You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 11-26-2007, 11:11 AM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,155
Sic transite gloria mundi
First picture is a heating duct in a floor slab seen from above through a floor register in a circa 1950s ranch.

Second picture is a detail of a picture of a different duct identified as "Transite" at:

http://www.inspect-ny.com/aircond/du...teHeatDuct.jpg

Pretty similar, eh?

On that basis I reported it as possible asbestos containing material.

Went out there today and met the client's HVAC contractor WRT other issues.

Also, brought along my wife's tiny Kodak camera, which was small enough to get past the narrow register opening and operate once I got it down into the duct.

That's the next three pictures.

HVAC guy says: "Only way to know for sure is to have it tested, but that's NOT Transite, that's clay tile. Almost never see that, everything in a slab that age around here is either Transite or formed concrete concrete. I've seen it maybe once or twice. But you can see the brown glaze color, the sections are only 2' long (Transite came in 10' lengths, and is gray), and you can see the clay tile in cross-section in the pictures."

Client will get it tested to be sure, but of course is happy.

I of course am somewhat chagrined.

Last edited by Michael Thomas : 11-26-2007 at 04:53 PM.
Reply With Quote
  #2 (permalink)  
Old 11-26-2007, 04:43 PM
Gunnar Alquist's Avatar
Gunnar Alquist Gunnar Alquist is offline
Member
 
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 747
Re: Sic transite gloria mundi
From the pics, it looks like terra cotta. At least to me. I was not there, so you are the best judge.
__________________
The apostrophe troll.
Reply With Quote
  #3 (permalink)  
Old 11-26-2007, 04:51 PM
Jim Luttrall Jim Luttrall is offline
Member
 
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,579
Re: Sic transite gloria mundi
Quote:
I of course am somewhat chagrined.
Why? You reported what you saw and I will bet you would do the same thing in the next similar circumstance. Even the HVAC guy hedged his bet by mentioning testing is "the only way to know for sure".
No need for any embarrassment in my book.
Be happy for your client. It still looks like there are some issues with those ducts.
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
Reply With Quote
  #4 (permalink)  
Old 11-26-2007, 05:05 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,155
Re: Sic transite gloria mundi
Gunnar,

Now that I've seen the inside of the ducts, I'm 99.9% sure the HVAC guy has it right.

The reason I was looking at that inspect-ny pic in the first place is that all the Transite I've seen is "gray", but this was a brown, unglazed material. If you look at the first two pics the interior of the duct at the inspection is an almost exact visual match for the "Transite" material in the reference pic, and on that basis I identified it as "similar to" in the report.

Now, I'm wondering abut the ID of the reference material itself.

In any case my objective in positing was to alert others to the possibility of clay tile heating ducts in floor slabs - I'd never seen this before.

Jim,

I reported what I saw correctly - I just wish I had been a bit more skeptical (at least to myself) about that inspect-ny identification.

Last edited by Michael Thomas : 11-26-2007 at 07:39 PM.
Reply With Quote
  #5 (permalink)  
Old 11-26-2007, 06:02 PM
Gunnar Alquist's Avatar
Gunnar Alquist Gunnar Alquist is offline
Member
 
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 747
Re: Sic transite gloria mundi
Michael,

Yes, I agree. I have never run into terra cotta ducting either. Pretty weird. I understand your embarrassment, but it is a minor error. Not sure that I would not have done something similar. (even though I didn't)
__________________
The apostrophe troll.
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT -7. The time now is 03:16 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger