Chimney Chase
I am no copper worker, but I would appreciate your thoughts on this.
Mat
Similar Threads:
-
06-25-2009, 09:09 PM #2
Re: Chimney Chase
It is a temporary patch, repair required.
-
06-25-2009, 09:14 PM #3
Re: Chimney Chase
Looks like a get-er-close, tape-er-up to me
-
06-26-2009, 06:08 AM #4
Re: Chimney Chase
Is that a chimney vent termination for a gas fireplace?
If so, there is no storm collar, and the decorative shroud is not allowed unless listed for that use (Bob H. taught us that, I often wondered about it before that).
-
06-26-2009, 06:42 AM #5
Re: Chimney Chase
Jerry,
It is for a wood fireplace and there is a flue next to it for a gas fireplace.
-
06-26-2009, 07:16 AM #6
Re: Chimney Chase
Mat,
The one in the photo is not for the wood fireplace is it?
-
06-26-2009, 07:24 AM #7
Re: Chimney Chase
It looks like the outer pipe is too short and the storm collar won't fit the smaller inner pipe so they used tape and painted over it.
No matter, it is wrong and needs to be fixed.
Probably the only thing saving it from leaking like a sieve is the outer cover which, as Jerry mentioned, may not be allowed.
-
06-26-2009, 09:35 AM #8
Re: Chimney Chase
Jerry, It is for a wood fire place, you can see the soot on the arestor.