You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 4,500 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 05-13-2008, 06:26 PM
Jerome W. Young Jerome W. Young is offline
Member
 
Join Date: Dec 2007
Location: Vero Beach Florida
Posts: 175
multiple taps at main
this looks like it was made for two feeders but not three?
Attached Images
File Type: jpg DSC09428.jpg (44.6 KB, 50 views)
Reply With Quote
Home inspection
  #2 (permalink)  
Old 05-13-2008, 06:38 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,065
Re: multiple taps at main
Made for parallel conductor sets, and, you are correct, one side of each is multiple tapped (and it does not look like it is made for that).

If ... that big *IF* ... if you could have removed those conductors and that lug, you would have been able to see on the lug what it was rated for. It might also state in the wiring diagram or on the label.
__________________
Jerry Peck
Construction / Litigation Consultant www.ConstructionLitigationConsultants.com
Ormond Beach, Florida
Reply With Quote
  #3 (permalink)  
Old 05-13-2008, 08:31 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 1,904
Re: multiple taps at main
How about this one, Jerry?
Attached Images
File Type: jpg CIMG4324.jpg (44.3 KB, 47 views)
Reply With Quote
  #4 (permalink)  
Old 05-14-2008, 01:02 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,065
Re: multiple taps at main
Quote:
Originally Posted by Rick Hurst View Post
How about this one
Rick,

That's commonly referred to as a 'AFU' type connection, typically done by WTFDIK 'electricians'.
__________________
Jerry Peck
Construction / Litigation Consultant www.ConstructionLitigationConsultants.com
Ormond Beach, Florida
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Multiple vapor barriers Jeff Beck Attic Areas: Home Inspection and Commercial Inspection 6 05-06-2008 06:09 AM
Multiple Dampers Michael Thomas Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 10 02-24-2008 10:12 AM
Double Taps Re-visited Victor DaGraca Electrical Systems: Home Inspection and Commercial Inspection 4 08-05-2007 08:15 AM
Double Taps wayne soper Electrical Systems: Home Inspection and Commercial Inspection 7 07-24-2007 12:39 AM
Multiple neutrals under same lug Paul Kondzich Electrical Systems: Home Inspection and Commercial Inspection 28 06-02-2007 07:33 AM


All times are GMT -7. The time now is 11:45 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger