Gas supply lines for gas log fireplace
Just ran into this yesterday. Heat-n-glo gas log unit installed in the corner of a basement.
Two flex lines joined together from steel gas pipe are supplying the unit. Wasn't sure how to call or phrase this defect. Any suggestions?
Similar Threads:Last edited by Ron Poteet; 04-08-2011 at 02:18 AM. Reason: mispelled word
-
04-08-2011, 03:03 AM #2
Re: Gas supply lines for gas log fireplace
IRC G2422.1.2.1 (411.1.3.1) Maximum length. Connectors shall have an overall length not to exceed 3 feet (914 mm), except for range and domestic clothes dryer connectors, which shall not exceed 6 feet (1829 mm) in overall length. Measurement shall be made along the centerline of the connector. Only one connector shall be used for each appliance.