InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-29-2008, 05:39 PM
Ross Neag Ross Neag is offline
Member
 
Join Date: Jul 2007
Location: Chicago
Posts: 72
Condo elec SERVICE
On a condo panel that has NO MAIN, is it service or a subpanel (50 unit bldg)? Main service closet was unavailable for entrance. Reason asking is ground and neutral were on same bus.
Reply With Quote
FREA Home Inspector Insurance
  #2 (permalink)  
Old 07-29-2008, 06:17 PM
John Arnold John Arnold is online now
Member
 
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 2,036
Re: Condo elec SERVICE
Quote:
Originally Posted by Ross Neag View Post
On a condo panel that has NO MAIN, is it service or a subpanel (50 unit bldg)? Main service closet was unavailable for entrance. Reason asking is ground and neutral were on same bus.
Ross - Most of the condo panels I see have no main, and often have no visible equipment grounds because they are not the service equipment panels (for god's sake, man, don't say subpanel around here!). So, most likely, the equipment grounds and the neutrals should be separated. The closet with the service equipment really should be accessible for the inspection. You want to be able to show the buyer where the main is, assuming there is one.
Reply With Quote
  #3 (permalink)  
Old 07-29-2008, 06:49 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: Condo elec SERVICE
Quote:
Originally Posted by Ross Neag View Post
On a condo panel that has NO MAIN, is it service or a subpanel
Neither.

It is not the service panel, nor is it a "subpanel" as there is no such thing.

It is a "distribution panel", or, if it is easier to remember, it is "not service equipment".

Quote:
Main service closet was unavailable for entrance.
Why? Locked? No one knew where it was?

Quote:
Reason asking is ground and neutral were on same bus.
Being as it is "not service equipment", the neutral is to be isolated from ground.

How do I *know* it is "not service equipment"? Because it is *one building* and *one building* does not allow for each of 50 units to have "service equipment" in them.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #4 (permalink)  
Old 07-29-2008, 08:42 PM
Ted Menelly Ted Menelly is online now
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 3,075
Re: Condo elec SERVICE
Jerry

A book says there is no sub panel or doesn't mention it or acknowledge it............and??????

The *terminology* sub panel has been in use for all of my living years and yours and everyone else alive.

Not looking for an argument by any means.

Sub Panel exists. It is just hiding from you because he knows you does not like it
__________________
Ted Menelly
Castle Home Inspection Services
www.inspectmycastle.com
Reply With Quote
  #5 (permalink)  
Old 07-29-2008, 10:33 PM
Brandon Chew Brandon Chew is offline
Member
 
Join Date: Mar 2007
Location: Albany, NY
Posts: 301
Re: Condo elec SERVICE
You'll find sub panels on submarines. You won't find them in the NEC or the IRC.
Reply With Quote
  #6 (permalink)  
Old 07-30-2008, 07:11 AM
Markus Keller Markus Keller is offline
Member
 
Join Date: Feb 2008
Location: Chicago IL
Posts: 779
Re: Condo elec SERVICE
You may want to consider mentioning to the agent ahead of time that you want to see the meter room, it cuts down on the excuses. I always want to see it to take a look and show the client where it is also.
Chicago code varies a bit depending on circumstances. Essentially, if the disconnect is in the meter room then owners/tenants have to have access to it.
If there is an onsite full-time engineer or it has exterior access only then it's a little different. Usually around here though it's in the basement, which means owners need access.
__________________
Accurate Inspections & Consulting, Inc.
773/844-4AIC
"The Code is not a ceiling to reach but a floor to work up from"
Reply With Quote
  #7 (permalink)  
Old 07-30-2008, 08:27 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: Condo elec SERVICE
Quote:
Originally Posted by Markus Keller View Post
Chicago code varies a bit depending on circumstances. Essentially, if the disconnect is in the meter room then owners/tenants have to have access to it.
If there is an onsite full-time engineer or it has exterior access only then it's a little different. Usually around here though it's in the basement, which means owners need access.
Marcus,

That's also in the NEC.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
IC Home Inspection Report Writing
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Seperate service to outbuilding serves circuits in main building with own service ... Michael Thomas Electrical Systems: Home Inspection and Commercial Inspection 3 02-17-2008 07:44 AM
Condo Inspections David Banks General Chit Chat: Home Inspectors & Commercial Inspectors 5 11-02-2007 06:46 AM
Elec box questions Rick Maday Electrical Systems: Home Inspection and Commercial Inspection 3 09-08-2007 11:30 AM
Service conduit bonding at service equipment Michael Thomas Electrical Systems: Home Inspection and Commercial Inspection 0 08-07-2007 06:59 AM
condo panel box william siegel Electrical Systems: Home Inspection and Commercial Inspection 10 04-26-2007 08:40 AM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 02:13 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger