

Last edited by Kevin Luce : 04-19-2007 at 02:21 PM. Reason: **** = excrement
Reply With Quote
  #4 (permalink)  
Old 04-19-2007, 02:30 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,396
Re: Electrical service box located in closet
If you take out the clothing rod and you don't store clothes in it, it no longer a clothes closet correct(?)
__________________
Rick Hurst_Home Works Inspection Co_Rockwall TX
In the words of Mike Tyson.... "Everyone has a plan until they get hit inda mouf"
Reply With Quote
  #5 (permalink)  
Old 04-19-2007, 04:17 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
Re: Electrical service box located in closet
Quote:
Originally Posted by Rick Hurst View Post
If you take out the clothing rod and you don't store clothes in it, it no longer a clothes closet correct(?)
It is no longer a "clothes closet", but that is (as I was pointing out) only *part of* the story.

For the rest of the story, here is the NEC code on it.
- ARTICLE 240 Overcurrent Protection
- - 240.24 Location in or on Premises.
- - - (D) Not in Vicinity of Easily Ignitible Material. Overcurrent devices shall not be located in the vicinity of easily ignitible material, such as in clothes closets.

Catch the "such as"? It is not 'shall not be located *IN* clothes closets', it is 'shall not be located *IN THE VICINITY OF* "easily ignitible material" ... 'such as' ... in clothes closets.

Take out the clothes rod and you will still have stored items which would be "easily ignitible", which would STILL PROHIBIT the panel from being installed there.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #6 (permalink)  
Old 04-19-2007, 08:44 PM
Kevin Luce's Avatar
Kevin Luce Kevin Luce is offline
Member
 
Join Date: Mar 2007
Location: Highland, IN
Posts: 369
Re: Electrical service box located in closet
Quote:
Originally Posted by Jerry Peck View Post
It is no longer a "clothes closet", but that is (as I was pointing out) only *part of* the story.

For the rest of the story, here is the NEC code on it.
- ARTICLE 240 Overcurrent Protection
- - 240.24 Location in or on Premises.
- - - (D) Not in Vicinity of Easily Ignitible Material. Overcurrent devices shall not be located in the vicinity of easily ignitible material, such as in clothes closets.

Catch the "such as"? It is not 'shall not be located *IN* clothes closets', it is 'shall not be located *IN THE VICINITY OF* "easily ignitible material" ... 'such as' ... in clothes closets.

Take out the clothes rod and you will still have stored items which would be "easily ignitible", which would STILL PROHIBIT the panel from being installed there.
You would think that for the people that pay for these classes and/or home study courses, that this type of information would be included.

"Watch for panels in bathrooms, clothes closets, stairwells, and kitchen cabinets. Watch also for panels too close to gas meters or gas relief vents" are some of the general information that is being taught.
__________________
I say lets merge all the home inspection organizations into one.

Seepaluce
Reply With Quote
  #7 (permalink)  
Old 04-19-2007, 08:49 PM
Kevin Luce's Avatar
Kevin Luce Kevin Luce is offline
Member
 
Join Date: Mar 2007
Location: Highland, IN
Posts: 369
Re: Electrical service box located in closet
Quote:
Originally Posted by Rick Hurst View Post
If you take out the clothing rod and you don't store clothes in it, it no longer a clothes closet correct(?)
Depending on how large the space is but some people around here would then call it an office.
__________________
I say lets merge all the home inspection organizations into one.

Seepaluce
Reply With Quote
  #8 (permalink)  
Old 04-19-2007, 11:09 PM
Tim Moreira's Avatar
Tim Moreira Tim Moreira is offline
Member
 
Join Date: Mar 2007
Location: New Port Richey, Fl
Posts: 446
Re: Electrical service box located in closet
Kevin,

Quote:
You would think that for the people that pay for these classes and/or home study courses, that this type of information would be included.
This board is the best home study course you'll ever find.

I wish I had found this before I paid 3 grand to ITA.
Reply With Quote
  #9 (permalink)  
Old 03-25-2008, 08:01 PM
j.Peter Buss j.Peter Buss is offline
Member
 
Join Date: Dec 2007
Location: Chicago
Posts: 5
Re: Check out these undersized wires !
Hi, Check this out,

This is from an inspection i performed today in chicago, people were living in the house with this condition for some time - Main drop entrance cable (Hot & Neutral) in service panel spliced with a # 14 wires to the 100 amp main breaker and neutral bar - Wow !! The drop cable was not long enough at installation so this is how he/she repaired the issue.


Peter Buss
Buss Inspection Services, Inc
Buss Inspection Services, Inc.
Attached Images
File Type: jpg 3445 N Ozanam Ave Chicago 059.jpg (80.4 KB, 98 views)
File Type: jpg 3445 N Ozanam Ave Chicago 059a.JPG (74.8 KB, 105 views)
__________________
Peter Buss
Reply With Quote
  #10 (permalink)  
Old 03-25-2008, 08:50 PM
mathew stouffer mathew stouffer is offline
Member
 
Join Date: Mar 2008
Location: Park City, Utah
Posts: 188
Re: Electrical service box located in closet
Tim,
Wish you would have talked to me before attending ITA. I did the same thing, that place is a joke.
Reply With Quote
  #11 (permalink)  
Old 03-26-2008, 06:38 AM
Bob White's Avatar
Bob White Bob White is offline
Member
 
Join Date: Mar 2007
Location: Cartersville, GA
Posts: 74
Re: Check out these undersized wires !
Quote:
Originally Posted by j.Peter Buss View Post
Hi, Check this out,

This is from an inspection i performed today in chicago, people were living in the house with this condition for some time - Main drop entrance cable (Hot & Neutral) in service panel spliced with a # 14 wires to the 100 amp main breaker and neutral bar - Wow !! The drop cable was not long enough at installation so this is how he/she repaired the issue.


Peter Buss
Buss Inspection Services, Inc
Buss Inspection Services, Inc.

Fusible link.
__________________
Bob White

www.abide-able.com
Reply With Quote
  #12 (permalink)  
Old 03-26-2008, 07:22 AM
David Banks David Banks is offline
Member
 
Join Date: Mar 2007
Location: Southborough, MA
Posts: 964
Re: Check out these undersized wires !
Quote:
Originally Posted by Bob White View Post
Fusible link.
Bob. Did you have a Tornado?
__________________
Dave
Reply With Quote
  #13 (permalink)  
Old 03-26-2008, 07:42 AM
Kevin Luce's Avatar
Kevin Luce Kevin Luce is offline
Member
 
Join Date: Mar 2007
Location: Highland, IN
Posts: 369
Re: Electrical service box located in closet
Quote:
Originally Posted by mathew stouffer View Post
Tim,
Wish you would have talked to me before attending ITA. I did the same thing, that place is a joke.
I agree! The hint is in their advertising "fast-paced instruction". I could of almost got the same thing from a video tape (Oops DVD).

Can you see us advertising this as home inspectors. "Fast-paced home inspection"
__________________
I say lets merge all the home inspection organizations into one.

Seepaluce

Last edited by Kevin Luce : 03-26-2008 at 07:45 AM. Reason: Added Oops DVD and the last line.
Reply With Quote
  #14 (permalink)  
Old 03-26-2008, 07:50 AM
James Duffin James Duffin is offline
Member
 
Join Date: May 2007
Location: NC
Posts: 478
Re: Electrical service box located in closet
Quote:
Originally Posted by Jerry Peck View Post
It is no longer a "clothes closet", but that is (as I was pointing out) only *part of* the story.

For the rest of the story, here is the NEC code on it.
- ARTICLE 240 Overcurrent Protection
- - 240.24 Location in or on Premises.
- - - (D) Not in Vicinity of Easily Ignitible Material. Overcurrent devices shall not be located in the vicinity of easily ignitible material, such as in clothes closets.

Catch the "such as"? It is not 'shall not be located *IN* clothes closets', it is 'shall not be located *IN THE VICINITY OF* "easily ignitible material" ... 'such as' ... in clothes closets.

Take out the clothes rod and you will still have stored items which would be "easily ignitible", which would STILL PROHIBIT the panel from being installed there.

If the closet is empty except for the panel and you have the proper clearances why wouldn't it be legal then?
Reply With Quote
  #15 (permalink)  
Old 03-26-2008, 08:11 AM
Kevin Luce's Avatar
Kevin Luce Kevin Luce is offline
Member
 
Join Date: Mar 2007
Location: Highland, IN
Posts: 369
Re: Electrical service box located in closet
You have a bedroom with a closet (normally the only closet). What is the odds that the space is going to be used as storage (boxes, clothing items) by the new homeowners (high). Plus if the sellers are using it as storage, the buyers are going to assume that they can also use it as storage until we tell them different during the home inspection. Now that little part of the house should not be used as built unless the panel or closet is relocated.

Around here, they don't care too much about the panels located in closets. I inspected a house built in the 50's that just upgraded the panel to a 100 amp service and they left in the closet. The city inspector informed the buyers, sellers and Realtors that it's fine. I had another house in a different town that was 2 years old and the panel was placed in a small walk in closet. The buyers husband was an electrician and knew about the code but the town said it was fine.

I still cover myself when writing up the report.
__________________
I say lets merge all the home inspection organizations into one.

Seepaluce

Last edited by Kevin Luce : 03-26-2008 at 11:37 AM. Reason: corrected a few spelling errors
Reply With Quote
  #16 (permalink)  
Old 03-26-2008, 10:58 AM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
Re: Electrical service box located in closet
Quote:
Originally Posted by Kevin Luce View Post
Around here, they don't care too much about the panels located in closets. I inspected a house built in the 50's that just upgraded the panel to a 100 amp service and they left in the closet. The city inspector informed the buyers, sellers and Realtors that it's fine. I had another house in a different town that was 2 years old and the panel was placed in a small walk in closet. The buyers husband was an electrician and new about the code but the town said it was fine.

Kevin,

Those are the types of places (towns) where it would be in your interest to not only 'get to know' the Building Official but the Fire Chief as well, then, ask the Fire Chief 'I'm a little concerned about something I keep finding, I find electrical panels in clothes closets, and, here in the NEC (bring your code book and show him) it says that they should not be in clothes closets or in the vicinity of easily ignitable material. I write them up but real estate agents keep saying 'it's no big deal' ... I'm wondering what your thoughts on it are?'

After he answers (presuming he will answer to the effect that those panels should not be there), you ask a few more questions to 'clarify' (baiting the hook more), then finally say 'Would you talk to XXX, the Building Official / Chief Electrical Inspector because they keep allowing it and saying it is fine, and, like you, I am concerned with the fire aspect.'

Bingo! You've got him nailed, on your side, and he will likely talk to the Building Official / Chief Electrical Inspector - if for no other reason than the say 'Hey man, I know we need to stay busy, but you don't have to go around starting fires for us.', to which the Building Official / Chief Electrical Inspectors says 'What? What are you talking about?' Therein starts a discussion for which I would love to be a fly on the wall listening to what is said, why, and the explanations given.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #17 (permalink)  
Old 05-27-2008, 07:44 PM
Ted Menelly Ted Menelly is offline
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 1,235
Re: Electrical service box located in closet
The only problem with all this discussion and code stuff is,,,,,,,,,, When have you inspected almost anyhome whether it be in a closet, garage etc. where people don't store goods all around it. At least out of the closet it is easier to move things from in front of it.

HVAC and or gas water heater closet or combo. Same thing, they use it for storage and pack everything in around it.

All our good work inspecting gone to hell.
Reply With Quote
  #18 (permalink)  
Old 05-28-2008, 08:40 PM
Randy Clayton Randy Clayton is offline
Member
 
Join Date: Apr 2008
Location: Katy Texas
Posts: 105
Re: Electrical service box located in closet
you can only report on whats there;you can not report on ones habits or doings!!!!