Registration is FREE!... and will get rid of this top message
Welcome to InspectionNews.net.
You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.
There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.
Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!
Registration is FREE, fast and easy so please, join InspectionNews today!
Why join InspectionNews? Read the Testimonials
Looking for Education? We recommend Casey, O'Malley and Associates

If you have any problems with the registration process or your account login, please contact us.
|
|

09-26-2009, 09:10 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Miami, Florida
Posts: 182
|
|
|
Chinese drywall help needed
Need some input from you guys.
I did a 2002 house today. The whole house had a smell to it, but it was not a sulfur smell. It was really hard to describe. It almost smelled like wet dogs (no joke) throughout the whole house.
The copper lines running to the air handler were black. The air conditioning system was replaced in 2006 and was icing up, both at the air handler and the condenser unit.
I pulled off outlet covers in the kitchen - copper wires were fine.
I pulled off outlet covers in the utility room (where the air handler was) and the ground wire was black.
I pulled of outlet covers in the master bathroom, which is on the same side of the home as the air handler, and the ground wires were black.
I did not pull any more covers.
The distribution panel was in the garage. All the wires looked normal.
The wate heater was leaking at the elements, but the copper was fine.
I suspect that this is from Chinese Drywall from my findings. Of course the buyers realtor thought otherwise.
I have indicated in my report that there are indicators that the home has Chinese Drywall and that testing is necessary. I also indicated that if those tests come back negative that they still need to test to determine the cause of the odor.
My quesiton is this:
Where does my liability stand for this? If there is no Chinese drywall, can the builder (the seller is the bank) come after me. Does anyone have any verbage that they would use in this situation. Believe me - I am 95% certain that I am right. The age of the home is slightly before all the hoopla came out, and I am just looking for thoughts and ideas. My report will stand - i would just like some feedback from those of you in the trenches.
__________________
Bill Siegel
Florida Home Inspection Team Inc.
|
|

09-26-2009, 09:26 PM
|
 |
Member
|
|
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
|
|
|
Re: Chinese drywall help needed
Bill,
Why use Chinese Drywall wording at all ?
Just Report what you saw and smelled.
.
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
|
|

09-26-2009, 09:34 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Miami, Florida
Posts: 182
|
|
|
Re: Chinese drywall help needed
Billy,
Because I believe that I should recommend something. Besides, what I saw leads me to the conclusion that it is Chinese Drywall. Isnt our job to give our opinion and make reccomendations??
__________________
Bill Siegel
Florida Home Inspection Team Inc.
|
|

09-26-2009, 09:44 PM
|
 |
Member
|
|
Join Date: Jul 2008
Location: Snowbird, FL/MI
Posts: 510
|
|
|
Re: Chinese drywall help needed
Were there laundry facilities in the utility room?
Point being there are other possiblities besides Chinese Drywall that can lead to blackening of copper.
Sulfur odors aren't often mistaken for "wet dog" smells. Ammonia plus cigarette smoke residue often is.
Drawing a conclusion as you have might not be prudent. Reporting observations and smells and recommending further investigation may be wiser.
|
|

09-26-2009, 09:46 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,293
|
|
|
Re: Chinese drywall help needed
Originally Posted by william siegel
I have indicated in my report that there are indicators that the home has Chinese Drywall and that testing is necessary. I also indicated that if those tests come back negative that they still need to test to determine the cause of the odor.
Bill,
I would report all the evidence you found which indicates that Chinese drywall *MAY* ... that is key, "may" ... be present, and then do as you said - recommend testing and additional investigation as to whether or not Chinese drywall is present.
What you describe almost indicates that there may be Chinese drywall installed in parts of the house but not in other parts of the house. I used to say that was unlikely as most drywall installers order the drywall from the same supplier, so it either was or was not, however, I now know that many suppliers carried several brands of drywall at the same time (instead of all one brand and switching during a contract change over) as they would buy from which ever source was the cheapest for each truckload ordered, which means there could be several brands of drywall in one house.
Which means that it is highly likely that Chinese drywall is mixed with non-Chinese drywall in the same house. It has happened in many, many cases.
I would be more concerned about NOT mentioning the *possibility* of Chinese drywall based on the evidence you found. After all, regarding the liability for mentioning it you are telling them to "verify it with further testing and investigation", and if they do not and Chinese drywall is present, it is the buyers problem, and if they do and Chinese drywall is present, it is the banks problem.
Likewise, if they do not and they do not buy the house, *YOU* *DID NOT* tell them *IT HAD* Chinese drywall, you said it *MAY* and that it needs to be checked out. If the bank elects *not to have it checked out*, as the bank likely will not (partially for fear of confirming it is Chinese drywall and partially because they do not want to spend the money), then it is the bank making the decision not to check it out and confirm that the drywall is not Chinese drywall.
You will be much more likely to get sued if you do not mention the possibility than if you do.
Anyone can sue anyone else for anything. So make sure you leave it at "may" and "possible". That is unless you looked in the walls and actually found Made in China on the back side of the drywall, and then you state that "some" Chinese drywall was present (which does not mean it is "all" Chinese drywall).
|
|

09-26-2009, 09:48 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Miami, Florida
Posts: 182
|
|
|
Re: Chinese drywall help needed
Interesting thoughts.
Washer and dryer have been removed and the water heater is electric.
The replacement of the air handler in 2006 seems to be my biggest clue.
The smell could also be somewhat nuetralilzed because the air conditioner was running, although not very well.
__________________
Bill Siegel
Florida Home Inspection Team Inc.
|
|

09-26-2009, 09:50 PM
|
 |
Member
|
|
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
|
|
|
Re: Chinese drywall help needed
Originally Posted by william siegel
Billy,
Because I believe that I should recommend something. Besides, what I saw leads me to the conclusion that it is Chinese Drywall. Isnt our job to give our opinion and make reccomendations??
.
Recommend finding the cause of the damaged wiring and of the Smell noted.
" Similar conditions have been noted in homes constructed with drywall containing sulfur and imported from China." ( if you must.)
Doesn't Florida have a Government web site dedicated to " The Dreaded Chinese Drywall Issue?"
* your first Post was a Question concerning Liability if No Chinese Drywall was found ( after I presume a form of Destructive Testing was Performed.)
.
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
|
|

09-26-2009, 09:53 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Miami, Florida
Posts: 182
|
|
|
Re: Chinese drywall help needed
Jerry,
Looks like we are on the same page. This is actually what I have written so far:
During the inspection we found the following indicators that are signs of Chinese Drywall:
1. There was an odor in the home. It is difficult to describe the odor. It did not have the smell of rotten eggs, but was consistent and the whole interior of the home had the same smell.
2. The air handler and condenser unit were replaced in 2006, after 4 years of use. Failing systems are also an indicator of Chinese drywall.
3. The liquid copper line to the air handler was black.
4. We removed the outlet covers in the laundry room and in the master bathroom and the copper ground wires have turned black.
We recommend that environmental testing be conducted on this home. Chinese drywall should be one focus of the testing. If testing proves negative for Chinese drywall, other testing should be done to determine the cause of the smell in the home.
Note: One other way to determine if Chinese drywall is present is to remove sheets of drywall and read the markings on the back of the drywall. The tainted drywall has specific markings that will identify it.
Any testing or removal of drywall should be done by the builder or owner of the home.
__________________
Bill Siegel
Florida Home Inspection Team Inc.
|
|

09-26-2009, 10:03 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,293
|
|
|
Re: Chinese drywall help needed
Originally Posted by william siegel
Note: One other way to determine if Chinese drywall is present is to remove sheets of drywall and read the markings on the back of the drywall. The tainted drywall has specific markings that will identify it.
Any testing or removal of drywall should be done by the builder or owner of the home.
Another way to tell is to drill / cut a hole in the top plate and look down into the walls with a camera, you can see the labeling without cutting large sections out of the drywall. Or, cut small holes in near the top of the wall and send the camera in those holes, leaving smallish holes to repair.
The first and easiest place to look is to remove a recessed-in-the-wall bathroom medicine cabinet, usually only 2 to 4 screws, that will let you look right down into the wall, usually where you will see some labeling and even edge tape.
|
|

09-26-2009, 10:11 PM
|
 |
Member
|
|
Join Date: Jul 2008
Location: Snowbird, FL/MI
Posts: 510
|
|
|
Re: Chinese drywall help needed
Another possiblity is cupric oxide, which is highly resistant. This can occur from super heating copper (for example letting a copper pot boil dry on an electric stove element or lightening strike).
Refrigerant leaks in in-use laundry areas can also cause copper discoloration.
Certainly the blackening electrical wiring is suspect and needs to be investigated. It is unfortunate the laundry machines have been removed - they too (especially an electric dryer plug) may have provided more clues.
|
|

09-27-2009, 05:45 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: South Florida
Posts: 225
|
|
|
Re: Chinese drywall help needed
Bill,
An easy way to determine if Chinese Drywall is present is to move the insulation in the attic and look for stickers. Although this is not 100% accurate, it could help you positively identify the drywall if the Knauff labels are found.
I would certainly mention the symptoms you found and make a recommendation for further evaluation. I don't know if you know this or not, but, it is my understanding that as soon as the Chinese Drywall story broke, almost every Realty company added a disclaimer to their contracts.
I have added a disclaimer to my reports as well excluding Chinese Drywall, unless, a specific inspection was done for it.
Just because you don't find it, doesn't mean that it isn't there, either. One house I inspected had three different manufacturers and three different date codes, and that was just the attic drywall!
One other thing, as numerous builders have gone out of business, if Chinese Drywall is discovered in a home, the homeowner is stuck with it. I would suggest that all inspectors be very careful regarding this issue.
__________________
Eric Van De Ven Magnum Inspections Inc. (954) 340-6615
www.magnuminspections.com
I still get paid to be suspicious when I got nothing to be suspicious about!
|
|

09-27-2009, 06:56 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Miami, Florida
Posts: 182
|
|
|
Re: Chinese drywall help needed
Eric,
I actually have a diclaimer that I use on every home built after 2000 not. It is a separate one page document. If they will not sign it, I will not do the inspection.
FYI to all the inspectcors out there: an inspector that I know is beign sued for not mentioning chinese drywall, and his inspection was done about two months before all of the stories broke on the issue. The blame game is only just begining.
__________________
Bill Siegel
Florida Home Inspection Team Inc.
|
|

09-27-2009, 07:01 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: South Florida
Posts: 225
|
|
|
Re: Chinese drywall help needed
Bill,
I might think about rewording the disclaimer and making it for ALL inspections. You never know if someone had to do repairs and may have used Chinese Drywall and didn't know it.
__________________
Eric Van De Ven Magnum Inspections Inc. (954) 340-6615
www.magnuminspections.com
I still get paid to be suspicious when I got nothing to be suspicious about!
|
|

09-27-2009, 07:05 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Miami, Florida
Posts: 182
|
|
|
Re: Chinese drywall help needed
Excellent point.
__________________
Bill Siegel
Florida Home Inspection Team Inc.
|
|

09-27-2009, 08:03 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,293
|
|
|
Re: Chinese drywall help needed
Originally Posted by Eric Van De Ven
An easy way to determine if Chinese Drywall is present is to move the insulation in the attic and look for stickers. Although this is not 100% accurate, it could help you positively identify the drywall if the Knauff labels are found.
Eric,
I have found many homes which had National Gypsum (or some other domestic brand) drywall on the ceiling, but then had Chinese drywall elsewhere.
Yes, if you find Chinese drywall in the attic (an easy place to look), then you have found Chinese drywall installed in at least some locations.
No, if you do not find Chinese drywall in the attic it is not any indication of any type that there may not be Chinese drywall elsewhere.
|
|

09-27-2009, 09:19 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,796
|
|
|
Re: Chinese drywall help needed
It does sound like "problematic" drywayll is in the home. I say problematic, because it might not be from China, other brands and manufactuters might have produced tainted drywall as well.
|
|

09-27-2009, 09:26 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: South Florida
Posts: 225
|
|
|
Re: Chinese drywall help needed
Jerry,
I agree with you on the fact that there may be Chinese Drywall elsewhere. If you looked in all of the areas you could, removing the medicine cabinet, cover plate for the washing machine, etc., you would still be limited to the areas that you could see.
The only way to know for sure, would be to examine every piece of drywall. How much should we charge for that? LOL
It is why I think that every inspector should take this seriously. It isn't limited to Florida.
__________________
Eric Van De Ven Magnum Inspections Inc. (954) 340-6615
www.magnuminspections.com
I still get paid to be suspicious when I got nothing to be suspicious about!
|
|

09-27-2009, 09:51 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,796
|
|
|
Re: Chinese drywall help needed
Originally Posted by Eric Van De Ven
Jerry,
It is why I think that every inspector should take this seriously. It isn't limited to Florida.
This is so true! It was just the first place it reared it's ugly head! Arid areas might not see it for who knows how long...... It needs humidity as the trigger to start the chemical reaction.
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| How to test for chinese drywall |
Mark Beckerman |
Building Interior: Home Inspection and Commercial Inspection |
99 |
11-19-2009 05:21 AM |
| Help with Chinese drywall inspections |
Mark Beckerman |
Building Interior: Home Inspection and Commercial Inspection |
45 |
06-09-2009 10:48 AM |
| Chinese Drywall |
Stephen Meyer |
Building Interior: Home Inspection and Commercial Inspection |
16 |
05-15-2009 04:19 PM |
| Chinese drywall |
John Arnold |
Building Interior: Home Inspection and Commercial Inspection |
43 |
05-04-2009 05:16 PM |
| Chinese Drywall - Experiment? |
John Jeffries |
Building Interior: Home Inspection and Commercial Inspection |
34 |
05-04-2009 10:49 AM |
All times are GMT -7. The time now is 06:50 AM.
| | |
|