Results 1 to 3 of 3
  1. #1
    Jon mackay's Avatar
    Jon mackay Guest

    Default Chimney screened cap with capped liner below

    The gas fireplace installed had some back drafting at start-up and some minor scorching.
    I was wondering if the scenario in the picture would contribute to that and if it is even allowed.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Crawl Space Creeper

  2. #2
    Join Date
    Mar 2007
    Location
    Near Philly, Pa.
    Posts
    1,682

    Cool Re: Chimney screened cap with capped liner below

    Looks like a B-vented (single 4" aluminum liner) vented gas insert with an illegal unlisted shroud.

    Good catch Jon!

    Need to remove shroud, level II, service by qualified gas pro and depressurization testing with combustion analysis.

    Keep the fire in the fireplace.

  3. #3
    Jon mackay's Avatar
    Jon mackay Guest

    Default Re: Chimney screened cap with capped liner below

    Thank you Bob.