You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 05-08-2007, 10:52 AM
dan orourke dan orourke is offline
Member
 
Join Date: Mar 2007
Location: dust in the wind
Posts: 157
Light fixture location - stairway
..............

Last edited by dan orourke : 01-02-2008 at 09:20 AM.
Reply With Quote
  #2 (permalink)  
Old 05-08-2007, 03:54 PM
Tim Moreira's Avatar
Tim Moreira Tim Moreira is offline
Member
 
Join Date: Mar 2007
Location: New Port Richey, Fl
Posts: 446
Re: Light fixture location - stairway
Dan,

From the 03 IRC:

R 311.5 Stairways.

311.5.2 Headroom.
The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches (2036 mm) measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.

311.5.7 Illumination.
All stairs shall be provided with illumination in accordance with Section R303.6.


303.6 Stairway illumination.
All interior and exterior stairways shall be provided with a means to illuminate the stairs, including the landings and treads. Interior stairways shall be provided with an artificial light source located in the immediate vicinity of each landing of the stairway. For interior stairs the artificial light sources shall be capable of illuminating treads and landings to levels not less than 1 foot-candles (11 lux) measured at the center of treads and landings. Exterior stairways shall be provided with an artificial light source located in the immediate vicinity of the top landing of the stairway. Exterior stairways providing access to a basement from the outside grade level shall be provided with an artificial light source located in the immediate vicinity of the bottom landing of the stairway.



I would not comment on it as long as it did not intrude on the 6'8" headroom space.

Folks carrying large objects just need to watch there surrounding
Reply With Quote
Are inspection referrals from past clients important to you?
If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Light switch location Jeff Eastman Electrical Systems: Home Inspection and Commercial Inspection 8 04-19-2007 12:57 PM
Light switch position. Jeff Eastman Electrical Systems: Home Inspection and Commercial Inspection 4 04-18-2007 07:03 PM
light bulb beats pvc John Arnold Plumbing System: Home Inspection and Commercial Inspection 7 04-16-2007 02:46 PM
Stairway Illumination dan orourke Building Interior: Home Inspection and Commercial Inspection 4 04-15-2007 06:46 PM
From the old board, Stairway windows? Tim Moreira Building Interior: Home Inspection and Commercial Inspection 1 04-04-2007 12:03 PM


All times are GMT -7. The time now is 02:55 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger