You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 03-15-2008, 12:12 PM
Victor DaGraca's Avatar
Victor DaGraca Victor DaGraca is offline
Member
 
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 281
De-rating Revisited
Would you say that this bundle should be de-rated and/or appropriate repairs be conducted by a licensed and qualified electrician?
I already called out the missing knockout.


And, while I'm at it.... there was an addition to this house... a patio was enclosed.... some electrical was run.... all other breakers being original.... all squareD.... this one caught my eye.... could it be one of those bogus SquareD breakers?
Attached Images
File Type: jpg 3765.jpg (62.6 KB, 141 views)
File Type: jpg 3769.jpg (32.6 KB, 116 views)
__________________
Critical Home Inspection Services
www.Home2Spec.com

Last edited by Victor DaGraca : 03-15-2008 at 12:19 PM. Reason: after thought
Reply With Quote
Are inspection referrals from past clients important to you?
If so, click here to get even more referrals!
  #2 (permalink)  
Old 03-15-2008, 12:19 PM
John Arnold John Arnold is online now
Member
 
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,185
Re: De-rating Revisited
Quote:
Originally Posted by Victor DaGraca View Post
Would you say that this bundle should be de-rated and/or appropriate repairs be conducted by a licensed and qualified electrician?
I already called out the missing knockout.
Everything shouldn't be stuffed through together like that, but for de-rating they have to be bundled for at least 24 inches, if memory serves.
Reply With Quote
  #3 (permalink)  
Old 03-15-2008, 12:27 PM
Victor DaGraca's Avatar
Victor DaGraca Victor DaGraca is offline
Member
 
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 281
Re: De-rating Revisited
Thanks John.... now that you mentioned the 24"......
__________________
Critical Home Inspection Services
www.Home2Spec.com
Reply With Quote
  #4 (permalink)  
Old 03-15-2008, 12:56 PM
Gunnar Alquist's Avatar
Gunnar Alquist Gunnar Alquist is offline
Member
 
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 596
Re: De-rating Revisited
I think that you will also find that strain relief clamps are required, not a bushing.
__________________
What is the circumference of a moose?
Reply With Quote
  #5 (permalink)  
Old 03-15-2008, 01:40 PM
David Banks David Banks is offline
Member
 
Join Date: Mar 2007
Location: Southborough, MA
Posts: 912
Re: De-rating Revisited
Connecticut Electric Recalls Counterfeit Square D Circuit Breakers Due To Fire Hazard
__________________
Dave
Reply With Quote
  #6 (permalink)  
Old 03-16-2008, 06:18 AM
Victor DaGraca's Avatar
Victor DaGraca Victor DaGraca is offline
Member
 
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 281
Re: De-rating Revisited
David;
Here's the problem I'm having....

your link shows a genuine breaker .... Connecticut Electric Recalls Counterfeit Square D Circuit Breakers Due To Fire Hazard

this link shows a counterfeit.....
Counterfeit "Square D" Circuit Breakers

They look Identical

The best comparison I got was at North American Breaker Co. Recalls Counterfeit Circuit Breakers Due to Fire Hazard

Now.... look again at the picture I posted.... They look nothing like the genuine OR the counterfeit....

I e-mailed Schneider electric hoping to get an answer...


here's a pic of the comparison
Attached Images
File Type: jpg SDcompare.jpg (47.8 KB, 56 views)
File Type: jpg SDcompare2.jpg (48.0 KB, 56 views)
__________________
Critical Home Inspection Services
www.Home2Spec.com
Reply With Quote
  #7 (permalink)  
Old 03-16-2008, 06:54 AM
David Banks David Banks is offline
Member
 
Join Date: Mar 2007
Location: Southborough, MA
Posts: 912
Re: De-rating Revisited
Quote:
Originally Posted by Victor DaGraca View Post
David;
Here's the problem I'm having....

your link shows a genuine breaker .... Connecticut Electric Recalls Counterfeit Square D Circuit Breakers Due To Fire Hazard

this link shows a counterfeit.....
Counterfeit "Square D" Circuit Breakers

They look Identical

The best comparison I got was at North American Breaker Co. Recalls Counterfeit Circuit Breakers Due to Fire Hazard

Now.... look again at the picture I posted.... They look nothing like the genuine OR the counterfeit....

I e-mailed Schneider electric hoping to get an answer...


here's a pic of the comparison
I had the same problem looking at your pics. Thats why I posted the link with no comment. Good luck.
__________________
Dave
Reply With Quote
  #8 (permalink)  
Old 03-16-2008, 09:28 AM
Lee Nettnin's Avatar
Lee Nettnin Lee Nettnin is offline
Member
 
Join Date: Mar 2007
Location: Hamlin, New York
Posts: 76
Re: De-rating Revisited
Victor,
I believe your breaker is one of Square D's new Homeline series and is made to fit other panel boxes as well as there own.
Lee
__________________
www.eagleeyeinspectionshome.com
Reply With Quote
  #9 (permalink)  
Old 03-16-2008, 08:27 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,521
Re: De-rating Revisited
Quote:
Originally Posted by Gunnar Alquist View Post
I think that you will also find that strain relief clamps are required, not a bushing.
Yep.

So, even if they are like that for less than 24" ... they are *STILL* "wrong".
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #10 (permalink)  
Old 03-16-2008, 08:58 PM
Victor DaGraca's Avatar
Victor DaGraca Victor DaGraca is offline
Member
 
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 281
Re: De-rating Revisited
Jerry;
Even though I can't ascertain that those wires do or don't run like that for 24" I'd still "assume" (dangerous word there) that the amount of wires and their proximity within that orifice would produce excessive heat build up.

Of course I'm not an electrician or an engineer and even the IRC does not specifically dis-allow (prohibit) that specific scenario, that being said.... if it looks like a duck......
__________________
Critical Home Inspection Services
www.Home2Spec.com
Reply With Quote
  #11 (permalink)  
Old 03-16-2008, 09:22 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,521
Re: De-rating Revisited
Quote:
Originally Posted by Victor DaGraca View Post
Even though I can't ascertain that those wires do or don't run like that for 24"
That's why I quoted Gunnar (and am doing so again).

Quote:
Originally Posted by Gunnar Alquist View Post
I think that you will also find that strain relief clamps are required, not a bushing.
Forget about the 24" and derating, go on to something which is plainly visible.

Correct THAT, and, by virtue of correcting that, you are also correcting the un-verifiable 24" ... whether or not if it - er - "was" (as in "past tense") 24" or greater, or less, no longer matters.
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #12 (permalink)  
Old 03-17-2008, 04:28 AM
Victor DaGraca's Avatar
Victor DaGraca Victor DaGraca is offline
Member
 
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 281
Re: De-rating Revisited
You know..... sometimes things in plain sight make a dope outa me.... All along I thought Gunnar was refering to the lone wire on the left coming through the bushing. (no strain relief clamp)
THEN.... Outa the blue.......

Thanks Jerry
Thanks Gunnar
Thanks to all...
__________________
Critical Home Inspection Services
www.Home2Spec.com
Reply With Quote
  #13 (permalink)  
Old 03-17-2008, 02:37 PM
Victor DaGraca's Avatar
Victor DaGraca Victor DaGraca is offline
Member
 
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 281
Re: De-rating Revisited
Ok... I received a reply from Schneider Electric. Here it is.
Lee .... Looks like you hit it.

Dear Victor DaGraca:
Thank you for your internet inquiry. I asked the plant and corporate offices to look at this picture. Neither can confirm or deny that the breaker shown on that picture is a counterfeit breaker. From the corporate people, they have said there have been no known instances at this time of counterfeit HOM, or Homeline breakers.

To verify for sure, we would need to have the product returned to us for inspection by one of our engineers. You may contact a local field sales office to initiate this process.

To find the Square D/Schneider Electric Sales Office nearest you, click the following link:
http://ecatalog.squared.com/ssearch/

Please feel free to contact us, should you have any further questions.

Regards,
Kevin McDonald.
Product Support Specialist.
Schneider Electric
1-888-778-2733
__________________
Critical Home Inspection Services
www.Home2Spec.com
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Rating inversion Richard Stanley General Chit Chat: Home Inspectors & Commercial Inspectors 2 09-10-2007 01:47 PM
SEER rating Fritz Kelly Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 3 07-31-2007 07:07 PM
Main breaker rating RobertSmith Electrical Systems: Home Inspection and Commercial Inspection 4 06-01-2007 11:48 AM
Help Please - Revisited Jim Dull Building Envelope: Home Inspection and Commercial Inspection 16 04-20-2007 10:36 PM
SEER rating Buster Foster Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 9 04-08-2007 03:46 PM


All times are GMT -7. The time now is 06:05 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger