You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 05-14-2008, 06:57 AM
Jonathan Cartwright's Avatar
Jonathan Cartwright Jonathan Cartwright is offline
Member
 
Join Date: Mar 2007
Location: Reno, NV
Posts: 21
Fire suppression light
Inspected a small bakery yesterday. Found this new fangled lighting system. I think it is so you can see the fire suppression system control in the dark.

Have a great day.

Jonathan
Attached Images
File Type: jpg P5130238.jpg (28.3 KB, 48 views)
File Type: jpg P5130237.jpg (35.6 KB, 58 views)
__________________
Jonathan M. Cartwright
Newberry Inspections, LLC
Reply With Quote
Are inspection referrals from past clients important to you?
If so, click here to get even more referrals!
  #2 (permalink)  
Old 05-14-2008, 10:20 AM
mike huntzinger mike huntzinger is offline
Member
 
Join Date: Nov 2007
Location: lincoln,ca
Posts: 36
Re: Fire suppression light
You guys havent seen this before, that is a flashing light for the deaf
Reply With Quote
  #3 (permalink)  
Old 05-14-2008, 11:15 AM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,271
Re: Fire suppression light
Its still wired wrong. Junction are not in the box, no J box lid, and the light fixture should not be supported by the wiring.

rick
Reply With Quote
  #4 (permalink)  
Old 05-14-2008, 12:59 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,041
Re: Fire suppression light
Quote:
Originally Posted by Rick Hurst View Post
Its still wired wrong. Junction are not in the box, no J box lid, and the light fixture should not be supported by the wiring.

rick
Rick,

You must have gotten tired writing down what was wrong, you just scratched the surface. Let's just say that "nothing is correct" about that light installation, from the luminaire itself to the installation of it.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )
Reply With Quote
  #5 (permalink)  
Old 05-14-2008, 04:51 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,271
Re: Fire suppression light
Yeah yeah, just a few quick observations. I was up till 3am. last night yet writing another book.

rick
Reply With Quote
  #6 (permalink)  
Old 05-16-2008, 06:07 PM
John Steinke's Avatar
John Steinke John Steinke is offline
Member
 
Join Date: Mar 2007
Location: Reno, Nv.
Posts: 115
Re: Fire suppression light
Just a fine detail ... not directly relevant to this thread, but worth noting:

NFPA 95 anyone? I've recently had some, ah, enlightening conversations with sundry professionals about these "Ansul" systems ... and NONE had read, much less owned, a copy of the relevant code.
Reply With Quote
Are inspection referrals from past clients important to you?
If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Pendant light over tub fritzkelly Electrical Systems: Home Inspection and Commercial Inspection 21 04-02-2008 03:47 PM
Outside light post ? David Edens Electrical Systems: Home Inspection and Commercial Inspection 3 11-06-2007 02:43 PM
Non IC light cans Jim Robinson Attic Areas: Home Inspection and Commercial Inspection 4 06-12-2007 01:42 PM
Pool Light Wiring Gunnar Alquist Electrical Systems: Home Inspection and Commercial Inspection 5 05-16-2007 09:18 PM
Light switch position. Jeff Eastman Electrical Systems: Home Inspection and Commercial Inspection 4 04-18-2007 06:03 PM


All times are GMT -7. The time now is 01:11 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger